Middle Atlantic Uninterruptible Power Supply
Rack Mountable UPS With USB Connection Port, Surge Protection, and Expansion Battery Ports
MA-UPS-1000R
What's special about this rack mountable UPS?
- Fast transfer rate for less down time on your servers, monitors, or patch panels.
- This UPS conserves energy buy using only 9W at full capacity, which means that it consumes 75% less power to help you save money on your electric bill.
- Compact design will only take up 2U, leaving plenty of room for the rest of your equipment.
- Click for More Features
-
If you are environmentally conscious and would like to leave a smaller footprint on our planet, then this uninterruptible power supply with Energy Saver design is for you. This UPS reduces power consumption by up to 75%, compared to other models.
Part # | Description | Dimensions | Weight | Price |
---|---|---|---|---|
MA-UPS-1000R | 1000 VA, 750 Watt Rackmount UPS | 2U x 19" W x 19-32" D | 68 lbs | Manufacturer Direct
|
MA-UPS-2200R | 2150 VA, 1650 Watt Rackmount UPS | 2U x 19" W x 19-32" D | 77 lbs | Manufacturer Direct
|
Accessories | ||||
---|---|---|---|---|
Part # | Description | Dimensions | Weight | Price |
MA-UPS-EBPR | UPS Expansion Battery Pack | 2U x 19" W x 19-32" D | 70 lbs | Manufacturer Direct
|
MA-UPS-RBP | UPS Replacement Battery Pack | n/a | 32 lbs | Manufacturer Direct
|
Model No. | UPS-1000R | UPS-2200R |
---|---|---|
Standard runtime at Half load: | 26 minutes | 13 minutes |
Standard runtime at Full Load: | 13 minutes | 6 minutes |
Maximum runtime at Half Load: | 1196 minutes | 575 minutes |
Maximum runtime at Full Load: | 575 minutes | 200 minutes |
Input | ||
Nominal Input Voltage | 120 V | 120 V |
Input Voltage Range | 80Vac – 145Vac | 80Vac – 145Vac |
Input Frequency | 60 Hz ± 3 Hz (auto sensing) | 60 Hz ± 3 Hz (auto sensing) |
Input Protection Type | Resettable thermal fuse | Resettable thermal fuse |
Cord Length / Plug Type | 9 ft. / NEMA 5-15P | 9 ft. / NEMA 5-15P |
Output | ||
Green Mode Consumption | Less than 9W at full battery capacity | Less than 9W at full battery capacity |
Nominal Output Voltage | 120 V | 120 V |
Capacity (VA) | 1000VA | 2150VA |
Capacity (Watts) | 750W | 1650W |
Waveform | Pure Sine Wave | Pure Sine Wave |
On Line Output Frequency | 57 - 63 Hz for 60 Hz nominal | 57 - 63 Hz for 60 Hz nominal |
On Battery Output Frequency | 60 Hz ± 0.1 Hz | 60 Hz ± 0.1 Hz |
Transfer Time (Typical) | 4 ms typical line to battery / battery to line | 4 ms typical line to battery / battery to line |
100%≤ Load< 110% warning, 120 sec shutdown | 100%≤ Load< 110% warning, 120 sec shutdown | |
Overload Protection (on line mode) | 110%≤ Load< 125% warning, 40 sec shutdown | 110%≤ Load< 125% warning, 40 sec shutdown |
125%≤ Load warning, 10 sec shutdown | 125%≤ Load warning, 10 sec shutdown | |
100%≤ Load< 110% warning, 30 sec shutdown | 100%≤ Load< 110% warning, 30 sec shutdown | |
Overload Protection (on battery mode) | 110%≤ Load< 125% warning, 10 sec shutdown | 110%≤ Load< 125% warning, 10 sec shutdown |
125%≤ Load warning, 3 sec shutdown | 125%≤ Load warning, 3 sec shutdown | |
Surge Protection and Filtering | ||
Lightning / Surge Protection | L-N=>381 J (127J x 3) Clamp voltage 270V (Max energy 10 / 1000 μs) | L-N=>381 J (127J x 3) Clamp voltage 270V (Max energy 10 / 1000 μs) |
RJ11 / RJ45 Protection | Sidactorx1 Clamp Voltage 275V Fuse (0.75A / 250V) x 2 | Sidactorx1 Clamp Voltage 275V Fuse (0.75A / 250V) x 2 |
Physical | ||
Output Receptacles | (8) NEMA 5-15R | (8) NEMA 5-20R |
Dimensions (in.) | 19.00” [423] W x 3.50” [89] H x 19.29” [490] D | 19.00” [423] W x 3.50” [89] H x 19.29” [490] D |
Weight | 68 lbs. | 77 lbs. |
Battery | ||
Rating | 12V / 9.0 AH x 4 | 12V / 9.0 AH x 4 |
Auto Charger | 1A | 1A |
Hot Swappable External Battery | Yes | Yes |
Runtime at Half Load | 26 minutes | 13 minutes |
Runtime at Full Load | 13 minutes | 6.4 minutes |
Warning Diagnostics | ||
Control Panel | LCD Display Indicators, Power On | LCD Display Indicators, Power On |
Audible Alarms | On Battery, Low Battery | On Battery, Low Battery |
Environmental | ||
Operating Temperature | 32°F to 104°F ( 0°C to 40°C) | 32°F to 104°F ( 0°C to 40°C) |
Operating Relative Humidity | 0 to 95% Non-Condensing | 0 to 95% Non-Condensing |
Communication | ||
Software | Middle Atlantic Power Manager™ | Middle Atlantic Power Manager™ |
Management | ||
Self-Test | Manual Self-Test via front panel | Manual Self-Test via front panel |
Auto-Charger/ Auto-Restart | Yes | Yes |
COM Interface | ||
Primary: | - RS232 Communication + Control - Analog Status Notification + Control |
- RS232 Communication + Control - Analog Status Notification + Control |
Secondary: | - Analog status notification only | - Analog status notification only |
Built-in USB Interface | Yes | Yes |
Expansion Battery Estimated Runtimes
UPS-1000R | ||||||||
Load (VA) | 120 | 240 | 360 | 480 | 600 | 720 | 840 | 960 |
---|---|---|---|---|---|---|---|---|
Load (W) * | 84 | 168 | 252 | 336 | 420 | 504 | 588 | 672 |
Load (A) | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Number of expansion batteries | ESTIMATED RUNTIME (Minutes) | |||||||
UPS only | 102 | 51 | 34 | 26 | 20 | 17 | 15 | 13 |
1 | 561 | 283 | 190 | 143 | 114 | 94 | 80 | 69 |
2 | 1020 | 515 | 345 | 260 | 207 | 171 | 145 | 125 |
3 | 1479 | 747 | 501 | 377 | 300 | 249 | 211 | 181 |
4 | 1938 | 979 | 657 | 494 | 394 | 326 | 276 | 238 |
5 | 2397 | 1211 | 813 | 611 | 487 | 403 | 341 | 294 |
6 | 2856 | 1443 | 968 | 728 | 580 | 480 | 407 | 350 |
7 | 3315 | 1676 | 1124 | 845 | 674 | 557 | 472 | 406 |
8 | 3774 | 1908 | 1280 | 962 | 767 | 635 | 537 | 463 |
9 | 4233 | 2140 | 1435 | 1079 | 860 | 712 | 603 | 519 |
10 | 4692 | 2372 | 1591 | 1196 | 954 | 789 | 668 | 575 |
UPS-2200R | ||||||||||||||||
Load (VA) | 120 | 240 | 360 | 480 | 600 | 720 | 840 | 960 | 1080 | 1200 | 1320 | 1440 | 1560 | 1680 | 1800 | 1920 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Load (W) * | 90 | 180 | 270 | 360 | 450 | 540 | 630 | 720 | 810 | 900 | 990 | 1080 | 1170 | 1260 | 1350 | 1440 |
Load (A) | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Number of expansion batteries | ESTIMATED RUNTIME (Minutes) | |||||||||||||||
UPS only | 102 | 51 | 34 | 26 | 20 | 17 | 15 | 13 | 11 | 10 | 9 | 9 | 8 | 7 | 7 | 6 |
1 | 561 | 283 | 190 | 143 | 114 | 94 | 80 | 69 | 60 | 53 | 47 | 42 | 37 | 33 | 29 | 26 |
2 | 1020 | 515 | 345 | 260 | 207 | 171 | 145 | 125 | 109 | 96 | 84 | 75 | 66 | 58 | 51 | 45 |
3 | 1479 | 747 | 501 | 377 | 300 | 249 | 211 | 181 | 158 | 139 | 122 | 108 | 95 | 84 | 74 | 64 |
4 | 1938 | 979 | 657 | 494 | 394 | 326 | 276 | 238 | 207 | 181 | 160 | 141 | 124 | 109 | 96 | 84 |
5 | 2397 | 1211 | 813 | 611 | 487 | 403 | 341 | 294 | 256 | 224 | 197 | 174 | 153 | 135 | 118 | 103 |
6 | 2856 | 1443 | 968 | 728 | 580 | 480 | 407 | 350 | 305 | 267 | 235 | 207 | 182 | 161 | 141 | 122 |
7 | 3315 | 1676 | 1124 | 845 | 674 | 557 | 472 | 406 | 353 | 310 | 272 | 240 | 212 | 186 | 163 | 142 |
8 | 3774 | 1908 | 1280 | 962 | 767 | 635 | 537 | 463 | 402 | 352 | 310 | 273 | 241 | 212 | 185 | 161 |
9 | 4233 | 2140 | 1435 | 1079 | 860 | 712 | 603 | 519 | 451 | 395 | 348 | 306 | 270 | 237 | 208 | 181 |
10 | 4692 | 2372 | 1591 | 1196 | 954 | 789 | 668 | 575 | 500 | 438 | 385 | 339 | 299 | 263 | 230 | 200 |
* Assuming a Power Factor of 0.75