Home > Power/Data Distribution > Power Distribution Strips > AC/DC Power Distribution Panels
AC/DC Power Distribution Panels for a Precise Power Distribution Network
Designed for standard EIA, RS310 19" Racks and Cabinets
15 AMP & 20 AMP. Current monitoring - BRC and SPC Units
- 15 Amp or 20 Amp units
- Surge suppressed or non-surge units
- Ten 20 Amp receptacles (5-20R)
*Surge Suppressed Units (SP series) are UL tested and Recognized 1449, 330V Rating, 720 Joules.
| NEMA 5-15 | NEMA 5-20 | NEMA Twist Lock | |
| Receptacles | ![]() |
![]() |
![]() |
| Plugs | ![]() |
![]() |
![]() |
*Please note that all items on this page are subject to a manufacturer's restocking fee equal to 50% of the purchase price if returned for any reason other than product defects. To avoid returns and the restocking fee, please be sure to double check each product's configuration and specs to ensure that they meet your specific needs. Have questions before you order? Just call us toll-free at 866-222-0030, and we'll be happy to help you out!
Note: There is a two week lead time on all items on this page
| 19" Horizontal Power Distribution |
Part # | Description | Price |
| PD-BR120-10 | 12 outlets - 2 front, 10 rear (6 duplexes). 15 AMP Non Surge. For Specifications click here |
||
| PD-BR120-1020 | 12 outlets - 2 front, 10 rear (6 duplex 15 amp receptacles). 20 Amp Non-Surge. For Specifications click here |
||
| PD-SP124-10 | 12 outlets - 2 front, 10 rear (6 duplexes). 15 AMP Surge. For Specifications click here |
||
| PD-SP124-1020 | 12 outlets - 2 front, 10 rear (6 duplex 15 amp receptacles). 20 AMP Surge. For Specifications click here |
||
| PD-BR100-10 | 10 outlets on rear (5 duplexes). 15 AMP Non Surge. For Specifications click here |
||
| PD-BR100-1020 | 10 outlets on rear (5 duplex 15 amp receptacles). 20 AMP Non Surge. For Specifications click here |
||
| PD-SP104-10 | 10 outlets on rear (5 duplexes). 15 AMP Surge. For Specifications click here |
||
| PD-SP104-1020 | 10 outlets on rear (5 duplex 15 amp receptacles). 20 AMP Surge. For Specifications click here |
||
![]() |
PD-BRF100-10 | 10 outlets on front (5 duplexes) with recessed housing. 15 AMP Non Surge. For Specifications click here |
|
| PD-BRF100-1020 | 10 outlets on front (5 duplex 15 amp receptacles) with recessed housing. 20 AMP Non Surge. For Specifications click here |
||
| PD-SPF104-10 | 10 outlets on front (5 duplexes) with recessed housing. 15 AMP Surge. For Specifications click here |
||
| PD-SPF104-1020 | 10 outlets on front (5 duplex 15 amp receptacles) with recessed housing. 20 AMP Surge. For Specifications click here |
||
| PD-BRC100-10 | 10 outlets on rear (5 duplexes), Digital Current Meter. 15 AMP Non Surge. For Specifications click here |
||
| PD-BRC100-1020 | 10 outlets on rear (5 duplex 15 amp receptacles), Digital Current Meter. 20 AMP Non Surge. For Specifications click here |
||
| PD-SPC104-10 | 10 outlets on rear (5 duplexes), Digital Current Meter. 15 AMP Surge. For Specifications click here |
||
| PD-SPC104-1020 | 10 outlets on rear (5 duplex 15 amp receptacles), Digital Current Meter. 20 AMP Surge. For Specifications click here |
||
| PD-BR060-10 | 6 outlets on rear (3 duplexes). 15 AMP Non Surge. For Specifications click here |
||
| PD-BR060-1020 | 6 outlets on rear (3 duplex 15 amp receptacles). 20 AMP Non Surge. For Specifications click here |
||
| PD-SP064-10 | 6 outlets on rear (3 duplexes). 15 AMP Surge. For Specifications click here |
||
| PD-SP064-1020 | 6 outlets on rear (3 duplex 15 amp receptacles). 20 AMP Surge. For Specifications click here |
||
![]() |
PD-BRF060-10 | 6 outlets on front (3 duplexes) with recessed housing. 15 AMP Non Surge. For Specifications click here |
|
| PD-BRF060-1020 | 6 outlets on front (3 duplex 15 amp receptacles) with recessed housing. 20 AMP Non Surge. For Specifications click here |
||
| PD-SPF064-10 | 6 outlets on front (3 duplexes) with recessed housing. 15 AMP Surge. For Specifications click here |
||
| PD-SPF064-1020 | 6 outlets on front (3 duplex 15 amp receptacles) with recessed housing. 20 AMP Surge. For Specifications click here |
||
| PD-BRT060-10 | 6 ninety degree, transformer spaced outlets on rear (6 individual). 15 AMP Non Surge. For Specifications click here |
||
| PD-SPT064-10 | 6 ninety degree, transformer spaced outlets on rear (6 individual). 15 AMP Surge. For Specifications click here |
||
| PD-BRX080-10 | 8 ninety degree, transformer spaced outlets - 4 front, 4 rear (8 individual). 15 AMP Non Surge. For Specifications click here |
||
| PD-SPX084-10 | 8 ninety degree, transformer spaced outlets - 4 front, 4 rear (8 individual). 15 AMP Surge. For Specifications click here |
||
| PD-2VRELN160-103C13TL6 | Zone Power Strip. 30 Amps, 250 Volt, 16 IEC320 receptacles For Specifications click here |
For your convenience, we have compiled some of the most frequently-asked questions about our unique power distribution unit single phase solutions for the best in power distribution network systems. Let our power distribution blocks work for your electrical needs.
How many Amps am I drawing?
BRC/SPC feature Current Monitoring with a real time digital readout. Read amperage as each device is connected.
My transformers block outlets and extend beyond the front of my cabinet
BRX/SPX or BRT/SPT feature individual 90° receptacles. BRX/SPX feature a 2½" recessed housing with front and rear receptacles.
I can't see the rating of my power unit once it is installed
15A and 20A units contain highly visible breakers with the amperage rating of the unit embossed on the reset button.
I need to mount my power unit without sacrificing "U" space
BRX/SPX , BRF/SPF , MB , and BRD units all feature optional reversible recess mount (-RM), flush mount (-FM) or panel mount (-PM) brackets.
Breakers located on the bottom of my power strip are not viewable or easily accessible for reset
Highly visible circuit breakers are located on the face of our units, easily accessible and resettable if tripped.
What You Need - Modify to Meet Your Needs
Geist’s Vertical and Horizontal Power Distribution Units are designed,tested and manufactured in the USA. Over 1000 model numbers available,to meet your application needs.
Configurations & Options
- NEMA and IEC
- 125V, 250V, 125/250V and 120/208V WYE
- 15 Amp, 20 Amp, 30 Amp, 40 Amp (2 circuits @ 20 Amp) and 60 Amp
- Surge and Non-Surge
- IP Addressable
- Digital Current Monitoring
- Auto A/B Transfer Switching
- Multiple Circuits
- On/Off Power Switches – Optional on most units
- Straight Blade Plugs, Twist-Lock Plugs and Hardwired Connections
- Cord Length Options from 2’ to 25’
- Numerous Mounting Options – Including Zero "U"
Additional Terminology and Fast Facts:
- The joule rating of a surge suppressor is a measurement of its capacity to dissipate surge energy. The higher the joule rating, the better the protection.
- The clamping voltage rating of a surge suppressor is a measurement of the maximum voltage which may be present at the receptacles when a surge occurs.The lower the UL listed voltage rating the better.
- Radio Frequency Interface (RFI) and Electromagnetic Interference (EMI) can interfere with your computer, television and other electronic equipment. Surge suppressors with RFI/EMI filtering can filter out various levels of this interference before it reaches your equipment.
Power Distribution Solutions: Quality Products & Customer Satisfaction
- Expansive model selection. In-house manufacturing allows custom in-stock items
- On-time Delivery. Your shipment is delivered when promised
- No Minimums – Big or small, we value your order
- No Drop ship Penalties for orders shipped within the continental
- No Voice Mail Jail – Real People offering Real Solutions
RELATED ARTICLES -