Home Power & Data Distribution Surge Protectors and Suppressors Industrial Surge Suppressors Power Quality Filter
Zero Surge Power Quality Filter With Total Surge Cancellation
Surpasses Standard MOV Technology and Protects Against Worst-Case Surges
![]()
Close Window
Zero Surge Power Quality Filter With Total Surge Cancellation
This requires one or more of the following: javascript enabled, Flash Video Player, and Quicktime or Windows Media Player E307387 |
Whether you need a rack mount, a 2-outlet for home use, or an 8-outlet for IT rooms, you will find the right surge protector for you application. Zero Surge protectors also offer WVR and TSC technology, which makes these protectors stand out from the rest. |
- Can be used between a wall outlet and a UPS for the ultimate in power protection, providing infinitely more protection than a UPS can on its own
- Able to withstand the worse-case surges, so that linked equipment is not damaged
- Preserves ground reference integrity, which prevents surge suppression peripheral damage
- Comes equipped with two basic filter technologies; WVR®(Wide Voltage Range) and TSC® (Total Surge Cancellation) which are not only safer, but more effective and reliable than other surge protectors
- Black powder coat finish protects the enclosure from corrosion or other possible damage
- Ideal for international use; also well-suited to situations in which generators are used, or brownouts and blackouts frequently occur
- Rated UL 1283, which outperforms the UL 1449 that other devices carry
- 10-year manufacturer's warranty

- Made in the USA

| 2 OUTLETS | 8 OUTLETS | 10 OUTLETS | |||||
| Part # | ZS-2R15T | ZS-2R20T | ZS-8R15T | ZS-8R15T-I | ZS-8R20T | ZS-10R-1U-15T-I | ZS-10R-1U-20T-I |
| Price | |||||||
| Voltage ratings: | US 120 Volt, single phase (one hot leg & a neutral leg tied to earth ground at service entrance). Will operate over a voltage range of 85-175 volts with Spectrum WVR technology (MCOV=175Vac). Full load regulation 1%. Check line wiring for hot/neutral reversal prior to connecting this filter. Hot/neutral reversal is a critical safety issue and will prevent this product from functioning effectively. | US 120 Volt, single phase (one hot leg & a neutral leg tied to earth ground at service entrance). Will operate over a voltage range of 85-175 volts with Spectrum WVR technology (MCOV=175Vac). Full load regulation 1%. | |||||
| Operating temperature range: | 32°F to 104°F (0°C to 40°C) | ||||||
| Technology: | Spectrum WVR® (Wide Voltage Range) filter & TSC (Total Surge Cancellation) | ||||||
| Mode: | Mode 1 applications, L-N (ground wire protection) | ||||||
| Safety certifications: | CSA 22.2 No. 8-M1986, UL 1283 5th edition | CSA 22.2 No. 8-M1986, UL 1283 5th edition, UL 1363 | CSA 22.2 No. 8-M1986, UL 1283 5th edition | ||||
| Limiters: | Series surge reactor current limiter; cascaded, auto-tracking dual polarity dynamic surge and noise sensing; bi-modal dynamic filtering. Parameters optimized for switchmode power supply protection | ||||||
| Dynamic filtering onset: | 172V nominal, 2V above peak line voltage (auto-tracking -WVR) | ||||||
| Max. surge voltage let-through**: | 20 volts above peak line voltage @ 6000V, 3000A for ANSI C62.41 Category B3/C1 Combination Wave | ||||||
| Max. applied pulse voltage: | 6000V (1.2 x 50µs – ANSI C62.41 Combination Wave) | ||||||
| Max. applied pulse current: | >100000A applied (unlimited due to internal current limiting) (8 x 20µs) | ||||||
| Joule rating: | Not applicable to this technology. No MOV’s to wear out. | ||||||
| Endurance rating: | 1000 worst case pulses: ANSI C62.41, Category B3/C1 pulses (6000V, 3000A); >10,000 pulses at 4,000V; >100,000 pulses at 2000V | ||||||
| Filter slew rate: | 5,000V/µs disturbance reduced to 35V/µs within AC power wave envelope; 5V/µs outside the power wave envelope | 5,000V/µs disturbance reduced to 35V/µs within AC power wave envelope; 10V/µs outside the power | 5,000V/µs disturbance reduced to 35V/µs within AC power wave envelope; 5V/µs outside the power wave envelope | ||||
| EMI-RFI filter response: | Bi-directional, wave tracking: With 50 Ω Rgen., load: 7 kHz @ 3 dB; 25 dB@100 kHz; 38dB@300kHz | ||||||
| Dimensions: | 4"W x 8"H x 3"D | 4"W x 9"H x 4"D | 1.75"W x 19"H x 8.5"D | ||||
| Weight: | 5.5 lbs | 6 lbs | 6.5 lbs | 9.25 lbs | |||
| ** Note: Surge voltage let-through is the peak voltage that exceeds the powerline peak voltage. | |||||||
| PART # | DESCRIPTION | AMPS | RECEPTACLES | DIMENSIONS | WEIGHT | PRICE |
| 2 Outlets | ||||||
| ZS-2R15T | Zero Surge, TSC Technology | 15 | 2 | 3"W x 8.5"H x 3"D | 5.5 lbs | |
| ZS-2R20T | Zero Surge, TSC Technology - **Requires 20 AMP wiring and receptacles | 20 | 2 | 3"W x 8.5"H x 4"D | 6 lbs | |
| 8 Outlets | ||||||
| ZS-8R15T | Zero Surge, TSC Technology, Non-isolated | 15 | 8 | 4"W x 9"H x 4"D | 6 lbs | |
| ZS-8R15T-I | Zero Surge, TSC Technology, Isolated | 15 | 8 | 4"W x 9"H x 4"D | 6 lbs | |
| ZS-8R20T | Zero Surge, TSC Technology, Non-isolated - **Requires 20 AMP wiring and receptacles | 20 | 8 | 4"W x 9"H x 4"D | 6.5 lbs | |
| 10 Outlets | ||||||
| ZS-10R-1U-15T-I | Zero Surge, TSC Technology | 15 | 10 | 1.75"W x 19"H x 8.5"D | 9.25 lbs | |
| ZS-10R-1U-20T-I | Zero Surge, TSC Technology - **Requires 20 AMP wiring and receptacles | 20 | 10 | 1.75"W x 19"H x 8.5"D | 9.25 lbs | |
MANUALS & USER GUIDES -
- Zero Surge Power filter 2 R Series Data Sheet (PDF)

- Zero Surge Power filter 8 R Series Data Sheet (PDF)

- Zero Surge Power filter 10 R Series Data Sheet (PDF)

- 10-year manufacturer's warranty
RELATED ARTICLES
- What is a UPS?
- What is a Surge Suppressor?
- Surge Protector Roundup: 7 Cleverly Modern Surge Protectors and where to Use Them
- Energy Conservation Made Easy
- Spend Money to Save Money: Smart Investments That Will Help You Survive the Recession
- Home Safety Checklist