Tripp Lite Full Isolation Medical Grade Series UPS Systems
Reliable Power Source for Hospitals and Health Care Facilities
![]()
Close Window
Tripp Lite Medical Grade UPS Systems
This requires one or more of the following: javascript enabled, Flash Video Player, and Quicktime or Windows Media Player |
These medical grade UPS systems can eliminate disruptions and damage to sensitive equipment and make your power sources more reliable. |
OmniSmart Full Isolation UPS Systems are ideal for medical applications, and allow you to install a single battery backup solution to provide all the benefits of a dedicated AC input line without the expense and inconvenience of running special circuits and upgrading site wiring.
- Built in communication ports
- Includes (4) high quality protected hospital-grade outlets and a 6' cord
- Extended runtime capability on select models
- Full-isolation UPS system is a key feature when dealing with sensitive equipment and operations
- Consistent battery power will keep systems up and running through short blackouts, and give you time to safely shut down during longer ones
- Each AC outlet prevents damage from lightning and surges
- Low 100µA leakage of current from connected healthcare equipment
- Each of these models feature a hospital-grade plug and receptacles designed for use both inside and outside of patient-care areas
- Resistant to electrostatic discharge
- Equipped with battery replacement door and back panel grounding lug
- Provides surge protection, line isolation and EMI/RFI noise filtering
- Complete remote monitoring cabling included
- PowerAlert UPS management software available via free download
- 2-year manufacturer's warranty
Applications:
- Patient point-of-care solutions
- Tele-medicine
- Nurse's stations
- Wireless communications systems
- Electronic prescribing applications
- Medical imaging
- Mission critical equipment
*Not recommended for life support applications
OMNISMART350HG Omni Smart UPS System
- Supports loads up to 330VA/225W and maintains sine-wave 120V nominal output over an input range of 83 to 132V
- Input: Hospital-grade NEMA 5-15P (120V 15A)
- Output: 4 Hospital-grade NEMA 5-15R (120V)
- 2-line phone suppression for TEL/DSL line protection
- 46 minutes half load runtime (with 165VA load)
- 18 minutes full load runtime (with 330VA load)
- (1) DB9 serial port for network interface
- (4) diagnostic LEDs
- AC present
- On battery
- Voltage correction
- Battery low/replace
- Serial cable for remote monitoring, warranty information, and instruction manual included
SMART700HG SmartPro UPS System
- Supports loads up to 700VA/450 watts and maintains 120V nominal output over an input range of 82 to 142V
- Input: NEMA 5-15P (120V 15A)
- Output: 4 NEMA 5-15R (120V)
- Line-interactive voltage regulation corrects brownouts and over voltages from 81 to 143 volts back to usable 120V output levels, without using battery power
- 42 minutes half load runtime (with 350VA load)
- 18 minutes full load runtime (with 700VA load)
- 5 diagnostic LEDs
- AC present
- On battery
- Voltage correction
- Overload
- Battery low/replace
- (1) USB and (1) DB9 monitoring cable, warranty information, and instruction manual included
SMART1200XLHG SmartPro XL Medical Grade UPS System
- Supports loads up to 1000VA/750W and maintains 120V nominal output over an input range of 82 to 142V
- Input: Hospital-grade NEMA 5-15P (120V 15A)
- Output: 4 Hospital-grade NEMA 5-15R (120V)
- Expandable runtime is available with the addition of one or more external battery packs (BP36V15-2U limit 1 or BP36V42-3U multi-pack compatible)
- 28 min. half-load runtime (500VA/375W)
- 10 min. full load runtime (1000VA/750W)
- Equipped with USB and DB9 communication ports
- 5 diagnostic LEDs
- AC present
- On battery
- Voltage correction
- Overload
- Battery low/replace
- PowerAlert Software and cabling, warranty information, and instruction manual included
| Estimated Runtime - Loads in Watts | |||||||||||||||||
| UPS | 20W | 40W | 60W | 80W | 100W | 120W | 140W | 160W | 180W | 200W | 260W | 300W | 340W | 400W | 500W | 600W | 700W |
| TL-OMNISMART350HG | 178 | 109 | 76 | 58 | 46 | 42 | 32 | 27 | 24 | 21 | - | - | - | - | - | - | - |
| TL-SMART700HG | 347 | 218 | 155 | 119 | 95 | - | 66 | - | - | 44 | 31 | 26 | 22 | 19 | - | - | - |
| TL-SMART1200XLHG | 505 | 305 | 214 | 162 | 129 | - | - | - | - | 60 | - | 37 | - | 25 | 19 | 15 | 12 |
All runtime values are in minutes |
|||||||||||||||||
| TL-OMNISMART350HG | TL-SMART700HG | TL-SMART1200XLHG | |
| Price | |||
| SYSTEM OVERVIEW | |||
| Voltage compatibility: | 120VAC | 120VAC | 120VAC |
| Frequency compatibility: | 60 Hz | 60 Hz | 60 Hz |
| OUTPUT | |||
| Output VA: | 330 | 700 | 1000 |
| Output watts: | 225 | 450 | 750 |
| Output nominal voltage: | 120VAC | 120VAC | 120VAC |
| Line Mode Output voltage regulation: | Sine wave line voltage 120V (-18%/8%) | Sine wave line voltage 120V (-18%/8%) | Sine wave line voltage 120V (-18%/8%) |
| Battery Mode Output voltage regulation: | PWM sine wave output 120V ±5% | - | PWM sine wave output 115V ±5% |
| Line Mode Output frequency regulation: | Passes line frequency of 60Hz. ±10% | Passes line frequency of 60Hz ±10% | Passes line frequency of 60Hz ±10% |
| Battery Mode Output frequency regulation: | Inverter output regulated to 60Hz ±0.5Hz | - | Inverter output regulated to 60Hz ±0.5Hz |
| Outlet quantity/type: | 4 NEMA 5-15R-HG Hospital-Grade | 4 NEMA 5-15R-HG Hospital-Grade | 4 NEMA 5-15R-HG Hospital-Grade |
| INPUT | |||
| Overload Protection: | Resettable circuit breaker | Resettable circuit breaker | - |
| Maximum input amps: | 2.3A/250W | 5.5A/550W | 9.2A/860W |
| Input connection type: | NEMA 5-15P-HG Hospital-Grade | NEMA 5-15P-HG Hospital-Grade | NEMA 5-15P-HG Hospital-Grade |
| Input cord length: | 6' 14 gauge | 6' 14 gauge | 6' 14 gauge |
| Recommended electrical service: | 15A 120V | 15A 120V | 15A 120V |
| BATTERY | |||
| Full load runtime: | 18 minutes (330VA) | 18 minutes (700VA) | 10 min. (1000VA) |
| Half load runtime: | 46 minutes (165VA) | 42 minutes (350VA) | 28 min. (500VA) |
| DC system voltage: | 12VDC | 36VDC | 36VDC |
| Typical battery lifespan: | 3-6 years, depending on usage | 3-6 years, depending on usage | 3-6 years, depending on usage |
| Battery recharge rate: | 2-4 hours to 90% | 2-4 hours to 90% | 2-4 hours to 90% |
| Replacement battery cartridge: | RBC52 (quantity 2) | - | - |
| VOLTAGE REGULATION | |||
| Voltage regulation description: | 1 boost level of brownout correction to maintain usable, computer grade output. | 2 boost levels of brownout correction and a single level of over voltage adjustment to maintain usable, computer grade output without consuming battery power over an input voltage range of 81 to 143VAC | 2 boost levels of brownout correction and a single level of over voltage adjustment to maintain usable, computer grade output without consuming battery power over an input voltage range of 81 to 143VAC |
| Over voltage correction: | Input voltages between 126 and 143VAC are reduced by 9% | Input voltages between 126 and 143VAC are reduced by 9% | - |
| Direct pass through: | Input voltages between 108 and 147VAC are passed through unchanged | Input voltages between 105 and 125VAC are passed through unchanged | Input voltages between 105 and 125VAC are passed through unchanged |
| Brownout correction: | Input voltages between 83 and 107VAC are boosted by 14% | Input voltages between 96 and 106VAC are boosted by 10% | Input voltages between 96 and 106VAC are boosted by 10% |
| Severe brownout correction: | Input voltages between 81 and 95VAC are boosted by 21% | Input voltages between 81 and 95VAC are boosted by 21% | - |
| LEDS ALARMS & SWITCHES | |||
| Front panel LEDs: | 4 status indicator LEDs: - Line power - Battery power - Voltage regulation and - Battery low/replace status |
5 indicator LEDs: - Battery charge level - AC line voltage levels - Automatic voltage regulation status - UPS load level - Replace battery warning |
5 indicator LEDs: - Battery charge level - AC line voltage levels - Automatic voltage regulation status - UPS load level - Replace battery warning |
| Alarms - assuming full load: | Indicates power failure, silenceable via alarm cancel switch. Once cancelled, alarm will resume when approximately 2 minutes of battery operation remain (assuming full load) | 3 function audible alarm indicates: |
3 function audible alarm indicates: - Power failure conditions (4 beeps/10 sec) - Overload (continuous beeps) - Low battery (continuous tone) |
| Front panel switches: | -
System enable |
-
System enable - Self-test - Cancel Alarm |
-
System enable - Self-test - Cancel Alarm |
| SURGE/NOISE SUPPRESSION | |||
| AC surge suppression: | 480 joules | 480 joules | 480 joules |
| AC suppression response time: | Instantaneous | Instantaneous | Instantaneous |
| Dataline suppression: | (2) Line Tel/DSL | ||
| EMI/RFI AC noise suppression: | Yes | Yes | Yes |
| PHYSICAL | |||
| Shipping weight: | 26.5 lbs. (12 kg) | 48 lbs. (21.8 kg) | 49.2 lbs. (22.4 kg) |
| Unit weight: | 25 lbs. (11.4 kg) | 44.6 lbs. (20.2 kg) | 45.2 lbs. (20.5 kg) |
| Unit Dimensions: | 10.75"H x 5.25"W x 7.25"D (27.3 x 13.3 x 18.4 cm) |
12.75"H x 7.5"W x 9"D (32.4 x 19.1 x 22.9 cm) |
18.25"H x 11.75"W x 13.5"D (46.4 x 29.8 x 34.3 cm) |
| Material of construction: | PVC | PVC | PVC |
| Form factors supported: | Tower | Tower | Tower |
| Cooling method: | Convection | Cooling via rear-exit cooling fan | Cooling via rear-exit fan |
| Battery Access: | Battery access door allows hot swap battery replacement without powering connected equipment off | Battery access door allows hot swap battery replacement without powering connected equipment off | Battery access door allows hot swap battery replacement without powering connected equipment off |
| ENVIRONMENTAL | |||
| Operating Temperature: | 32°F to 104°F (0° to 40°C) | 32°F to 104°F (0° to 40°C) | 32°F to 104°F (0° to 40°C) |
| Storage Temperature: | 5°F to 122°F (-15°C to 50°C) | 5°F to 122°F (-15°C to 50°C) | 5°F to 122°F (-15°C to 50°C) |
| Relative Humidity: | 0 to 95%, non-condensing | 0 to 95%, non-condensing | 0 to 95%, non-condensing |
| COMMUNICATIONS | |||
| Network monitoring port: | DB9 | (1) USB and (1) RS232 | (1) USB and (1) DB9 |
| Cabling included: | (1) DB9 cable | (1) USB to USB, (1) DB9 to DB9 | (1) USB to USB, (1) DB9 to DB9 |
| Software: | PowerAlert download | PowerAlert download | PowerAlert |
| LINE/BATTERY TRANSFER | |||
| Transfer time from line power to battery mode: | 2 to 4 milliseconds | 2 to 4 milliseconds | 2 to 4 milliseconds |
| Low voltage transfer to battery power: | 83V (resets to line power as voltage increases to 87V) | 81V (resets to line power as voltage increases to 85V) | 81V (resets to line power as voltage increases to 85V) |
| High voltage transfer to battery power: | 147V (resets to line power as voltage decreases to 143V) | 143V (resets to line power as voltage decreases to 139V) | 143V (resets to line power as voltage decreases to 139V) |
| SPECIAL FEATURES | |||
| Cold Start: | Inverter can be cold started to enable temporary AC output during a power failure | Inverter can be cold started to enable temporary AC output during a power failure | Inverter can be cold started to enable temporary AC output during a power failure |
| Appearance: | Gray tower | Gray tower | Gray tower |
| CERTIFICATIONS | |||
| Certifications: | Tested to UL1778 (USA, Series AGOM350KSR57HG), UL60601-1 (Medical), cUL (Canada), Class B (emissions), FCC Part 68 Industry of Canada (telecommunications) | Tested to UL1778 (USA, Series AGSM700PSR3HG), UL60601-1 (Medical), cUL (Canada), FCC Class A (emissions) | Tested to UL1778 (USA, Series AGSM1200PSR3HG), UL 60601-1 (Medical), cUL (Canada), FCC Class A (Emissions) |
| WARRANTY | |||
| Manufacturer's product warranty: | 2-year | 2-year | 2-year |
| Optional coverage: | 3-year, 5-year, next day and on-site warranty coverage available | 3-year, 5-year, next day and on-site warranty coverage available in many areas; contact Tripp Lite | 3-year, 5-year, next day and on-site warranty coverage available in many areas; contact Tripp Lite |
| PART # | DESCRIPTION* | VOLTS | FULL LOAD RUNTIME | DIMENSIONS | WEIGHT | PRICE |
| TL-OMNISMART350HG | Omni Smart UPS System |
330 | 18 min. | 10.75"H x 5.25"W x 7.25"D | 26.5 lbs. | |
| TL-SMART700HG | SmartPro UPS System |
700 | 18 min. | 12.75"H x 7.5"W x 9"D | 48 lbs. | |
| TL-SMART1200XLHG | SmartPro XL Medical Grade UPS System |
1000 | 10 min. | 18.25"H x 11.75"W x 13.5"D | 49.2 lbs. |
*Not recommended for life support applications