Home Power & Data Distribution Surge Protectors and Suppressors Industrial Surge Suppressors Omni VS Uninterruptible Power Supplies
Tripp Lite Omni VS Series UPS Systems
The Solution to Frequent Brownout Power Problems
![]()
Close Window
Tripp Lite Omni VS Series UPS Systems
This requires one or more of the following: javascript enabled, Flash Video Player, and Quicktime or Windows Media Player |
The Omni VS series UPS is perfect for entry-level PCs, networked workstations, point-of-sale equipment, small business phone systems, audio/video equipment and home theater systems. |
If you find that your area is frequently plagued by brownouts, or a reduction in power, this series is optimal for preventing work interruptions due to power problems.
- Built-in audible alarm alerts you when the power is running very low during an outage so that you can save what you are working on
- Each unit comes with a USB and telephone cable for easy setup
- Attractive black tower
- Built-in RJ45 TEL/Ethernet suppression jacks protect modems, fax machines, cordless phones or other peripherals with a standard single-line TEL/DSL or data line connection
- 800VA to 1500VA power handling ability supports a variety of sensitive electronic equipment
- Supports battery replacement via built-in access panel
- $200,000 Ultimate Lifetime Insurance from Tripp Lite (USA and Canada only)
- 2-year manufacturer's warranty
OMNIVS800 Omni VS UPS System
- Maintains 120V nominal output over an input range of 83 to 132V
- Input: NEMA 5-15P (120V 15A)
- Output: 7 NEMA 5-15R (120V)
- Supports entry level PCs for up to 60 minutes during blackouts to enable shutdown without data loss
- Regulates brownouts as low as 89V back to usable levels without using battery power
- (6) UPS battery supported/surge protected outlets, plus (1) additional surge suppression-only outlet
- Audible alarm
- (4) front panel LEDs
- Line power status
- Battery power status
- Battery low/replace status
- Voltage regulation operation
- 3.5 minutes full load runtime (800VA)
- 11.5 minutes half load runtime (400VA)
- Includes USB and telephone cable, user manual, and warranty information
OMNIVS1000 Omni VS UPS System
- Maintains 120V nominal output over an input range of 83 to 132V
- Input: NEMA 5-15P (120V 15A)
- Output: 8 NEMA 5-15R (120V)
- Supports entry level PCs for up to 60 minutes during blackouts to enable shutdown without data loss
- Regulates brownouts as low as 83V back to usable levels without using battery power
- (6) UPS battery supported outlets, plus (2) additional surge suppression-only outlets
- Audible alarm
- (4) front panel LEDs
- Line power status
- Battery power status
- Battery low/replace status
- Overload
- 3.5 minutes full load runtime (1000VA/500W), 14 minutes half load runtime (500VA/250W)
- Short circuit protection in AC and battery mode
- Includes USB and telephone cable, user manual, and warranty information
OMNIVS1500 Omni VS UPS System
- Maintains 120V nominal output over an input range of 75V to 147V
- Input: NEMA 5-15P (120V 15A)
- Output: 8 NEMA 5-15R (120V)
- Supports entry level PCs for up to 75 minutes during blackouts to enable shutdown without data loss
- Regulates brownouts as low as 75V and overvoltages to 147V back to usable 120V nominal levels without using battery power
- (6) UPS battery supported outlets, plus (2) additional surge suppression-only outlets
- USB port and cable enables UPS monitoring and unattended shutdown in the case of extended power failure
- Built-in audible alarm
- (5) front panel LEDs
- Status of line power
- Battery power
- Battery low/replace
- Voltage regulation
- Overload
- 4 minutes full load runtime (1500VA), 8.5 minutes half load runtime (750VA)
- Includes USB and telephone cable, user manual, and warranty information
OMNIVS1500XL Omni VS UPS System
- Maintains 120V nominal output over an input range of 75V to 147V
- Input: NEMA 5-15P (120V 15A)
- Output: 8 NEMA 5-15R (120V)
- Supports entry level PCs for up to 75 minutes during blackouts to enable shutdown without data loss
- Regulates brownouts as low as 75V and overvoltages to 147V back to usable 120V nominal levels without using battery power
- (6) UPS battery supported outlets, plus (2) additional surge suppression-only outlets
- Built-in audible alarm
- (5) front panel LEDs
- Status of line power
- Battery power
- Battery low/replace
- Voltage regulation
- Overload
- 4.5 minutes full load runtime (1500VA), 13 minutes half load runtime (750VA)
- Runtime is expandable with the addition of external battery packs
- Includes USB and telephone cable, user manual, and warranty information
| Estimated Runtime - Loads in Watts | |||||||||||||
| UPS | 20W | 40W | 60W | 80W | 100W | 200W | 300W | 400W | 500W | 600W | 700W | 800W | 900W |
| TL-OMNIVS800 | 194 | 94 | 59 | 42 | 32 | 13 | 7.1 | 4.5 | - | - | - | - | - |
| TL-OMNIVS1000 | 270 | 133 | 84 | 60 | 46 | 19 | 11 | 6.8 | 3.5 | - | - | - | - |
| TL-OMNIVS1500 | 294 | 177 | 124 | 93 | 74 | 34 | 20 | 14 | 8.3 | 7.3 | 6.4 | 5.2 | 4.3 |
| TL-OMNIVS1500XL | 323 | 188 | 129 | 96 | 76 | 34 | 21 | 14 | 11 | 8.1 | 6.4 | 5.2 | 4.3 |
All runtime values are in minutes |
|||||||||||||
| TL-OMNIVS800 | TL-OMNIVS1000 | TL-OMNIVS1500 | TL-OMNIVS1500XL | |
| Price | ||||
| SYSTEM OVERVIEW | ||||
| Voltage compatibility: | 120VAC | 120VAC | 120VAC | 120VAC |
| Frequency compatibility: | 60 Hz | 60 Hz | 60 Hz | 60 Hz |
| OUTPUT | ||||
| Output VA: | 800 | 1000 | 1500 | 1500 |
| Output watts: | 475 | 500 | 940 | 940 |
| Output nominal voltage: | 120VAC | 120VAC | 120VAC | 120VAC |
| Line Mode Output voltage regulation: | - | - | Sine wave line voltage 120V (-18%/8%) | Sine wave line voltage 120V (-18%/8%) |
| Battery Mode Output voltage regulation: | PWM sine wave output 115V ±5% | PWM sine wave output 115V ±5% | PWM sine wave output 120V ±5% | PWM sine wave output 120V ±5% |
| Line Mode Output frequency regulation: | Passes line frequency of 60Hz. ±10% | Passes line frequency of 60Hz. ±10% | Passes line frequency of 60Hz. ±10% | Passes line frequency of 60Hz. ±10% |
| Battery Mode Output frequency regulation: | Inverter output regulated to 60Hz ±0.5Hz | Inverter output regulated to 60Hz ±0.5Hz | Inverter output regulated to 60Hz ±0.5Hz | Inverter output regulated to 60Hz ±0.5Hz |
| Outlet quantity/type: | 7 NEMA 5-15R | 8 NEMA 5-15R | 8 NEMA 5-15R | 8 NEMA 5-15R |
| INPUT | ||||
| Maximum input amps: | 12A | 12A/1440W | 12A | 12A |
| Input connection type: | NEMA 5-15P right-angle plug | NEMA 5-15P right-angle plug | NEMA 5-15P | NEMA 5-15P |
| Input cord length: | 6' 14 gauge | 6' 14 gauge | 6' 14 gauge | 6' 14 gauge |
| Recommended electrical service: | 15A 120V | 15A 120V | 15A 120V | 15A 120V |
| BATTERY | ||||
| Full load runtime: | 3.5 minutes (800VA) | 3.5 minutes (1000VA) | 4 minutes (1500VA) | 4.5 minutes (1500VA) |
| Half load runtime: | 11.5 minutes (400VA) | 14 minutes (500VA) | 8.5 minutes (750VA) | 13 minutes (750VA) |
| DC system voltage: | 12VDC | 12VDC | 24VDC | 24VDC |
| Typical battery lifespan: | 3 to 6 years | 3 to 6 years | 3 to 6 years | 3 to 6 years |
| Battery recharge rate: | 2 to 4 hours to 90% | 2 to 4 hours to 90% | 2 to 4 hours to 90% | 2 to 4 hours to 90% |
| Replacement battery cartridge: | RBC51 | RBC52 (quantity 2) | RBC51 (quantity 2) | RBC51 (quantity 2) |
| VOLTAGE REGULATION | ||||
| Voltage regulation description: | Line interactive voltage regulation corrects brownouts as low as 83V back to usable values | Line interactive voltage regulation corrects brownouts as low as 83V back to usable values | AVR circuits maintain clean, regulated computer-grade 120V nominal output, without using battery power, during brownouts to 75V and overvoltages to 147V | AVR circuits maintain clean, regulated computer-grade 120V nominal output, without using battery power, during brownouts to 75V and overvoltages to 147V |
| Over voltage correction: | - | - | Input voltages between 128 and 147VAC are reduced by 12% | Input voltages between 128 and 147VAC are reduced by 12% |
| Direct pass through: | Voltages of 106V+ are passed through to connected equipment unchanged | Voltages of 106V+ are passed through to connected equipment unchanged | Input voltages between 108 and 127VAC are passed on to connected equipment unchanged | Input voltages between 108 and 127VAC are passed on to connected equipment unchanged |
| Brownout correction: | Input voltages between 83 and 105 are boosted by 14% | Input voltages between 83 and 105 are boosted by 14% | Input voltages between 93 and 107VAC are boosted by 14% | Input voltages between 93 and 107VAC are boosted by 14% |
| Severe brownout correction: | - | - | Input voltages between 75 and 92VAC are boosted by 30% | Input voltages between 75 and 92VAC are boosted by 30% |
| LEDS ALARMS & SWITCHES | ||||
| Front panel LEDs: | 4 status indicator LEDs: - Line power - Battery power - Battery low/replace - Voltage regulation operation |
4 status indicator LEDs: - Line power - Battery power - Battery low/replace - Overload |
5 status indicator LEDs: - Battery charge level - AC line voltage levels - Automatic voltage regulation status - UPS load level - Replace battery warning |
5 status indicator LEDs: - Battery charge level - AC line voltage levels - Automatic voltage regulation status - UPS load level - Replace battery warning |
| Audible alarms - assuming full load: | Indicates loss of utility power. Silence by pressing front panel alarm cancel button, alarm will re-sound when 2 minutes runtime remains. | Indicates loss of utility power. Silence by pressing front panel alarm cancel button, alarm will re-sound when 2 minutes runtime remains. | Indicates loss of utility power. Silence by pressing front panel alarm cancel button, alarm will re-sound when 2 minutes runtime remains. | Indicates loss of utility power. Silence by pressing front panel alarm cancel button, alarm will re-sound when 2 minutes runtime remains. |
| Front panel switches: | - (1) main on/off power - (1) dual function alarm cancel/self test button |
- (1) main on/off power - (1) dual function alarm cancel/self test button |
- (1) main on/off power - (1) dual function alarm cancel/self test button |
- (1) main on/off power - (1) dual function alarm cancel/self test button |
| SURGE/NOISE SUPPRESSION | ||||
| AC surge suppression: | 480 joules | 480 joules | 510 joules | 510 joules |
| AC suppression response time: | Instantaneous | Instantaneous | Instantaneous | Instantaneous |
| Dataline suppression: | Tel/DSL/Ethernet | Tel/DSL/Ethernet | Tel/DSL/Ethernet | Tel/DSL/Ethernet |
| EMI/RFI AC noise suppression: | Yes | Yes | Yes | Yes |
| PHYSICAL | ||||
| Shipping weight: | 23.2 lbs. (10.5 kg) | 23.2 lbs. (10.5 kg) | 30 lbs. (13.5 kg) | 30 lbs. (13.5 kg) |
| Shipping dimensions: | 14"H x 8.5"W x 10.5"D (35.6 x 21.6 x 26.7 cm) |
14"H x 8.5"W x 10.5"D (35.6 x 21.6 x 26.7 cm) |
15.5"H x 11"W x 11.25"D (39.4 x 28 x 28.6 cm) |
15.5"H x 11"W x 11.25"D (39.4 x 28 x 28.6 cm) |
| Unit weight: | 21.2 lbs. (9.6 kg) | 21.2 lbs. (9.6 kg) | 28 lbs. (12.6 kg) | 28 lbs. (12.6 kg) |
| Unit dimensions: | 10.75"H x 5.25"W x 7.25"D (27.3 x 13.4 x 18.4 cm) |
10.75"H x 5.25"W x 7.25"D (27.3 x 13.4 x 18.4 cm) |
11.75"H x 7.25"W x 7.5"D (29.8 x 18.4 x 19.1 cm) |
11.75"H x 7.25"W x 7.5"D (29.8 x 18.4 x 19.1 cm) |
| Material of construction: | PVC | PVC | Polycarbonate | Polycarbonate |
| Form factors supported: | Tower | Tower | Tower | Tower |
| Cooling method: | Convection | Convection | Convection | Fan |
| Battery Access: | Battery access door allows user replacement of UPS batteries. | Battery access door allows user replacement of UPS batteries. | Battery access door allows user replacement of UPS batteries, hot swappable battery replacement supported | Battery access door allows user replacement of UPS batteries, hot swappable battery replacement supported |
| ENVIRONMENTAL | ||||
| Operating Temperature: | 32°F to 104°F (0°C to 40°C) | 32°F to 104°F (0°C to 40°C) | 32°F to 104°F (0°C to 40°C) | 32°F to 104°F (0°C to 40°C) |
| Storage Temperature: | 5°F to 122°F (-15°C to 50°C) | 5°F to 122°F (-15°C to 50°C) | 5°F to 122°F (-15°C to 50°C) | 5°F to 122°F (-15°C to 50°C) |
| Relative Humidity: | 0 to 95%, non-condensing | 0 to 95%, non-condensing | 0 to 95%, non-condensing | 0 to 95%, non-condensing |
| Line mode BTU/hr. max. | - | 43.6 | - | - |
| Battery mode BTU/hr. max. | - | 147.8 | - | - |
| COMMUNICATIONS | ||||
| Network monitoring port: | USB | USB | USB | USB |
| Cabling included: | USB and telephone | USB and telephone | USB and telephone | USB and telephone |
| Software: | PowerAlert download | PowerAlert download | PowerAlert download | PowerAlert download |
| WatchDog compatibilty: | Yes, restore operation to locked equipment through soft reboot of application/OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications | Yes, restore operation to locked equipment through soft reboot of application/OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications | Yes, restore operation to locked equipment through soft reboot of application/OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications | Yes, restore operation to locked equipment through soft reboot of application/OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications |
| LINE/BATTERY TRANSFER | ||||
| Transfer time from line power to battery mode: | 2 to 4 milliseconds | 2 to 4 milliseconds | 2 to 4 milliseconds | 2 to 4 milliseconds |
| Low voltage transfer to battery power: | Switches to battery power as line voltage decreases to 83V or less. Resets to line power mode as line voltage increases to 87V or more | Switches to battery power as line voltage decreases to 83V or less. Resets to line power mode as line voltage increases to 87V or more | Switches to battery power as line voltage decreases to 75V or less. Resets back to line power mode as line voltage increases to 79V or more | Switches to battery power as line voltage decreases to 75V or less. Resets back to line power mode as line voltage increases to 79V or more |
| High voltage transfer to battery power: | Switches to battery power as line voltage increases to 147V or higher. Resets to line power mode as line voltage decreases to 143V or less. | Switches to battery power as line voltage increases to 147V or higher. Resets to line power mode as line voltage decreases to 143V or less. | Switches to battery power as line voltage increases to 147Vs or higher. Resets back to line power mode as line voltage decreases to 143V or less. | Switches to battery power as line voltage increases to 147V or higher. Resets back to line power mode as line voltage decreases to 143V or less. |
| SPECIAL FEATURES | ||||
| Cold Start: | Yes | Yes | Yes | Yes |
| Appearance: | Black | Black | Black | Black |
| CERTIFICATIONS | ||||
| Certifications: | Tested to UL1778 (USA), CSA C22.2 No. 107.3 (Canada), Class B (emissions), NOM (Mexico), FCC Part 68 Industry Canada (telecommunications), RoHS Compliant | Tested to UL1778 (USA), cUL (Canada), Class B (emissions), NOM (Mexico), FCC Part 68 Industry Canada (telecommunications) | Tested to UL1778 (USA), CSA (Canada), NOM (Mexico), FCC Class B (Emissions) | Tested to UL1778 (USA), CSA (Canada), NOM (Mexico), FCC Class B (Emissions) |
| WARRANTY | ||||
| Manufacturer's product warranty: | 2-year | 2-year | 2-year | 2-year |
| Connected equipment insurance (USA and Canada Only): | $200,000 | $200,000 | $200,000 | $200,000 |
| Optional manufacturer's coverage: | 3 to 5 year warranties, next day and on-site warranty coverage available | 3 to 5 year warranties, next day and on-site warranty coverage available | 3 to 5 year warranties, next day and on-site warranty coverage available | 3 to 5 year warranties, next day and on-site warranty coverage available |
| PART # | DESCRIPTION | VOLTS | FULL LOAD RUNTIME | DIMENSIONS | WEIGHT | PRICE |
| TL-OMNIVS800 | Omni VS UPS System | 800 | 3.5 min. | 14"H x 8.5"W x 10.5"D | 23.2 lbs. | |
| TL-OMNIVS1000 | Omni VS UPS System | 1000 | 3.5 min. | 14"H x 8.5"W x 10.5"D | 23.2 lbs. | |
| TL-OMNIVS1500 | Omni VS UPS System | 1500 | 4 min. | 15.5"H x 11"W x 11.25"D | 30 lbs. | |
| TL-OMNIVS1500XL | Omni VS XL UPS System | 1500 | 4.5 min. | 15.5"H x 11"W x 11.25"D | 30 lbs. |