Home Electrical GFCI GFCI Protected Extension Cords
TRC® ShockShield® GFCI Protected Cords
Simple Extension Provides Heavy Duty Electrical Protection
![]()
Close Window
TRC® ShockShield® GFCI Protected Cords
This requires one or more of the following: javascript enabled, Flash Video Player, and Quicktime or Windows Media Player |
Distributing electricity can get tricky around the workplace, TRC® ShockShield® GFCI extension wires make the process easy and extremely safe. More |
Built with GFCI protection and expanding up to 100 feet in length, this is a safety feature for your workplace that can avoid injury to your employees as well as costly equipment damage. Made to last, efficient and affordable, these GFCI protected extension cords are sure to be considered a priority investment for your business or personal use.
- Up to 12 AWG cables for durability
- Typical applications include:
- Construction Sites
- Portable Electric Power Tools
- Saws and Drills
- Multiple Tools Use
- Basements
- Bathrooms
- Laundry Rooms
- Kitchens
- Any place where electricity is used around water
- TRC-14880 dimensions (PDF)

- TRC-14880 Tri Cord Plug dimensions (PDF)

- TRC-26020, TRC-25080, TRC-25090, TRC-26000 dimensions (PDF)

- TRC-26020 Tri Cord Plug dimensions (PDF)

- TRC-44700, TRC 44720 dimensions (PDF)

- NEMA Plug and Receptacle Configurations (PDF)

| Technical Data | Right Angle Cord Sets From $26.23 to $75.56 |
In-Line Cord Sets From $39.08 to $78.36 |
In-Line Cords with Locking Plug From $41.53 to $146.10 |
Protected Tri-Cord From $36.24 to $107.02 |
| Ground Neutral | 4 Ohms typical | 4 Ohms typical | 4 Ohms typical | 4 Ohms typical |
| Trip response time for ground and grounded neutral trip | fault less than 25mS | fault less than 25mS | fault less than 25mS | fault less than 25mS |
| Voltage surge withstand | 3kv ringwave test and 4kv/2kA surge immunity test | 3kv ringwave test and 4kv/2kA surge immunity test | 3kv ringwave test and 4kv/2kA surge immunity test | 3kv ringwave test and 4kv/2kA surge immunity test |
| Radio frequency noise susceptibility | operates within normal limits with 0.5 volts injected on power line 150kHz-230mHz | operates within normal limits with 0.5 volts injected on power line 150kHz-230mHz | operates within normal limits with 0.5 volts injected on power line 150kHz-230mHz | operates within normal limits with 0.5 volts injected on power line 150kHz-230mHz |
| Frequency | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz |
| Endurance | 3,000 operations minimum | 3,000 operations minimum | 3,000 operations minimum | 3,000 operations minimum |
| Overload Current | six times rated current | six times rated current | six times rated current | six times rated current |
| Operating temperature range | -35°C to 66°C | -35°C to 66°C | -35°C to 66°C | -35°C to 66°C |
| Effect of 10 Amp turn DC Shock on ground fault trip | 5% maximum trip level variation |
5% maximum trip level variation |
5% maximum trip level variation |
5% maximum trip level variation |
| Insulation voltage | 1500VRMS - 1Min. | 1500VRMS - 1Min. | 1500VRMS - 1Min. | 1500VRMS - 1Min. |
| Power On indication | mechanical indicator | lighted indicator | mechanical indicator, red stripe on reset | lighted indicator |
| PART # | RECEPTACLE | VOLTAGE | GAUGE | LENGTH | WEIGHT | PRICE |
| TRC® ShockShield® GFCI RIGHT ANGLE Cord Set | ||||||
| TRC-14880-001 | - | 120V/15A | 14/3 AWG | 9" | 0.3 lb | |
| TRC-14880-024 | - | 120V/15A | 14/3 AWG | 6 ft | 0.8 lb | |
| TRC-14880-074 | - | 120V/15A | 14/3 AWG | 25 ft | 2.28 lbs | |
| TRC-14880-122 | - | 120V/15A | 14/3 AWG | 50 ft | 4.23 lbs | |
| TRC-14880-012 | - | 120V/15A | 12/3 AWG | 9" | 0.43 lb | |
| TRC-14880-013 | - | 120V/15A | 12/3 AWG | 6 ft | 1.27 lbs | |
| TRC-14880-018 | - | 120V/15A | 12/3 AWG | 25 ft | 4.26 lbs | |
| TRC-14880-029 | - | 120V/15A | 12/3 AWG | 50 ft | 8.18 lbs | |
| TRC® ShockShield® GFCI Protected Right Angle Tri-Cord Plug | ||||||
| TRC-14880-023 | - | 120V/15A | n/a | 2 ft | 1 lb | |
| TRC-14880-004 | - | 120V/15A | n/a | 6 ft | 1.6 lbs | |
| TRC-14880-118 | - | 120V/15A | n/a | 25 ft | 4.26 lbs | |
| TRC-14880-119 | - | 120V/15A | n/a | 50 ft | 8.4 lbs | |
| TRC-14880-120 | - | 120V/15A | n/a | 99 ft | 12 lbs | |
| TRC-14880-226 | Lighted | 120V/15A | n/a | 2 ft | 1 lb | |
| TRC® ShockShield® GFCI IN-LINE Cord Sets | ||||||
| TRC-26020-002 | - | 120V/15A | 14/3 AWG | 2 ft | 0.74 lb | |
| TRC-26020-007 | - | 120V/15A | 14/3 AWG | 6 ft | 0.85 lb | |
| TRC-26020-124 | - | 120V/15A | 14/3 AWG | 25 ft | 2.33 lbs | |
| TRC-26020-050 | - | 120V/15A | 14/3 AWG | 50 ft | 4.28 lbs | |
| TRC-26020-099 | - | 120V/15A | 14/3 AWG | 100 ft | 9.8 lbs | |
| TRC-26020-121 | Lighted | 120V/15A | 14/3 AWG | 2 ft | 0.74 lb | |
| TRC-26020-011 | - | 120V/15A | 12/3 AWG | 2 ft | 0.54 lb | |
| TRC-26020-016 | - | 120V/15A | 12/3 AWG | 6 ft | 1.32 lbs | |
| TRC-26020-125 | - | 120V/15A | 12/3 AWG | 25 ft | 4.31 lbs | |
| TRC-26020-150 | - | 120V/15A | 12/3 AWG | 50 ft | 8.23 lbs | |
| TRC-26020-115 | Lighted | 120V/15A | 12/3 AWG | 2 ft | 0.74 lb | |
| TRC-25080-011 | - | 120V/20A | 12/3 AWG | 2 ft | 0.5 lb | |
| TRC-25080-016 | - | 120V/20A | 12/3 AWG | 6 ft | 1.32 lbs | |
| TRC-25080-025 | - | 120V/20A | 12/3 AWG | 25 ft | 4.31 lbs | |
| TRC-25090-001 | - | 240V/15A | 14/3 AWG | 2 ft | 0.74 lb | |
| TRC-25090-006 | - | 240V/15A | 14/3 AWG | 6 ft | 0.85 lb | |
| TRC-25090-025 | - | 240V/15A | 14/3 AWG | 25 ft | 2.33 lbs | |
| TRC-26000-001 | - | 240V/20A | 12/3 AWG | 2 ft | 0.74 lb | |
| TRC-26000-016 | - | 240V/20A | 12/3 AWG | 6 ft | 1.32 lbs | |
| TRC-26000-125 | - | 240V/20A | 12/3 AWG | 25 ft | 4.31 lbs | |
| TRC® ShockShield® GFCI Protected IN-LINE Tri-Cord Plug | ||||||
| TRC-26020-008 | - | 120V/15A | n/a | 2 ft | 1.25 lbs | |
| TRC-26020-147 | - | 120V/15A | n/a | 25 ft | 4.5 lbs | |
| TRC-26020-148 | - | 120V/15A | n/a | 50 ft | 8.35 lbs | |
| TRC-26020-146 | Lighted | 120V/15A | n/a | 2 ft | 1.3 lbs | |
| TRC® ShockShield® GFCI IN-LINE Cord Sets with Molded Locking Connectors | ||||||
| TRC-26020-097 | - | 120V/15A | 14/3 AWG | 2 ft | 1 lb | |
| TRC-25080-136 | - | 120V/20A | 12/3 AWG | 2 ft | 1 lb | |
| TRC-25080-137 | - | 120V/20A | 12/3 AWG | 6 ft | 2 lbs | |
| TRC® ShockShield® GFCI IN-LINE Cord Sets with Mechanical Locking Plug & Connectors | ||||||
| TRC-44700-004 | - | 120V/30A | 10/3 AWG | 2 ft | 1.25 lbs | |
| TRC-44700-005 | - | 120V/30A | 10/3 AWG | 6 ft | 2.4 lbs | |
| TRC-44700-006 | - | 120V/30A | 10/3 AWG | 25 ft | 7.7 lbs | |
| TRC-44720-012 | - | 240V/30A | 10/3 AWG | 3 ft | 1.25 lbs | |
| TRC-44720-013 | - | 240V/30A | 10/3 AWG | 6 ft | 2.4 lbs | |
| TRC-44720-020 | Lighted | 240V/30A | 10/3 AWG | 25 ft | 7.7 lbs | |
RELATED ARTICLES
- Introduction to Power Distribution and System Grounding
- Safety Guide for Conference Room Power Distribution
- Three-Phase Electric Power
- What is a UPS?



Facebook Comments