IGUS Chainflex® Shielded PVC Control Cable
Economy Grade Shielded Control Cable for Automated Equipment and Heavy Machinery
![]()
Close Window
IGUS® Chainflex® CF6 Shielded PVC Control Cables
This requires one or more of the following: javascript enabled, Flash Video Player, and Quicktime or Windows Media Player
|
As robotics, milling, and CNC machinery become faster and more advanced, higher levels of stress and friction can result, and standard cabling becomes inadequate. As an answer to this problem, IGUS®, a world leader in Energy Chain Systems®, has developed a new line of power and data cables that can withstand the grueling rigors and friction caused by the constant movement of automated machinery and its components. The Chainflex® CF6 line of Shielded PVC Control Cables is designed to provide installers and machine operators with a reliable cabling solution for control mechanisms that can withstand friction, stress, machine oil, and damaging UV rays in indoor or outdoor applications. |
- Conductors are made from finely stranded bare copper wires that provide reliable power and performance in accordance with EN 60228
- Individual conductors are coated in a high-quality, mechanical grade PVC-insulating compound that protects bare copper from corrosion prior to installation, and reduces crosstalk after termination
- Gusset filled, intermediate jacket is made of a pressure extruded PVC-based, low-adhesion blend that keeps the inner core securely bundled for promoting higher tensile strength, while maintaining a high degree of flexibility
- Overall Shield is constructed from a highly flexible tinned copper braid, which reduces the effects of outside interferences, and acts as a second level of defense if the outer jacket becomes worn or damaged
- Durable outer jacket is made from an oil-resistant, PVC-based blend that has been adapted to the rigors and friction found inside cable/hose carrier systems
- Outer jacket is Silicon-free in compliance with PV 3.10.7 – status 1992
- Flame rating FT1
- RoHS compliant
- cRUus rated
- CE rated
Chainflex Cables Chemical Resistance Chart
| TECHNICAL DATA | |
| Minimum Bending Radius, moving | < 10m travel = 6.8 x outer diameter; ≥ 10m travel = 7.5 x outer cable diameter |
| Minimum Bending Radius, fixed | 4 x outer cable diameter |
| Permissible Temperature, moving | +23° F to +158° F (-5° C to +70° C) |
| Permissible Temperature, fixed | -4° F to +158° F (-20° C to +70° C) |
| Voltage | 300V 24-16 AWG, 600V 14 AWG |
| Testing Voltage | 2000 Volts |
| Oil Resistance | Medium |
| UV Resistance | Medium |
| REGULATIONS | |
| cRUus | UL AWM Style for USA & Canada: 2464 80° C 20-16 AWG; 2570 80° C 14 AWG |
| Flame Resistance | FT1 |
| VDE | Compliant |
| CE | Compliant |
| RoHS | Compliant |
| Conductor Colors | 20-16 AWG: Black with White numbers, one conductor green-yellow 20-16 AWG |
| 24 AWG: DIN 47100 | |
| lbs/mft = pounds per thousand feet | |
| PART # | AWG | Number of Conductors and Rated Cross-Section in mm² | OUTER DIAMETER (approx) | Copper Index | Weight | |||
| inches | mm | lbs/mft | kg/km | lbs/mft | kg/km | |||
| IGU-CF6-02-04 | 24 | 4 x 0.25 | 0.28" | 7 | 19 | 28 | 37.4 | 55 |
| IGU-CF6-02-24 | 24 | 24 x 0.25 | 0.23" | 13.5 | 68 | 100 | 170 | 250 |
| IGU-CF6-05-05 | 20 | 5 x 0.5 | 0.35" | 9 | 32.6 | 48 | 77.5 | 114 |
| IGU-CF6-05-07 | 20 | 7 x 0.5 | 0.43" | 11 | 42.8 | 63 | 96.6 | 142 |
| IGU-CF6-05-09 | 20 | 9 x 0.5 | 0.49" | 12.5 | 52.4 | 77 | 123.8 | 182 |
| IGU-CF6-05-12 | 20 | 12 x 0.5 | 0.51" | 13 | 63.2 | 93 | 160.5 | 206 |
| IGU-CF6-05-18 | 20 | 18 x 0.5 | 0.59" | 15 | 81.6 | 120 | 163.2 | 276 |
| IGU-CF6-05-24 | 20 | 24 x 0.5 | 0.67" | 17 | 129.2 | 190 | 275.4 | 405 |
| IGU-CF6-07-03 | 18 | 3 x 0.75 | 0.33" | 8.5 | 35.4 | 52 | 74.8 | 110 |
| IGU-CF6-07-04 | 18 | 4 x 0.75 | 0.35" | 9 | 36.7 | 54 | 81.6 | 120 |
| IGU-CF6-07-05 | 18 | 5 x 0.75 | 0.39" | 10 | 49.6 | 3 | 102 | 150 |
| IGU-CF6-07-07 | 18 | 7 x 0.75 | 0.47" | 12 | 63.2 | 93 | 129.2 | 190 |
| IGU-CF6-07-12 | 18 | 12 x 0.75 | 0.55" | 14 | 93.8 | 138 | 179.5 | 264 |
| IGU-CF6-07-18 | 18 | 18 x 0.75 | 0.69" | 17.5 | 138.7 | 204 | 278.8 | 410 |
| IGU-CF6-07-24 | 18 | 24 x 0.75 | 0.71" | 18 | 170 | 250 | 316.9 | 466 |
| IGU-CF6-10-03 | 17 | 3 x 1 | 0.33" | 8.5 | 41.5 | 61 | 70 | 103 |
| IGU-CF6-10-04 | 17 | 4 x 1 | 0.33" | 8.5 | 51 | 75 | .78.2 | 115 |
| IGU-CF6-10-05 | 17 | 5 x 1 | 0.43" | 11 | 59.2 | 87 | 115.6 | 170 |
| IGU-CF6-10-07 | 17 | 7 x 1 | 0.51" | 13 | 76.8 | 113 | 147.6 | 217 |
| IGU-CF6-10-12 | 17 | 12 x 1 | 0.59" | 15 | 116.3 | 171 | 212.8 | 313 |
| IGU-CF6-10-18 | 17 | 18 x 1 | 0.73" | 18.5 | 177.5 | 261 | 319.6 | 470 |
| IGU-CF6-10-24 | 17 | 24 x 1 | 0.83" | 21 | 208.8 | 307 | 399.8 | 588 |
| IGU-CF6-15-03 | 16 | 3 x 1.5 | 0.39" | 10 | 55.1 | 81 | 105.4 | 155 |
| IGU-CF6-15-04 | 16 | 4 x 1.5 | 0.41" | 10.5 | 57.8 | 85 | 115.6 | 170 |
| IGU-CF6-15-05 | 16 | 5 x 1.5 | 0.43" | 11 | 72.1 | 106 | 129.2 | 190 |
| IGU-CF6-15-07 | 16 | 7 x 1.5 | 0.55" | 14 | 104 | 153 | 183.6 | 270 |
| IGU-CF6-15-12 | 16 | 12 x 1.5 | 0.71" | 18 | 157.8 | 232 | 279.5 | 411 |
| IGU-CF6-15-18 | 16 | 18 x 1.5 | 0.87" | 22 | 249.6 | 367 | 433.2 | 637 |
| IGU-CF6-15-25 | 16 | 25 x 1.5 | 0.96" | 24.5 | 334.6 | 492 | 556.9 | 819 |
| IGU-CF6-25-04 | 14 | 4 x 2.5 | 0.49" | 12.5 | 91.8 | 135 | 187 | 275 |
All Cuts Under 200 FEET in length are Non-Returnable / Non-Refundable
All returns are subject to a restocking fee. Goods not in resaleable condition will not be accepted
| PART # | NUMBER OF CONDUCTORS | CONDUCTOR AWG | OUTER DIAMETER (approx.) | WEIGHT per FT | PRICE per FT |
| IGU-CF6-02-04 | 4 | 24 | 0.28" | 0.037 lb | |
| IGU-CF6-02-24 | 24 | 24 | 0.53" | 0.170 lb | |
| IGU-CF6-05-05 | 5 | 20 | 0.35" | 0.076 lb | |
| IGU-CF6-05-07 | 7 | 20 | 0.43" | 0.097 lb | |
| IGU-CF6-05-09 | 9 | 20 | 0.49" | 0.124 lb | |
| IGU-CF6-05-12 | 12 | 20 | 0.51" | 0.161 lb | |
| IGU-CF6-05-18 | 18 | 20 | 0.59" | 0.163 lb | |
| IGU-CF6-05-24 | 24 | 20 | 0.67" | 0.275 lb | |
| IGU-CF6-07-03 | 3 | 18 | 0.33" | 0.075 lb | |
| IGU-CF6-07-04 | 4 | 18 | 0.35" | 0.082 lb | |
| IGU-CF6-07-05 | 5 | 18 | 0.39" | 0.102 lb | |
| IGU-CF6-07-07 | 7 | 18 | 0.47" | 0.129 lb | |
| IGU-CF6-07-12 | 12 | 18 | 0.55" | 0.180 lb | |
| IGU-CF6-07-18 | 18 | 18 | 0.69" | 0.279 lb | |
| IGU-CF6-07-24 | 24 | 18 | 0.71" | 0.317 lb | |
| IGU-CF6-10-03 | 3 | 17 | 0.33" | 0.070 lb | |
| IGU-CF6-10-04 | 4 | 17 | 0.33" | 0.078 lb | |
| IGU-CF6-10-05 | 5 | 17 | 0.43" | 0.116 lb | |
| IGU-CF6-10-07 | 7 | 17 | 0.51" | 0.148 lb | |
| IGU-CF6-10-12 | 12 | 17 | 0.59" | 0.213 lb | |
| IGU-CF6-10-18 | 18 | 17 | 0.73" | 0.320 lb | |
| IGU-CF6-10-24 | 24 | 17 | 0.83" | 0.400 lb | |
| IGU-CF6-15-03 | 3 | 16 | 0.39" | 0.105 lb | |
| IGU-CF6-15-04 | 4 | 16 | 0.41" | 0.116 lb | |
| IGU-CF6-15-05 | 5 | 16 | 0.43" | 0.129 lb | |
| IGU-CF6-15-07 | 7 | 16 | 0.55" | 0.184 lb | |
| IGU-CF6-15-12 | 12 | 16 | 0.71" | 0.280 lb | |
| IGU-CF6-15-18 | 18 | 16 | 0.87" | 0.433 lb | |
| IGU-CF6-15-25 | 25 | 16 | 0.96" | 0.557 lb | |
| IGU-CF6-25-04 | 4 | 14 | 0.49" | 0.187 lb |
MANUALS & USER GUIDES -
RELATED ARTICLES -
- The Facts on American Wire Gauge (AWG)
- How to Choose the Right Cable Ties
- 10 Easy Ways to Protect Against Electrical Hazards
- CableOrganizer.com’s Top 10 Products for Fire Protection




Electrical Hook-Up Wire - Omni Cable
IGUS® E08 Series E-Z Chain®
IGUS® E-Chain® Series 15 Zipper
Facebook Comments