Home > Cables > Electrical Wires > IGUS® CF6
IGUS Chainflex® Shielded PVC Control Cable
Economy Grade Shielded Control Cable for Automated Equipment and Heavy Machinery
![]()
IGUS® Chainflex® CF6 Shielded PVC Control Cables
This requires one or more of the following: javascript enabled, Flash Video Player, and Quicktime or Windows Media Player
|
What's special about these economical PVC control cables?
As robotics, milling, and CNC machinery become faster and more advanced, higher levels of stress and friction can result, and standard cabling becomes inadequate. As an answer to this problem, IGUS®, a world leader in Energy Chain Systems®, has developed a new line of power and data cables that can withstand the grueling rigors and friction caused by the constant movement of automated machinery and its components. The Chainflex® CF6 line of Shielded PVC Control Cables is designed to provide installers and machine operators with a reliable cabling solution for control mechanisms that can withstand friction, stress, machine oil, and damaging UV rays in indoor or outdoor applications. |
- Conductors are made from finely stranded bare copper wires that provide reliable power and performance in accordance with EN 60228
- Individual conductors are coated in a high-quality, mechanical grade PVC-insulating compound that protects bare copper from corrosion prior to installation, and reduces crosstalk after termination
- Gusset filled, intermediate jacket is made of a pressure extruded PVC-based, low-adhesion blend that keeps the inner core securely bundled for promoting higher tensile strength, while maintaining a high degree of flexibility
- Overall Shield is constructed from a highly flexible tinned copper braid, which reduces the effects of outside interferences, and acts as a second level of defense if the outer jacket becomes worn or damaged
- Durable outer jacket is made from an oil-resistant, PVC-based blend that has been adapted to the rigors and friction found inside cable/hose carrier systems
- Outer jacket is Silicon-free in compliance with PV 3.10.7 – status 1992
- Flame rating FT1
- RoHS compliant
- cRUus rated
- CE rated
Chainflex Cables Chemical Resistance Chart
| TECHNICAL DATA | |
| Minimum Bending Radius, moving | < 10m travel = 6.8 x outer diameter; ≥ 10m travel = 7.5 x outer cable diameter |
| Minimum Bending Radius, fixed | 4 x outer cable diameter |
| Permissible Temperature, moving | +23° F to +158° F (-5° C to +70° C) |
| Permissible Temperature, fixed | -4° F to +158° F (-20° C to +70° C) |
| Voltage | 300V 24-16 AWG, 600V 14 AWG |
| Testing Voltage | 2000 Volts |
| Oil Resistance | Medium |
| UV Resistance | Medium |
| REGULATIONS | |
| cRUus | UL AWM Style for USA & Canada: 2464 80° C 20-16 AWG; 2570 80° C 14 AWG |
| Flame Resistance | FT1 |
| VDE | Compliant |
| CE | Compliant |
| RoHS | Compliant |
| Conductor Colors | 20-16 AWG: Black with White numbers, one conductor green-yellow 20-16 AWG |
| 24 AWG: DIN 47100 | |
| lbs/mft = pounds per thousand feet | |
| PART # | AWG | Number of Conductors and Rated Cross-Section in mm² | OUTER DIAMETER (approx) | Copper Index | Weight | |||
| inches | mm | lbs/mft | kg/km | lbs/mft | kg/km | |||
| IGU-CF6-02-04 | 24 | 4 x 0.25 | 0.28" | 7 | 19 | 28 | 37.4 | 55 |
| IGU-CF6-02-24 | 24 | 24 x 0.25 | 0.23" | 13.5 | 68 | 100 | 170 | 250 |
| IGU-CF6-05-05 | 20 | 5 x 0.5 | 0.35" | 9 | 32.6 | 48 | 77.5 | 114 |
| IGU-CF6-05-07 | 20 | 7 x 0.5 | 0.43" | 11 | 42.8 | 63 | 96.6 | 142 |
| IGU-CF6-05-09 | 20 | 9 x 0.5 | 0.49" | 12.5 | 52.4 | 77 | 123.8 | 182 |
| IGU-CF6-05-12 | 20 | 12 x 0.5 | 0.51" | 13 | 63.2 | 93 | 160.5 | 206 |
| IGU-CF6-05-18 | 20 | 18 x 0.5 | 0.59" | 15 | 81.6 | 120 | 163.2 | 276 |
| IGU-CF6-05-24 | 20 | 24 x 0.5 | 0.67" | 17 | 129.2 | 190 | 275.4 | 405 |
| IGU-CF6-07-03 | 18 | 3 x 0.75 | 0.33" | 8.5 | 35.4 | 52 | 74.8 | 110 |
| IGU-CF6-07-04 | 18 | 4 x 0.75 | 0.35" | 9 | 36.7 | 54 | 81.6 | 120 |
| IGU-CF6-07-05 | 18 | 5 x 0.75 | 0.39" | 10 | 49.6 | 3 | 102 | 150 |
| IGU-CF6-07-07 | 18 | 7 x 0.75 | 0.47" | 12 | 63.2 | 93 | 129.2 | 190 |
| IGU-CF6-07-12 | 18 | 12 x 0.75 | 0.55" | 14 | 93.8 | 138 | 179.5 | 264 |
| IGU-CF6-07-18 | 18 | 18 x 0.75 | 0.69" | 17.5 | 138.7 | 204 | 278.8 | 410 |
| IGU-CF6-07-24 | 18 | 24 x 0.75 | 0.71" | 18 | 170 | 250 | 316.9 | 466 |
| IGU-CF6-10-03 | 17 | 3 x 1 | 0.33" | 8.5 | 41.5 | 61 | 70 | 103 |
| IGU-CF6-10-04 | 17 | 4 x 1 | 0.33" | 8.5 | 51 | 75 | .78.2 | 115 |
| IGU-CF6-10-05 | 17 | 5 x 1 | 0.43" | 11 | 59.2 | 87 | 115.6 | 170 |
| IGU-CF6-10-07 | 17 | 7 x 1 | 0.51" | 13 | 76.8 | 113 | 147.6 | 217 |
| IGU-CF6-10-12 | 17 | 12 x 1 | 0.59" | 15 | 116.3 | 171 | 212.8 | 313 |
| IGU-CF6-10-18 | 17 | 18 x 1 | 0.73" | 18.5 | 177.5 | 261 | 319.6 | 470 |
| IGU-CF6-10-24 | 17 | 24 x 1 | 0.83" | 21 | 208.8 | 307 | 399.8 | 588 |
| IGU-CF6-15-03 | 16 | 3 x 1.5 | 0.39" | 10 | 55.1 | 81 | 105.4 | 155 |
| IGU-CF6-15-04 | 16 | 4 x 1.5 | 0.41" | 10.5 | 57.8 | 85 | 115.6 | 170 |
| IGU-CF6-15-05 | 16 | 5 x 1.5 | 0.43" | 11 | 72.1 | 106 | 129.2 | 190 |
| IGU-CF6-15-07 | 16 | 7 x 1.5 | 0.55" | 14 | 104 | 153 | 183.6 | 270 |
| IGU-CF6-15-12 | 16 | 12 x 1.5 | 0.71" | 18 | 157.8 | 232 | 279.5 | 411 |
| IGU-CF6-15-18 | 16 | 18 x 1.5 | 0.87" | 22 | 249.6 | 367 | 433.2 | 637 |
| IGU-CF6-15-25 | 16 | 25 x 1.5 | 0.96" | 24.5 | 334.6 | 492 | 556.9 | 819 |
| IGU-CF6-25-04 | 14 | 4 x 2.5 | 0.49" | 12.5 | 91.8 | 135 | 187 | 275 |
All Cuts Under 200 FEET in length are Non-Returnable / Non-Refundable
All returns are subject to a restocking fee. Goods not in resaleable condition will not be accepted
| PART # | NUMBER OF CONDUCTORS | CONDUCTOR AWG | OUTER DIAMETER (approx.) | WEIGHT per FT | PRICE per FT |
| IGU-CF6-02-04 | 4 | 24 | 0.28" | 0.037 lb | |
| IGU-CF6-02-24 | 24 | 24 | 0.53" | 0.170 lb | |
| IGU-CF6-05-05 | 5 | 20 | 0.35" | 0.076 lb | |
| IGU-CF6-05-07 | 7 | 20 | 0.43" | 0.097 lb | |
| IGU-CF6-05-09 | 9 | 20 | 0.49" | 0.124 lb | |
| IGU-CF6-05-12 | 12 | 20 | 0.51" | 0.161 lb | |
| IGU-CF6-05-18 | 18 | 20 | 0.59" | 0.163 lb | |
| IGU-CF6-05-24 | 24 | 20 | 0.67" | 0.275 lb | |
| IGU-CF6-07-03 | 3 | 18 | 0.33" | 0.075 lb | |
| IGU-CF6-07-04 | 4 | 18 | 0.35" | 0.082 lb | |
| IGU-CF6-07-05 | 5 | 18 | 0.39" | 0.102 lb | |
| IGU-CF6-07-07 | 7 | 18 | 0.47" | 0.129 lb | |
| IGU-CF6-07-12 | 12 | 18 | 0.55" | 0.180 lb | |
| IGU-CF6-07-18 | 18 | 18 | 0.69" | 0.279 lb | |
| IGU-CF6-07-24 | 24 | 18 | 0.71" | 0.317 lb | |
| IGU-CF6-10-03 | 3 | 17 | 0.33" | 0.070 lb | |
| IGU-CF6-10-04 | 4 | 17 | 0.33" | 0.078 lb | |
| IGU-CF6-10-05 | 5 | 17 | 0.43" | 0.116 lb | |
| IGU-CF6-10-07 | 7 | 17 | 0.51" | 0.148 lb | |
| IGU-CF6-10-12 | 12 | 17 | 0.59" | 0.213 lb | |
| IGU-CF6-10-18 | 18 | 17 | 0.73" | 0.320 lb | |
| IGU-CF6-10-24 | 24 | 17 | 0.83" | 0.400 lb | |
| IGU-CF6-15-03 | 3 | 16 | 0.39" | 0.105 lb | |
| IGU-CF6-15-04 | 4 | 16 | 0.41" | 0.116 lb | |
| IGU-CF6-15-05 | 5 | 16 | 0.43" | 0.129 lb | |
| IGU-CF6-15-07 | 7 | 16 | 0.55" | 0.184 lb | |
| IGU-CF6-15-12 | 12 | 16 | 0.71" | 0.280 lb | |
| IGU-CF6-15-18 | 18 | 16 | 0.87" | 0.433 lb | |
| IGU-CF6-15-25 | 25 | 16 | 0.96" | 0.557 lb | |
| IGU-CF6-25-04 | 4 | 14 | 0.49" | 0.187 lb |
MANUALS & USER GUIDES -
RELATED ARTICLES -
- The Facts on American Wire Gauge (AWG)
- How to Choose the Right Cable Ties
- 10 Easy Ways to Protect Against Electrical Hazards
- CableOrganizer.com’s Top 10 Products for Fire Protection



Electrical Hook-Up Wire - Omni Cable
IGUS® E08 Series E-Z Chain®
IGUS® E-Chain® Series 15 Zipper