The economy line of Chainflex® Data Cables from IGUS®, provide professional installers and industrial machine operators with an affordable means to wire or repair automated components. More |
Designed to be highly flexible while remaining rugged enough to withstand grueling industrial environments, making these data cables are an ideal wiring solution for CNC, robotic, milling, or other automated machinery requiring data connections.
- Inner core consists of 1 to 14 twisted pairs of finely stranded bare copper conductor for creating a stable connection between the controlling mechanism and the machinery
- Conductors are individually insulated with a color-coded, mechanically tough PVC jacket
- Overall shield is made from highly flexible braided copper strands that protect the conductors from electromagnetic interference, and acts as 2nd level of defense in case the outer jacket is breached or worn thin
- Oil-resistant outer jacket is a PVC based, low-adhesion blend that has been adapted to meet the requirements of cable/hose carrier systems
- FT1 flame-retardant rated
- Oil-resistant in accordance with VDE
- UL/CSA voltage rating 300V
- CE Rated
- RoHS compliant
Chainflex Cables Chemical Resistance Chart
| Part # | AWG | Number of Conductors and Rated Cross-Section in mm2 | Outer Diameter (approx) | Copper Index | Weight | Price per Foot | |||
| inches | mm | lbs/mft* | kg/km | lbs/mft | kg/km | ||||
| CF211-02-01-02 | 24 | 1 x 2 x 0.25 | 0.2 | 5 | 10.9 | 16 | 23.8 | 35 | |
| CF211-02-02-02 | 24 | 2 x 2 x 0.25 | 0.28 | 7 | 19 | 28 | 40.8 | 60 | |
| CF211-02-03-02 | 24 | 3 x 2 x 0.25 | 0.3 | 7.5 | 25.2 | 37 | 49.6 | 73 | |
| CF211-02-04-02 | 24 | 4 x 2 x 0.25 | 0.31 | 8 | 29.9 | 44 | 57.8 | 85 | |
| CF211-02-05-02 | 24 | 5 x 2 x 0.25 | 0.33 | 8.5 | 34.7 | 51 | 66 | 97 | |
| CF211-02-06-02 | 24 | 6 x 2 x 0.25 | 0.37 | 9.5 | 39.4 | 58 | 74.8 | 110 | |
| CF211-02-08-02 | 24 | 8 x 2 x 0.25 | 0.45 | 11.5 | 51 | 75 | 108.8 | 160 | |
| CF211-02-10-02 | 24 | 10 x 2 x 0.25 | 0.51 | 13 | 63.2 | 93 | 132.6 | 195 | |
| CF211-02-14-02 | 24 | 14 x 2 x 0.25 | 0.53 | 13.5 | 74.1 | 109 | 139.4 | 205 | |
| CF211-03-03-02 | 22 | 3 x 2 x 0.34 | 0.31 | 8 | 25.2 | 37 | 53.7 | 79 | |
| CF211-05-01-02 | 20 | 1 x 2 x 0.5 | 0.22 | 5.5 | 15.6 | 23 | 34 | 50 | |
| CF211-05-02-02 | 20 | 2 x 2 x 0.5 | 0.31 | 8 | 29.9 | 44 | 54.4 | 80 | |
| CF211-05-03-02 | 20 | 3 x 2 x 0.5 | 0.35 | 9 | 38.8 | 57 | 68 | 100 | |
| CF211-05-04-02 | 20 | 4 x 2 x 0.5 | 0.37 | 9.5 | 46.2 | 68 | 81.6 | 120 | |
| CF211-05-05-02 | 20 | 5 x 2 x 0.5 | 0.43 | 11 | 54.4 | 80 | 98.6 | 145 | |
| CF211-05-06-02 | 20 | 6 x 2 x 0.5 | 0.49 | 12.5 | 67.3 | 99 | 125.8 | 185 | |
| CF211-05-08-02 | 20 | 8 x 2 x 0.5 | 0.55 | 14 | 84.3 | 124 | 156.4 | 230 | |
| CF211-05-10-02 | 20 | 10 x 2 x 0.5 | 0.63 | 16 | 119 | 175 | 217.6 | 320 | |
| CF211-05-14-02 | 20 | 14 x 2 x 0.5 | 0.67 | 17 | 127.1 | 187 | 227.8 | 335 | |
| Technical Data | |||||||||
| Minimum bending radius for flexible use: | 10 x outer cable diameter | ||||||||
| Permissible temperature range for continuous flexing: | 23°F to 158°F (-5°C to +70°C) | ||||||||
| Voltage: | 300V | ||||||||
| Oil resistance: | Medium | ||||||||
| UV resistance: | Medium | ||||||||
| Regulations | |||||||||
| cRUus: | UL AWM 2464 80°C 300V, CSA AWM l/ll A/B 80°C 300V | ||||||||
| Flame resistance: | FT1 | ||||||||
| Compliant | CE, RoHS, VDE | ||||||||
| Conductor colors: | Color code47100 | ||||||||
| * lbs/mft = pounds per thousand feet | |||||||||
All Cuts Under 200 FEET in length are Non-Returnable / Non-Refundable
All returns are subject to a restocking fee. Goods not in resaleable condition will not be accepted
| PART # | NUMBER OF TWISTED CONDUCTOR PAIRS | CONDUCTOR AWG | OUTER DIAMETER (approx) | WEIGHT / Per FT | PRICE PER FOOT |
| IGU-CF211-02-01-02 | 1 Pair / 2 Conductors | 24 | 0.20" | 0.024 lb | |
| IGU-CF211-02-02-02 | 2 Pair / 4 Conductors | 24 | 0.28" | 0.041 lb | |
| IGU-CF211-02-03-02 | 3 Pair / 6 Conductors | 24 | 0.30" | 0.050 lb | |
| IGU-CF211-02-04-02 | 4 Pair / 8 Conductors | 24 | 0.31" | 0.058 lb | |
| IGU-CF211-02-05-02 | 5 Pair / 10 Conductors | 24 | 0.33" | 0.066 lb | |
| IGU-CF211-02-06-02 | 6 Pair / 12 Conductors | 24 | 0.37" | 0.075 lb | |
| IGU-CF211-02-08-02 | 8 Pair / 16 Conductors | 24 | 0.45" | 0.109 lb | |
| IGU-CF211-02-10-02 | 10 Pair / 20 Conductors | 24 | 0.51" | 0.133 lb | |
| IGU-CF211-02-14-02 | 14 Pair / 28 Conductors | 24 | 0.53" | 0.139 lb | |
| IGU-CF211-03-03-02 | 3 Pair / 6 Conductors | 22 | 0.31" | 0.054 lb | |
| IGU-CF211-05-01-02 | 1 Pair / 2 Conductors | 20 | 0.22" | 0.034 lb | |
| IGU-CF211-05-02-02 | 2 Pair / 4 Conductors | 20 | 0.31" | 0.054 lb | |
| IGU-CF211-05-03-02 | 3 Pair / 6 Conductors | 20 | 0.35" | 0.068 lb | |
| IGU-CF211-05-04-02 | 4 Pair / 8 Conductors | 20 | 0.37" | 0.082 lb | |
| IGU-CF211-05-05-02 | 5 Pair / 10 Conductors | 20 | 0.43" | 0.099 lb | |
| IGU-CF211-05-06-02 | 6 Pair / 12 Conductors | 20 | 0.49" | 0.126 lb | |
| IGU-CF211-05-08-02 | 8 Pair / 16 Conductors | 20 | 0.55" | 0.156 lb | |
| IGU-CF211-05-10-02 | 10 Pair / 20 Conductors | 20 | 0.63" | 0.218 lb | |
| IGU-CF211-05-14-02 | 14 Pair / 28 Conductors | 20 | 0.67" | 0.228 lb | |
| All cuts under 200 ft are non-returnable/ non-refundable | |||||
MANUALS & USER GUIDES -
RELATED ARTICLES -
- What is the Difference Between Cable Shielding and Insulation?
- The Facts on American Wire Gauge (AWG)
- 10 Easy Ways to Protect Against Electrical Hazards
- How To Prevent Soldering-Related Health Hazards
- What's the Difference Between Cat6 and Cat6a?




Facebook Comments