Your Signamax Connectivity Systems Hardened Ethernet Switch will provide you with the resource you need for transparent bridging connection (multiple network segments with forwarding based on MAC addresses) at full wire speed. |
- Small and economical yet delivers full wire speed switching capability
- An affordable solution for outdoor environments, industrial floor shops, or multi-tenant dwellings applications
- Several models to chose from allow you to get exactly what you need for every application
- Meets NEMA TS1 and TS2 Environmental Requirements for Traffic Control Equipment.
- Meets IEC61000-6-2 EMC Generic Standard Immunity for Industrial Environment.
- UL 1604 Class 1, Division 2 Classified for use in hazardous locations.
- 10/100 Mbps – Full/Half Duplex, Auto-Negotiation, Auto-MDIX.
- 2048 MAC Addresses, 768K bits Buffer Memory, Full Wire-Speed Performance.
- Alarms for Power Failure and Port Link Failure via Relay Output.
- Redundant 1.5 Amp rated, 24 V DC Terminal Block Power Inputs.
(120-240V AC hardened external power supply sold separately.) - Supports DIN-rail or Panel Mount installations.
- 5-year manufacturer warranty
As with any electrical device, place the switch in a cool, dry environment where it will not be subjected to electromagnetic interference. Specifically, the site you select should meet the following requirements:
- Less than 95% relative humidity, non-condensing
- Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards
- Ventilation is adequate, no blocking the ventilation holes on each side of the switch
- The power outlet should be within 1.8 meters of the switch
| APPLICABLE STANDARDS | |
| IEEE 802.3 10BaseT IEEE 802.3u 100BaseTX / 100BaseFX IEEE 802.3x Flow Control and Back pressure |
|
| FIXED PORTS | |
| All Models: | 5 (model 065-7405TB) or 8 (models 065-7408ATB, 065-74091FXSCTB, and |
|---|---|
| Models 065-74091FXSCTB and 065-74091FXSTTB:: | 1 100BaseFX port, 2 km Span, with SC Multimode (model 065-74091FXSC) or ST Multimode (model 065-74091FXST) connectors. |
| SWITCH ARCHITECTURE | |
| Store and Forward; 768 kbits Buffer Memory; 2,048 MAC Addresses |
|
| PERFORMANCE | |
| Forwarding Rate: | 14,880 pps for 10 Mbps, 148,810 pps for 100 Mbps |
| Latency: | less than 7.1 μs |
| LED STATUS INDICATORS | |
| Global: | Power1 (Green), Power2 (Green), Fault (Red) |
| 10/100BaseT/TX: | Link/Activity (Green), 100 Mbps Speed (Amber) |
| 100BaseFX Port (Models 065-74091FXSCTB and 065-74091FXSTTB): |
Link/Activity (Green), 100 Mbps Speed (Amber) |
| POWER INPUT REQUIREMENTS | |
| Redundant 10 to 48 Volts DC Terminal Block. Optional hardened power supply sold separately. | |
| POWER CONSUMPTION | |
| 12 V DC @ 0.99 A, 24 V DC @ 0.55 A, 48 V DC @ 0.39 A; 18.72 Watts Maximum. | |
| INSTALLATION | |
| Included DIN-rail mount. Optional wall mounting bracket available by special order | |
| ENVIRONMENTAL CHARACTERISTICS | |
| Operating Temperature: | -40°F to 167°F (-40°C to 75°C) |
| Storage Temperature: | -50°F to 200°F (-45°C to 93 °C) |
| Operating Humidity: | 10 to 95% (non-condensing) |
| PHYSICAL CHARACTERISTICS & CERTIFICATIONS | |
| Dimensions & Weight: | 1.97 in. x 5.35 in. x 4.33 in., W x H x D (50 mm x 136 mm x 110 mm); 1.76 lb (0.8 kg.) |
| Housing: | IP-30 protection, metal case |
| ESD Standards (IEC 61000-4-2): | Enclosure Contact: + / - 4KV; Criteria B; Enclosure Air: + / - 8KV; Criteria B |
| Radiated FRI Standards (IEC 61000-4-3): | Enclosure Ports: 10V/m, 80 to 1000MHz; Criteria A |
| Burst Standards (IEC 61000-4-4): | Enclosure Ports: + / - 4KV @ 2.5 KHz; Criteria B; |
| Surge Standards (IEC 61000-4-5): | Signal Ports: + / - 1KV; Line-to-earth; Criteria B |
| Induced RFI Standards (IEC 61000-4-6): | Signal Ports: 10V @ 0.15 - 80MHz; Criteria A |
| Magnetic Field Standards (IEC 61000-4-8): | Enclosure Ports: 30A/m @ 50, 60Hz; Criteria A |
| Voltage Dip Standards (IEC 61000-4-11): | A.C. Power Ports: 30% Reduction for 0.5 period; Criteria B |
| Environmental Test Compliance: | (IEC 60068-2-6) Vibration Resistance: 5G @ 150Hz; Criterion 3 (Operation/Storage/Transport) (IEC 60068-2-27) Shock: 25G @ 11ms (Half-Sine Shock Pulse; Operation); 50G @ 11ms (Half-Sine Shock Pulse; Storage/Transport) (IEC 60068-2-32) Free Fall: 1M (3.281ft.) |
| NEMA TS1/2 Environmental requirements for traffic control equipment | |
| EMISSIONS | |
| FCC Class A, Part 15 CE EN6100-6-2, CE EN6100-6-3 | |
| SAFETY | |
| UL 1604: | Classified for ITE Equipment for use in hazardous locations: Class 1, Division 2 group A, B, C, & D: Temp Code T4A; -25°C < Tamb < 74°C |
| UL 60950: | EN 60950, IEC 60950, IEC 61000-6-2 |
The following table lists the pinout of 10/100BaseT/TX ports:
| PIN | REGULAR PORTS | UPLINK PORT |
| 1 | Input Receive Data + | Output Transmit Data + |
| 2 | Input Receive Data - | Output Transmit Data - |
| 3 | Output Transmit Data + | Input Receive Data + |
| 4 | NC | NC |
| 5 | NC | NC |
| 6 | Output Transmit Data - | Input Receive Data - |
| 7 | NC | NC |
| 8 | NC | NC |
| PART # | DESCRIPTION | DIMENSION | WEIGHT | PRICE |
| SX-065-7405TB | Unmanaged Hardened Switch with 5 10/100BaseT/TX ports, 24 V DC Redundant Power Terminal Block | 1.97" W x 5.35" H x 4.33" D (50 mm x 136 mm x 110 mm) |
1.76 lbs (0.8 kg.) | |
| SX-065-7408ATB | Unmanaged Hardened Switch with 8 10/100BaseT/TX ports, 24 V DC Redundant Power Terminal Block | |||
| SX-065-74091FXSCTB | Unmanaged Hardened Switch with 8 10/100BaseT/TX ports + 1 100BaseFX, SC Multimode port, 2 km Span, 24 V DC Redundant Power Terminal Block |
|||
| SX-065-74091FXSTTB | Unmanaged Hardened Switch with 8 10/100BaseT/TX ports + 1 100BaseFX, ST Multimode port, 2 km Span, 24 V DC Redundant Power Terminal Block (Singlemode models available by special order.) |
MANUALS -
| EU EMC Generic Immunity Standards |
||||
| Basic Standards | EN 50082-2: 1995 | EN 61000-6-2: 1999 | EN 50082-1: 1997 | Performance Criteria |
| EN 61000-4-2/ IEC 61000-4-2 |
±4-kV contact discharge ±8-kV air discharge |
±4-kV contact discharge ±8-kV air discharge |
±4-kV contact discharge ±8-kV air discharge |
B |
| EN 61000-4-3 with A1: 1998/ IEC 61000-4-3 with A1: 1998 |
80 to 1,000 MHz, 10 V/m 80% AM w/1-kHz sine wave 800 to 960 MHz (A1: 1998) 1.4 to 2.0 GHz (A1: 1998) |
80 to 87 MHz, 10 V/m 87 to 108 MHz, 3 V/m 108 to 174 MHz, 10 V/m 174 to 230 MHz, 3 V/m 230 to 470 MHz, 10 V/m 470 to 790 MHz, 3 V/m 790 to 1,000 MHz, 10 V/m 80% AM w/1-kHz sine wave 800 to 960 MHz (A1: 1998) 1.4 to 2.0 GHz (A1: 1998) |
80 to 1,000 MHz 80% AM w/1-kHz sine wave 800 to 960 MHz (A1: 1998) 1.4 to 2.0 GHz (A1: 1998) 3 V/m |
A |
| EN 61000-4-4/ IEC 61000-4-4 |
±1-kV signal ports ±1-kV DC power ports ±2-kV AC power ports ±2-kV process control ports |
±1-kV signal ports ±2-kV DC power ports ±2-kV AC power ports (Process control ports treated as signal ports) |
±0.5-kV signal ports ±0.5-kV DC power ports ±1.0-kV AC power ports (Process control ports treated as signal ports) |
B |
| EN 61000-4-5/ IEC 61000-4-5 |
N/A | Signal: ±1-kV line-to-earth DC Power: ±0.5-kV line-to-earth DC Power: ±0.5-kV line-to-line AC Power: ±2-kV line-to-earth AC Power: ±1-kV line-to-line |
(Signal port testing not required) DC Power: ±0.5-kV line-to-earth DC Power: ±0.5-kV line-to-line AC Power: ±2-kV line-to-earth AC Power: ±1-kV line-to-line |
B |
| EN 61000-4-6/ IEC 61000-4-6 |
0.15 to 80 MHz, 10 Vrms 80% AM w/1-kHz sine wave | 0.15 to 47 MHz, 10 Vrms 47 to 68 MHz, 3 Vrms 68 to 80 MHz, 10 Vrms 80% AM w/1-kHz sine wave |
0.15 to 80 MHz, 3 Vrms 80% AM w/1-kHz sine wave | A |
| EN 61000-4-8/ IEC 61000-4-8 |
50 Hz, 30 A/m | 50 Hz or 60 Hz, 30 A/m | 50 Hz, 3 A/m | A |
| EN 61000-4-11/ IEC 61000-4-11 |
N/A | 30% reduction; 10 ms 60% reduction; 100 ms 1,000 ms >95% reduction; 5,000 ms |
30% reduction; 10 ms 60% reduction; 100 ms >95% reduction; 5,000 ms |
B C C |