Home Test Equipment Clamp Meters Triplett Digital Clamp-on Meters
Digital Clamp-On Meters
Affordable Clamp-Ons For Today's Maintenance Needs
![]()
Close Window
Digital Clamp-On Meters
This requires one or more of the following: javascript enabled, Flash Video Player, and Quicktime or Windows Media Player |
These very affordable digital clamp-on meters meet all the necessary requirements for today's maintenance needs |
Model 9200:
|
Model 9310:
|
| 9200 | 9310 | |
|---|---|---|
| Display | 3-3/4 digit, 4000 count | 3-3/4 digit LCD with a maximum reading of 3999 |
| Dimensions | 5.8"(L) x 1.8"(W) x 0.8" (H) | 8.7"(L) x 3.3"(W) x 1.8"(H) |
| Sampling Rate | 3 times per second | |
| Insulation Voltage Endurance | - | |
| Power Supply | One 3 Volt CR2032 Button Type | One standard 9V battery (included) |
| Battery Life | Approximately 200 hours | |
| Low Battery Indication | Replace when "BAT" is displayed. | |
| Environmental | Operating: 32 F ~ 113 F; 80% RH. | |
| Storage: -4 F ~ 140 F; 80% RH. | ||
| Humidity: 0 to 80% for 0 C to 35° C; 0 to70% for 35° C to 45° C | ||
| Altitude: 2000m (6,560 ft) | ||
| Maximum Conductor Size | 38mm dia. (1.5") Can accept one 750 MCM cable or two 350 MCM cables | |
| Included Accessories | Carrying Case, Test Leads, Manual, Battery. | |
| DC Voltage | 4(400mV to 400V) 0.5% rdg + 2 LSD | |
| 1(600V) 0.8% rdg + 3 LSD | ||
| AC Voltage | 1(400mV) 1.5% rdg + 3 LSD | |
| 3(4V to 400V) 1.0% rdg + 2 LSD | ||
| 1(600V) 1.5% rdg + 3 LSD | ||
| DC Current | 1(400A) 1.5% rdg + 5 LSD | |
| 1(1000A) 2.0% rdg + 10 LSD | ||
| AC Current | 2(40A & 200A) 1.8% rdg + 5 LSD | 1(400A) 2.0% rdg + 5 LSD |
| 1(1000A) 2.5% rdg + 10 LSD | ||
| Resistance | 5(400Ω to 4MΩ) 1.0% rdg + 2 LSD 1(40MΩ) 2.0% rdg + 3 LSD |
|
| Frequency | 7 (10Hz to 10MHz) 0.1% rdg + 5 LSD | |
| Continuity | Yes | |
| Diode Check | Yes | |
| Total Ranges / Functions | 2 | 36 |
| Overload protection | 400A AC for 60 Seconds Max. | 600V AC/DC Ω Ranges |
| Agency Approval | IEC 1010-1 (EN61010-1) IEC 1010-2-032 CE |
IEC 1010-1(EN61010-1) CAT III 600 Volts AC/DC CAT II 1000 Volts DC, 750 Volts AC IEC 1010-2-032 CE: EMC, LVD |
| True RMS | N/A | |
| Autoranging | Yes | Yes |
| Data Hold | Yes | Yes |
| Low Battery Indication | Yes | Yes |
| Max. Conductor Size | 1.14" (27mm) | 1.5" (38mm) |
| Battery | 1-3V | 1-9V |
| Dimensions | 5.8"(L) x 1.8"(W) x 0.8" (H) | 8.7"(L) x 3.3"(W) x 1.8"(H) |
| Weight | 3.4 oz | 14 oz |
| Part # | Description | Dimensions | Weight | Price |
| TR-9200 | Mini AC Clamp-On Meter | 8-1/2" x 5-1/4" x 2-1/4" | 3.4 oz | |
| TR-9310 | AC/DC Clamp-On Meter | 8-1/2" x 5-1/4" x 2-1/4" | 14 oz | |
| ACCESSORIES | ||||
| TR-79-760 | 48" Test Leads with Insulated Screw-on Alligator Clips | 48" | 0.3 lb | |
| TR-10-4275 | Universal Carrying Case | 7-1/2"H x 6"W x 1-1/2"D | 0.25 lb | |
Instrument ratings:
The first important rating is the measurement range. For voltage measurement, this is the maximum voltage that can be applied to the test terminals. This doesn't mean, however, that measurements can always be made safely at that voltage. Read more
MANUALS -
- Model 9300 AC Clamp on Meter Manual (PDF)

- Model 9310 AC Clamp on Meter Manual (PDF)

- Model 9320 AC Clamp on Meter Manual (PDF)

RELATED ARTICLES -
- Why Earth Resistance Can Only Be Found By Clamping It
- 10 Easy Ways to Protect Against Electrical Hazards



Facebook Comments