Home Raceway, Duct, Conduit Cable Raceways Cable Raceway Systems OFR Fittings
Wiremold® Over Floor Raceway Hardware
Device Plates, Transitions and Turns for Wiremold OFR Series Raceway
![]()
Close Window
Wiremold® Over Floor Raceway Hardware
This requires one or more of the following: javascript enabled, Flash Video Player, and Quicktime or Windows Media Player WLM-OFR89-2400 Application
|
No high performance power and data distribution raceway is complete without fittings and connectivity accessories. This OFR series raceway hardware from Wiremold® contains everything you need to build a functional and accessible power and data distribution system for your commercial facility. |
- Ideal for all the services you need throughout your facility, including power, data, and video
- Fittings are available for Ortronics® Track Jack, Pass & Seymour, Extron, and more
- Black powder coat finish resists corrosion and moisture and stands up to years of traffic
- cETLus listed for safe electrical operation anywhere in North America
- Proudly made in the USA

| Part # | Description | Dimensions | Pack Quantity | Weight | Price |
| WML-OFR10A | Entrance End Fitting | Click here for dimension | 1 | 3 lbs (1.36 kg) | |
| WML-OFR48-2 | 2-Gang Box | Click here for dimension | 1 | 4 lbs (1.81 kg) | |
| WML-OFR48-4 | 2-Gang Box | Click here for dimension | 1 | 5 lbs (2.68 kg) | |
| WML-OFR48-4GX | Crossover Kit | Click here for dimension | 1 | 4 lbs (1.81 kg) | |
| WML-OFRWC | Wire Clips | Click here for dimension | 1 | 1 lb (.45 kg) | |
| WML-OFR89-2400 | 2400 Raceway Transition | Click here for dimension | 1 | 4 lbs (1.81 kg) | |
| WML-OFR-89-4000 | 4000 Raceway Transition | Click here for dimension | 1 | 4 lbs (1.81 kg) | |
| WML-OFR89-DS4000 | DS4000 Raceway Transition | Click here for dimension | 1 | 4 lbs (1.81 kg) | |
| WML-OFR89-VIS | Large Vista Transition | Click here for dimension | 1 | 4 lbs (1.81 kg) | |
| WML-OFR11 | Flat Elbow | Click here for dimension | 1 | 5 lbs (2.68 kg) | |
| WML-OFR1 | Coupling | Click here for dimension | 2 | 1 lb (.45 kg) | |
| WML-OFR47-B | Blank Device Plate | Click here for dimension | 1 | 2 lbs (0.91 kg) | |
| WML-OFR47-D | Duplex Device Plate | Click here for dimension | 5 | 2 lbs (0.91 kg) | |
| WML-OFR47-R | Decorator Device Plate |
Click here for dimension | 1 | 2 lbs (0.91 kg) | |
| WML-OFR47-U | Extron MAAP Device Plate | Click here for dimension | 1 | 2 lbs (0.91 kg) | |
| WML-OFR47-V | Extron® AAP Device Plate | Click here for dimension | 1 | 2 lbs (0.91 kg) | |
| WML-OFR47-2A | Communications Device Plate | Click here for dimension | 5 | 2 lbs (0.91 kg) | |
| WML-OFR47-U2A | Extron MAAP-2A Combo Device Plate | Click here for dimension | 1 | 2 lbs (0.91 kg) | |
| WML-OFR9 | Grounding Clip | Click here for dimension | 1 | 1 lb (.45 kg) |
| PART # | DESCRIPTION | QUANTITY / PACK | WEIGHT | PRICE |
| Fittings | ||||
| WML-OFR10A | Entrance End Fitting - used to feed the raceway into furniture or out of a wall. Has (2) concentric knockouts on the end (1-1/2" and 1-1/4"). Includes a 4-position divider that can be moved to feed any of the raceway's 4 channels | 1 | 3 lbs (1.36 kg) | |
| WML-OFR48-2 | 2-Gang Box - Has 2 slots for OFR device plates, 1 per side. Removable divider allows feeding from any of the raceway's 4 channels. Contains ample interior space for cable storage. | 1 | 4 lbs (1.81 kg) | |
| WML-OFR48-4 | 2-Gang Box - Has 4 slots for OFR device plates, 2 per side. Removable divider allows feeding from any of the raceway's 4 channels. Contains ample interior space for cable storage. | 1 | 5 lbs (2.68 kg) | |
| WML-OFR48-4GX | Crossover Kit - provides access to services on both sides of OFR48-4 4-Gang Device Box | 1 | 4 lbs (1.81 kg) | |
| WML-OFRWC | Wire Clips - Holds cables in place within the raceway | 1 | 1 lb (.45 kg) | |
| WML-OFR89-2400 | 2400 Raceway Transition - used to connect vertical runs of the STEEL Wiremold 2400 raceway to horizontal runs of OFR raceway | 1 | 4 lbs (1.81 kg) | |
| WML-OFR-89-4000 | 4000 Raceway Transition - used to connect vertical runs of the Wiremold 4000 raceway to horizontal runs of OFR raceway | 1 | 4 lbs (1.81 kg) | |
| WML-OFR89-DS4000 | DS4000 Raceway Transition - used to connect vertical runs of the Wiremold DS4000 raceway to horizontal runs of OFR raceway | 1 | 4 lbs (1.81 kg) | |
| WML-OFR89-VIS | Large Vista Transition - used to feed OFR raceway to Wiremold Vista Point5 Architectural Columns | 1 | 4 lbs (1.81 kg) | |
| WML-OFR11 | Flat Elbow - for making 90° turns using two sections of OFR raceway | 1 | 5 lbs (2.68 kg) | |
| WML-OFR1 | Coupling - securely joins two sections of OFR raceway | 2 | 1 lb (.45 kg) | |
| Device Plates | ||||
| WML-OFR47-B | Blank Device Plate - covers unused slots in device boxes | 1 | 2 lbs (0.91 kg) | |
| WML-OFR47-D | Duplex Device Plate - attach to device boxes to install standard US receptacles | 5 | 2 lbs (0.91 kg) | |
| WML-OFR47-R | Decorator Device Plate - Covers rectangular decorator style devices in OFR48-2 and OFR48-4 Device Boxes. |
1 | 2 lbs (0.91 kg) | |
| WML-OFR47-U | Extron MAAP Device Plate - accepts up to 4 Extron® Electronics MAAP jacks | 1 | 2 lbs (0.91 kg) | |
| WML-OFR47-V | Extron® AAP Device Plate - Accepts two Extron Electronics AAP single space modules | 1 | 2 lbs (0.91 kg) | |
| WML-OFR47-2A | Communications Device Plate – Accepts up to four (4) ports of communications devices, including adapters for Ortronics® TracJack, Series II, Pass & Seymour® Activate inserts and Wiremold Open System communication modules. | 5 | 2 lbs (0.91 kg) | |
| WML-OFR47-U2A | Extron MAAP-2A Combo Device Plate - accepts up to 2 Extron® MAAP and 2 inserts from Ortronics® TracJack, Ortronics® Series II, Wiremold Open System, and Pass & Seymour® Activate | 1 | 2 lbs (0.91 kg) | |
| Grounding | ||||
| WML-OFR9 | Grounding Clip - connects OFR raceway to grounding conductor. Includes No. 10 ground screws | 1 | 1 lb (.45 kg) | |
MANUALS & USER GUIDES -
- OFR Overfloor Raceway Installation Instructions (PDF)

- OFR Overfloor Raceway Device Box Installation Instructions (PDF)

- OFR Overfloor Raceway Transition Fittings Installation Instructions (PDF)

RELATED ARTICLES -
- How to Make Your Facility ADA Compliant
- Warehouse Safety Checklist: How to Reduce Warehouse Liability
- The History of Wiremold
- UL Listing




Ortronics Clarity® TracJack™ Category 5e and 6 Connectors
Ortronics Series II Connector Modules
Facebook Comments