Tripp-Lite BC Professional UPS
Protect Every Size Computer from the Three D's: Downtime, Damage and Data Loss Incurred by Power Problems
What's special about this uninterruptible power supply?
- Protects your equipment and data from, blackouts, brownouts and line noise.
- Provides protection from power losses so your office systems and data are safe.
- USB port with PowerAlert monitoring software and cabling enables a safe, unattended system shutdown.
- Click for More Features
These UPS, or uninterrupted power systems, for desktop applications are available in a wide variety of protection capabilities to protect every size computer from the potentially catastrophic effects of downtime, damage and data loss which can occur due to power problems.
Part # | Description | Full Load Runtime | Half Load Runtime | Dimensions | Weight | Price |
---|---|---|---|---|---|---|
TL-BCPRO600 | Standby UPS with communications port |
5 min./ 600VA |
17 min./ 300VA |
10.75"H x 5.25"W x 7.25"D | 21 lbs. | Manufacturer Direct
|
TL-BCPRO1050 | Standby UPS | 7 min./ 1050VA |
23 min./ 525VA |
11.75"H x 7.25"W x 7.25"D | 30.5 lbs. | Manufacturer Direct
|
TL-BCPRO1400 | Standby UPS | 8 min./ 1400VA |
24 min./ 700VA |
12.75"H x 7.5"W x 9"D | 40 lbs. | Manufacturer Direct
|
The BC Pro UPS Systems offer complete protection against all types of power problems, including blackouts, brownouts, surges and line noise. In addition, they equip you with reliable battery power to keep computers up and running through short periods of power issues and allow enough time to safely shut down during longer ones.
Applications:
Model #: BCPRO600 - Standby UPS with communications port
Model #: BCPRO1050 - Standby UPS System
Model #: BCPRO1400 - Standby UPS System
Model #: TL-BCPRO600 | Model #: TL-BCPRO1050 | Model #: TL-BCPRO1400 | |
SYSTEM OVERVIEW | |||
---|---|---|---|
Voltage compatibility | 120VAC | 120VAC | 120VAC | Frequency compatibility | 60Hz | 60Hz | 60Hz |
OUTPUT | |||
Output VA | 350 | 300 | 450 |
Output watts | 180 | 180 | 280 |
Output nominal voltage | 120V AC | 120V AC | 120V AC (line mode) 115V AC (battery mode) |
Output voltage regulation- battery mode |
PWM sine wave output 120V ±5% | PWM sine wave output 115V ±5% | PWM sine wave 115V ±5% |
Output frequency regulation - line mode | 60Hz ±10% | 60Hz ±10% | 60Hz ±10% |
Output frequency regulation - battery mode | 60Hz ±0.5Hz | 60Hz ±0.5Hz | 60Hz ±0.5Hz |
Outlet quantity / type | 6 NEMA 5-15R | 6 NEMA 5-15R | 6 NEMA 5-15R |
INPUT | |||
Maximum input amps | 12A/1440W | 6.7A/760W | 9.2A/1030W |
Input connection type | NEMA 5-15P space saving right angle plug | NEMA 5-15P space saving right angle plug | NEMA 5-15P |
Input cord length | 6', 14 gauge | 6', 16 gauge | 6', 14 gauge |
Recommended Electrical Service | 15A 120V | 15A 120V | 15A 120V |
BATTERY | |||
Full load runtime | 5 min. (600VA) | 7 minutes (1050VA) | 8 minutes (1400VA) |
Half load runtime | 17 min. (300VA) | 23 minutes (525VA) | 24 minutes (700VA) |
DC system voltage | 12 VDC | 18 VDC | 36 VDC |
Typical battery lifespan | 3-6 years, depending on usage | 3-6 years, depending on usage | 3-6 years, depending on usage |
Battery recharge rate | 4.5 hours to 90% | 2-4 hours to 90% | 3.6 hours to 90% |
Replacement Battery Cartridge | RBC51 | RBC52 (3) | RBC53 |
LEDS ALARMS & SWITCHES | |||
Front panel LEDs | 3 front panel LEDs indicate line power status, battery power status and battery low/replace status | 5 front panel LEDs indicate line power status, battery power status, battery low/replace status, low/high input voltage detected and overload status | 5 front panel LEDs indicate line power status, battery power status, battery low/replace status, low/high input voltage detected and overload status |
Alarms | Audible alarm with 15 second delay sounds to indicate loss of utility power. Alarm can be silenced by pressing front panel alarm cancel button. Once silenced, alarm will re-sound when approximately 2 minutes runtime remain. | Audible alarm with 15 second delay sounds to indicate loss of utility power. Alarm can be silenced by pressing front panel alarm cancel button. Once silenced, alarm will re-sound when approximately 2 minutes runtime remain. | Audible alarm with 15 second delay sounds to indicate loss of utility power. Alarm can be silenced by pressing front panel alarm cancel button. Once silenced, alarm will re-sound when approximately 2 minutes runtime remain. |
Switches | Includes 2 front panel switches—one main on/off power switch and one dual function "alarm cancel" / "self test" button | Includes 2 front panel switches—one main on/off power switch and one dual function "alarm cancel" / "self test" button | Includes 2 front panel switches—one main on/off power switch and one dual function "alarm cancel" / "self test" button |
SURGE / NOISE SUPPRESSION | |||
AC surge suppression | 510 joules | 480 joules | 480 joules |
AC suppression response time | Instantaneous | Instantaneous | Instantaneous |
EMI / RFI AC noise suppression | Yes | yes | Yes |
Dataline suppression | Tel/DSL/Ethernet | - | - |
PHYSICAL | |||
Unit weight | 19 lbs. (8.6 kg) | 28.6 lbs. (13 kg) | 36.4 lbs. (16.5 kg) |
Unit dimensions | 10.75"H x 5.25"W x 7.25"D 27.3 H x 13.3 W x 18.4 D cm) |
11.75"H x 7.25"W x 7.25"D (29.8 H x 18.4 W x 18.4 D cm) |
12.75"H x 7.5"W x 9"D (32.4 H x 19.1 W x 22.9 D cm) |
Material of construction | PVC | Polycarbonate | PVC |
Form factors supported | Tower | Tower | Tower |
Cooling method | Convection | Convection | Convection |
Battery access | Built-in battery access door. Hot-swappable battery replacement supported. | Built-in battery access door | Built-in battery access door. |
ENVIRONMENTAL | |||
Operating Temperature | 32°F - 104°F (0°C - 40°C) | 32°F - 104°F (0°C - 40°C) | 32°F - 104°F (0°C - 40°C) |
Storage Temperature | 5°F - 122°F (-15°C - 50°C) | 5°F - 122°F (-15°C - 50°C) | 5°F - 122°F (-15°C - 50°C) |
Relative Humidity | 0 to 95%, non-condensing | 0 to 95%, non-condensing | 0 to 95%, non-condensing |
COMMUNICATIONS | |||
Network monitoring port | USB (HID) | USB | USB |
Software and cabling included | PowerAlert software available for free download at www.tripplite.com, includes USB cable | PowerAlert software available for free download at www.tripplite.com, includes USB cable | PowerAlert software available for free download at www.tripplite.com, includes USB cable. |
WatchDog System Service compatibility | Yes, to restore operation to locked equipment through soft reboot of application/OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications | Yes, to restore operation to locked equipment through soft reboot of application/OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications | Yes, to restore operation to locked equipment through soft reboot of application/OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications |
LINE / BATTERY TRANSFER | |||
Transfer time from line power to battery mode | 2-4 milliseconds | 2-4 milliseconds | 2-4 milliseconds |
Low voltage transfer to battery power | Switches to battery power as line voltage decreases to 99 volts or less. Resets to line power mode as line voltage increases to 104V or higher. Back panel potentiometer allows users to adjust brownout response to any voltage between 83 and the 99 volt factory preset. | Switches to battery power as line voltage decreases to 99 volts or less. Resets back to line power mode as line voltage increases to 104V or higher. | Switches to battery power as line voltage decreases to 99 volts or less. Resets back to line power mode as line voltage increases to 104V or higher. |
High voltage transfer to battery power | Yes | Yes | Yes |
SPECIAL FEATURES | |||
Cold Start | Can be "cold started" to enable temporary AC output during a power failure | Can be "cold started" to enable temporary AC output during a power failure | Can be "cold started" to enable temporary AC output during a power failure |
CERTIFICATIONS | |||
Certifications | UL1778, CSA C22.2 No. 107.3, Class B (Emissions), NOM (Mexico)FCC Part 68 / Industry Canada (telecommunications), RoHS compliant | UL1778, CSA C22.2 No. 107.3, Class B (Emissions), NOM (Mexico) | UL1778, CSA C22.2 No. 107.3, Class B (Emissions), NOM (Mexico) |
WARRANTY | |||
Manufacturer's product warranty | 2-year | 2-year | 2-year |
Connected equipment insurance | $200,000 (USA, Puerto Rico, and Canada only) | $200,000 (USA, Puerto Rico, and Canada only) | $200,000 (USA, Puerto Rico, and Canada only) |
Manuals
Related Articles
How-To Corner
Request A Quote
Did you know that we can give you a quote for most of our products, including shipping?
You can also call us toll free 1-833-3CABLEORG (1-833-322-2536)
Questions & Answers
Do you have any questions about this product?
Let our experts and customers resolve all your doubts