Technical Specifications: Heat Shrink End Caps

Back to main page

Property Test Method Values
Operating Temperature Range n/a -55C to 110C
Shrink Temperature n/a 120C
Tensile Strength ISO 37 14 Mpa minimum
Ultimate Elongation ISO 37 400% minimum
Specific Gravity ISO 1183 1.95 maximum
Electric Strength IEC 243 15KV/mm minimum
Corrosion (Copper Contact and Copper Mirror) ASTM D2671 no corrosion
Water Absorption ISO 62 0.5% maximum

  Fluid Resistance

Gasoline
Lubricating Oil
Hydraulic Fluid
Water
- Tensile Strength
- Ultimate Elongation

ISO 1817





ISO 37







8.8 MPA minimum
400% minimum

Fungus Resistance ISO 846 no fungal growth

 

 