IDEAL’s ID-61-807 Power Quality Analyzer is built with components utilizing the most advanced technological equipment in electronics, incorporating some features and device performance enhancements only found in the highest quality power meters and harmonic analyzing devices. This equipment will provide many years of reliable performance with extremely accurate test results and data. More |
- Programmable options allow you to modify to your needs
- Backlit screen means you can see readings in dimly lit conditions
- True RMS so your readings are precise and accurate
- Safety standards EN60664 EN61010 EN61036 VDE110 UL94 CAT III600Volt as per 61010
- Integrated real time clock assures your readings are kept on accurate time
- 1MB data storage memory gives you space to keep your readings internally (up to 1 month of recording time)
- Customized data collection to suit your own requirements
- Measures: energy and harmonics, kilowatts, volt amperes, inductive reactive power, capacitive reactive power, power factor frequency, kilowatt hour
- 100A Neutral Current Clamp included
- Auto-detect clamps
- Optional FIFO memory
- Single or three-phase measurements
- True RMS
- Data logging (1 MB memory)
- Auto ranging
- Min/max/avg
- Energy and Harmonics Program
- PowerVision™ Software
- Optional programs
- Lightweight portable design
- Easy-to-use push button operation
- Password protected on-screen setup
- RS-232 interface
- 4-Channel for voltage and current measurements
- Customized data collection
- Real-time clock
- Programmable trigger-points and start/stop time
- 4 channels of voltage measurement
- 4 channels of current measurement
- Intelligent battery operated system
- Power and Energy Measurements
- Kilowatts (KW)
- Volt amperes (VA)
- Inductive Reactive Power (kvarL)
- Capacitive Reactive Power (cvarL)
- Power Factor (PF)
- Frequency
- Kilowatt Hours (KH)
- Reactive Power per Hour (kvarhL, kvarhC)
- Harmonics Measurements
- Total Harmonic Distortion (%THD)
- Harmonic Factorization (FFT) to 51st Harmonic
- 2 year warranty
The 61-807 advanced test modes will assist in identifying supply irregularities that can reduce costs and in testing to enable you to correct electrical equipment supplies and eliminate distribution system problems. It’s designed to carry out testing on a variety of electrical supply systems which include 3-phase 4-wire, 3-phase 3-wire, single-phase, split phase, and on power distribution.
Included Accessories:
- Power Quality Analyzer
- Power supply
- CD and Instructions
- Hard Carrying Case
- 4 Color coded test leads with alligator clips
- 100A Clamp Adapter
- 3 1000A AC Current Clamps
- RS-232 Interface
- Energy and Harmonics Programming Module PowerVision Analysis Software
Optional Accessories:
- 61-810 2000/200AACC POWER CLAMP ADAP FOR 61-806/61-807 (SET OF 3)
- 61-811 1000AAC POWER CLAMP ADAPTERS FOR 61-806/61-807 (SET OF 3)
- 61-812 500AAC POWER CLAMP ADAPTERS FOR 61-806/61-807 (SET OF 3)
- 61-813 100AAC PWR CLAMP ADPTR FOR 61-806/61-807 (SET OF 3)
- 61-814 5AAC POWER CLAMP ADAPTER FOR 61-806/61-807
- 61-815 DISTURBANCES PROGRAM FOR 61-806 & 61-807
| Ratings : | EN60664 EN61010 EN61036 VDE110 UL94 CAT III 600 Volt as per 61010 |
|---|---|
| Supply Voltage : | Through an external power supplier set 120 VAC (+10% / -15%) |
| Frequency : | -50 to 60 Hz |
| Burden : | -8 VA |
| Operating Temperature : | 0° - 50°C |
| Measuring Circuit : | THREE PHASE, ARON |
| Safety : | Category II - 600 V, as per EN 61010 |
| Voltage Measurement : | Measuring range: 20 to 500 V a.c. (phase-neutral) 20 to 866 V a.c. (between phases) automatic scale adjustment Other voltages: through suitable voltage transformers Frequency: 45 to 65 Hz |
| Display : | LCD; 160 x 160 pixels |
| RS-232 Output : | Serial type output |
| Internal Memory : | 256 kbytes to 1 Mb according to the model |
| Accuracy : | Voltage: 0.5 % of readout ± 2 digits Current 0.5 % of readout ± 2 digits |
| Active Power : | 1.0 % of readout ± 2 digits Reactive power 1.0 % of readout ± 2 digits |
| Accuracy Conditions : | Errors due to voltage and current transformer not included |
| Temperature Range : | 5°C to 45°C, Power factor: 0.5 to 1 |
| Measuring Range : | between 5% and 100% |
| Safety Standards : | EN 60664, EN 610110, EN 61036, VDE 110, UL 94 |
| Dimensions : | 220 x 60 x 130 mm |
| Kit Weight : | 20.5 lbs |
| PART # | DESCRIPTION | WEIGHT | PRICE |
| ID-61-807 | Power Quality Analyzer | 20.5 lbs | |
| Accessories | |||
| ID-61-810 | 200AAC Power Clamp Adapters | 13.95 lbs | |
| ID-61-811 | 1000AAC Power Clamp Adapters | 5.8 lbs | |
| ID-61-812 | 500AAC Power Clamp Adapters | 5.8 lbs | |
| ID-61-813 | 100AAC Power Clamp Adapters | 1.7 lbs | |
| ID-61-814 | 5AAC Power Clamp Adapters | 0.4 lbs | |
| ID-61-819 | 5AAC Power Clamp Adapter Set of 3 | 2.4 lbs | |
| ID-61-820 | 100AAC Power Clamp Adapter Set of 3 | 2.35 lbs | |
| ID-61-821 | 100AAC Clamp Adapter | 1.8 lbs | |
| ID-61-457 | 200/2K/20KAC Flexible Clamp | 4 lbs | |
MANUALS & USER GUIDES -
- IDEAL 800 Series Power Analyzer Instruction Manual (PDF)

- IDEAL Catalog Section E Tests and Measurement (PDF)

RELATED ARTICLES -