Home > Test Equipment > Fiber Optic Testers & Kits > KI 3800 Series OLS
Kingfisher KI 3800 Series Optical Light Source
Test Multi-Wavelength Loss in Singlemode And Multimode Fiber Optic Systems
Kingfisher KI 3800 Series Optical Light Source
This requires one or more of the following: javascript enabled, Flash Video Player, and Quicktime or Windows Media Player |
What's special about KI 3800 Series?
|
- Compact, rugged, shock absorbent and light weight
- Supplied with metal free SC, ST, FC interchangeable optical connectors including SFF styles
- Excellent optical power stability
- Test all types of fiber optic systems for: Tx/Rx absolute power levels in dBm, optical loss in dB and continuity witht the test tone feature
- Single mode 1310, 1490, 1550, 1625 nm laser options
- Multimode 850, 1300 nm LED options with improved repeatability and standards compliance
- Multimode 850 nm VCSEL laser option
- NEW POF 660 nm LED option
- Superior re-connection repeatability, < 0.1 dB for more accurate measurement results
- Calibration can be performed by any well equipped laboratory without opening the instrument
- 600 hours alkaline battery life
- Supplied with metal free SC, ST, FC interchangeable connectors. Other options include LC connectors
- 3 year warranty and calibration cycle
- Excellent re-connection repeatability
- Low skill operation
- Optical test tone generator function
- EMC, CE, FCC and C-Tick compliant
- IEC 61315/TIA-455-231 compliant
- NATA, ILAC, ISO17025
- 3 year warranty
The KI 3800 series Optical Light source is used for testing loss in optical fiber systems, at 1 to 2 wavelengths on singlemode and multimode fiber cable. This model has the capability of one button automated multi-wavelength loss testing when used with an autotest compatible power meter or loss test set. The test tone function of the 3800 Optical Light Source can be used with a compatible Power Meter or clip-on identifier to test fiber continuity, route location or to find a fault.
The multimode LED emitters are optionally compliant with TIA/IEC standards for Coupled Power Ratio (CPR), center wavelength and spectral width. All emitters are fiber connected to improve stability.
Interchangeable optical connectors work well for both 1.25 mm SFF (small form factor) and 2.5 mm connectors alike. Like other Kingfisher products the connectors are dust and drop protected and the testers come with 3 popular connector adaptor styles.
View KI 3800 Technical Specifications -
PDF
View Kingfisher Comparison Chart
General Specifications
| Connectors | The interchangeable optical connectors are drop and dust protected during use by a snap-on cover and are easily disassembled for cleaning |
|---|---|
| Re-calibration cycle | 3 years |
| Battery life | 600 hours at Autotest |
| Size | 6.5"x4.7"x1.6" (165mm x 120mm x 40mm) |
| Net weight | 0.35kg, 0.8 lb |
| Shipping weight | 0.7kg, 1.5 lbs |
| Operating temperature | -15° to +55°C |
| Storage temperature | -25° to +70°C |
| Casing | Polycarbonate, shock absorbent corners, 1 meter drop tested |
| Power | 2 alkaline C cells (7.6 A/hr) or 2 AA cells using AA-to-C converter (OPT146) |
| Selectable auto-off and low battery indicator | |
| Calibration | Performed without opening instrument |
| Display | 4-digit high contrast LCD |
| Resolution | Log: 0.01 dB |
| Linear: 3 digits (100-999) or 0.01 nW | |
| Tone detection | 150 9999 Hz ± 1% |
| Laser | InGaAs Fabry-Perot |
| Wavelength: 1310/1550 ± 20nm | |
| LED | Surface Emitting |
| Wavelength: 850/1300 ± 20nm | |
| Max CW output power | 1.26 mW |
| Beam waist diameter | 9µm |
| Numerical aperture | 0.1 |
| Laser Class according to IEC 60825-1 (2001 international) | 1 |
| Maximum permissible CW output power IEC 60825-1 (2001 international) | 10 mW |
| Laser Class according to FDA CFR 21 1040.10 (1995 USA) | 1 |
| Maximum permissible CW output power CFR 21 1040.10 (1995 USA) | 8.1 mW |
Compliance
| Standard | Comment |
|---|---|
| CE | CE rated, low voltage directive 73/23/EEC, EMC directive 89/336/EEC, amended by 93/68/EEC |
| Directive 2002/95/EC on restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) | |
| Directive 2002/96/EEC on waste electrical and lectronic equipment (WEEE) | |
| MIL-PRF-28800F | 1996 performance specification -Test equipment for use with electrical and electronic equipment , general specification IEC 60529: 2001/EN 60529: 1993+A1:2003 Degrees of protection provided by enclosures |
| FCC | Registration number 90891 |
| IEC | 60825-1:2001 |
| CFR | CFR 21 part 1040.10 (USA) CFR 47 FCC Part 15, Subpart B (Class B) (USA) |
| ANSI/TIA/EIA | 526-14-A: Optical power loss measurements of installed multimode fiber cable plant, 1998 |
| Default requirements | Use LED sources with specific CPR, center wavelength and spectral width characteristics |
| Tests may require one or both 850/1300 nm wavelengths | |
| Use a 2-way or bi-directional measurement procedure |
Light Source Specifications
| General | 1310-1550 Laser | Other Laser | LED | Comment |
| Output Power, dB | 0 | -4 | -23 to 62.5•m -10 to 1mm |
±1 dB |
| Short Term Stability, dB | 0.04 (ORL < -25 dB) |
0.06 | 0.01 | for 15 mn, typical |
| Stability Over Temperature , dB | 0.6 | 0.6 | 0.35 | typical, over temperature |
| λ Initial Tolerance, nm | 20 | 20 | 30 | at 25°C |
| λ Width, nm | 3 | <1 | 35/100 850/1300 |
FHWM, typical |
| λ nm/ °C | 0.4 | 0.1 | 0.4 | typical |
| Coupled Power Ratio (CPR) | - | - | CPR CAT 1 into 50µm* | 850 nm: 20 -24 dB 1300 nm: 16 - 20 dB |
| Reconnection, Repeatibility, dB | 0.1 | 0.05 | 95% confidence | |
| Modulation | 270 Hz, 1 KHz, 2 KHz, ±2% | |||
| Laser Output | 3 dB in 0.05 dB steps | |||
Note:* CPR CAT 1 into 50µm per TIA/EIA 52614A and IEC 61280-4-1
Ships within 2-3 weeks
| Part # | Description | PRICE |
| KI-3810-MP | Optical Light Source, 850 nm LED, Blister Pack | |
| KI-3812-MP | Optical Light Source, 850 / 1300 nm LED, Blister Pack | |
| KI-3820-MP | Optical Light Source, 1310 nm, PC, Blister Pack | |
| KI-3822-APC-MP | Optical Light Source, 1310 / 1550 nm, APC, Blister Pack | |
| KI-3822-MP | Optical Light Source, 1310 / 1550 nm PC, Blister Pack | |
| Accessories | ||
| KI-OPT060 | Connector Adaptor, Ceramic Sleeve, SC/E2000 Blue | |
| KI-OPT060G | Connector Adaptor, Ceramic Sleeve, SC/E2000 Green | |
| KI-OPT071 | Connector Adaptor, Ceramic Sleeve, SC/LSA,DIN Blue | |
| KI-OPT072 | Connector Adaptor, Ceramic Sleeve, SC/LC | |
| KI-OPT080 | Connector Adaptor, Ceramic Sleeve, SC/MU | |
| KI-OPT082 | Connector Adaptor, SMA 905/906 | |
| KI-OPT091 | #TIA/IEC standard compliance | |
| KI-OPT146 | Accessory Pack for KI3000 series (Soft pouch, Leather holster, 1.25 and 2.5mm clean stick, Connector clean cloth, AA-to-C battery converter) | |
| KI-OPT153 | Carry Case for 2 Instruments | |
- Laser sources at 1310/1550 nm are used for testing single mode fiber
- LED sources at 850/1300 nm are used for testing multi mode fiber
- The 1300 nm LED can also perform testing on short distance singlemode fiber
RELATED ARTICLES -
HOW-TO CORNER -