DTX Digital Cable Analyzers & Certification Testers

High Accuracy Cable Ananlysis for Professionals

Low Price Guarantee

DFL-DTX-1200   

What's special about this cable analyzer and tester?

  • Top performance at Level IV Accuracy
  • Bright backlit display for better viewing
  • Lightweight for easy carrying
  • Allows you to communicate over copper and fiber
  • Click for More Features

Fluke DTX Series Cable Analyzers significantly reduce the time it takes to certify your network when compared with competitors' analyzers. The Fluke DTX testers will test and certify your CAT 6 cable in 12 seconds. Most other testers take over 30 seconds to perform the same test. This translates to 85 extra certifications before lunch! Not only do these analyzers test for problems, they also suggest potential actions to correct the problem, saving even more troubleshooting time.

Images

Please Note: These products ship within 2 weeks

PART # DESCRIPTION MAX TESTING BANDWIDTH PRICE
DFL-DTX-1200 Fluke DTX-1200 Cat 6 Tester 350 MHz
Qty:  
DFL-DTX-1800 Fluke DTX-1800 Cat 6 Tester 900 MHz
Qty:  

The DTX 1200 has a maximum testing bandwidth of 350 MHz, allowing all tests to be done in just 12 seconds in full compliance with industry standards.

The DTX 1800 has a maximum testing bandwidth of 900 MHz, which will allow you to test video distribution, Class F, CATV and 10 Gigabit Ethernet cables.

Unit's internal memory stores up to 250 graphical Cat 6 test results or up to 2000 text reports. In addition each unit includes LinkWare software for link to your PC. Software allows you to edit, view, print, and archive your data. You can then export the data to a PDF.

Fiber Modules also available … Please call 866-222-0030

 

Includes:

  • DTX-1200 Main and Smart Remote
  • LinkWare PC Software
  • Cat 6/Class E Permanent Link Adapters (2)
  • Cat 6/Class E Channel Adapters (2)
  • Headsets for Talk (2)
  • AC Chargers (2)
  • Carrying Case
  • USB Interface Cable (Mini-B)
  • User Manual

 

Cable Types

Standard Link
Interface Adapters
Shielded and unshielded Twisted Pair (STP, FTP, SSTP and UTP) LAN cabling:
  • TIA Category 3, 4, 5, 5E and 6: 100Ω
  • ISO/IEC Class C and D: 100Ω and 120Ω
  • ISO/ IEC Class E, 100W ISO/ IEC Class F, 100Ω
  • Cat 6/ Class E permanent link adapters Plug type and life: shielded and unshielded cable, TIA Cat 3, 4, 5, 5e, and 6 and ISO/IEC Class C, D and E permanent link
  • Cat 6/Class E channel adapters Plug type and life: shielded and unshielded cable, TIA Cat 3, 4, 5, 5e, and 6 and ISO/IEC Class C, D and E channels
Test Standards
  • TIA Category 3 and 5e per TIA/EIA-568B
  • TIA Category 5 (1000BASE-T) per TIA TSB-95
  • TIA Category 6 per TIA/EIA-568B.2-1 (Addendum #1 to TIA/EIA-568B.2)
  • ISO/IEC 11801 Class C, D, and E
  • ISO/IEC 11801 Class F (DTX-1800 only)
  • EN 50173 Class C, D, E
  • EN 50173 Class F (DTX-1800 only)
  • ANSI TP-PMD
  • IEEE 802.3 10BASE-T, 100BASE-TX, 1000BASE-T
  • IEEE 802.5 (STP cabling, IBM Type 1, 150Ω ) Token Ring, 4 Mbps and 16 Mbps
Speed of Autotest Full 2-way Autotest of Category 6 Twisted-Pair links in 12 seconds or less
Full 2-way Autotest of ISO/IEC Class F links in 32 seconds
Supported Tests Parameters (The selected test standard determines the test parameters and the frequency range of the tests)

Wire Map
Length
Propagation Delay
Delay Skew
DC Loop Resistance
Insertion Loss (Attenuation)
Return Loss (RL), RL @ Remote
NEXT, NEXT @ Remote
Attenuation-to-crosstalk Ratio (ACR), ACR @ Remote
ELFEXT, ELFEXT @ Remote
Power Sum ELFEXT, PSELFEXT @ Remote
Power Sum NEXT, PSNEXT @ Remote
Power Sum ACR, PSACR @ Remote
Cable Tone Generator Generates tones that can be detected by a tone probe such as a Fluke Networks IntelliTone probe. The tones are generated on all pairs. Frequency range on all pairs. Frequency range of tones: 440 Hz to 831 Hz
Display 3.7 in (9.4 cm) diagonal, 240 dots wide by 320 dots high, passive color, transmissive LCD with backlight.
Input Protection Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage.
Case High impact plastic with shock absorbing over-mold
Dimensions Main unit and Smart Remote: 8.5 in x 4.4 in x 2.4 in (21.6 cm x 11.2 cm x 6cm), nominal
Weight 2.4 lb (1.1 kg), nominal (without adapter or module)
Operating Temperature 32°F to 104°F (0°C to 40°C)
Storage Temperature -4°F to +140°F (-20°C to +60°C)
Operating relative humidity (% RH without condensation) 32°F to 95 °F (0°C to 35°C): 0 % to 90 % 95°F to 113°F (35°C to 45°C): 0 % to 70 %
Vibration Random, 2 g, 5 Hz -500 Hz
Shock 1 m drop test with and without module and adapter attached
Safety CSA C22.2 No. 1010.1: 1992 EN 61010-1 1st Edition + Amendments 1, 2
Pollution degree Pollution Degree 2 as defined in IEC 60664 and applied to IEC 60950 "Safety of Information Technology Equipment, 1999"
Altitude Operating: 4000 m; Storage: 12000 m
EMC EN 61326-1
Power

Main unit and remote: Lithium-ion battery pack, 7.4 V, 4000 mAh

  • Typical battery life: 12 to 14 hours
  • Charge time (with tester off): 4 hours (below 40 °C)
  • AC adapter/charger, USA version: Linear power supply; Input 108 V ac to 132 V ac, 60 Hz ; Output 15 V dc, 1.2 A
  • AC adapter/charger, international version: Switching power supply; Input 90 V ac to 264 V ac, 48 to 62 Hz; Output 15 V dc, 1.2 A (isolated output)
  • Memory backup power in main unit: Lithium battery
  • Typical life of lithium battery: 5 years
    The battery will not charge at temperatures outside of 0°C to 45°C (32°F to 113°F). The battery charges at a reduced rate between 40°C and 45°C (104°F and 113°F).
Calibration Service center calibration period is 1 year
Performance Specifications Note: all specifications for tests on twisted-pair cabling apply to 100 Ω cable. Contact Fluke Networks for information on measurement performance for cable with a different impedance.
Baseline accuracy The baseline accuracy of all DTX Series testers meets or exceeds the requirements of Level IV as in draft 2nd Edition of IEC 61935-1 over the frequency range supported by the tester.
Category 6/Class E link test modes (and lower link categories) DTX CableAnalyzer far exceeds Level III requirements of TIA/EIA-568-B.2-2 and IEC 61935-1
Class F link test modes DTX-1800 is compliant with Level IV requirements as in the draft 2nd edition of IEC 61935-1.
Length for Twisted Pair Cabling (Length specs do not include the uncertainty of the cable's NVP Value)
Parameter Single-ended Test
Dual-ended Test (Main and Remote)
Range 800 m (2600 ft) - Single-ended Test
150 m (490 ft) - Dual-ended Test (Main and Remote)
Resolution 0.1 m or 1 ft - Single-ended Test
0.1 m or 1 ft - Dual-ended Test (Main and Remote)
Accuracy ± (1m + 4%) - Single-ended Test
± (1m + 4%) - Dual-ended Test (Main and Remote)
Delay Skew
Parameter Twisted Pair Cabling
Range 0 ns to 100 ns
Resolution 1ns
Accuracy ± 10 ns
DC Loop Resistance Test
Parameter Twisted Pair Cabling
Range O Ω to 53Ω
Resolution 0.1 Ω
Accuracy ± (1 Ω+ 1%)
Overload Recovery Time Less than 10 minutes to rated accuracy following over-voltage. Referencing is required after repeated or prolonged over-voltage.

MANUALS & USER GUIDES -



RELATED ARTICLES -

 



HOW-TO CORNER -

 

VIEW OUR GLOSSARY

 

Fluke Digital MultimeterFluke Digital Multimeter
From
More accurate measurements of voltage and current. With unique features such as a built in thermometer, Auto ranging and manual ranging for increase flexibility, an analog bar graph for unstable signals, and a lifetime warranty.

LAN testerOther Multimeters/ Test Equipment
 

cable fault findersFluke TS® Cable Fault Finders
From
Designed to quickly locate cable faults or just measure the length of a cable run, these testing units are perfect for the fast, easy analysis and troubleshooting of Cat and coax cable.

Fluke CableIQFluke CableIQ™ Qualification Tester
From
Do you need to determine whether your existing cabling setup supports your 1000 BASE-T (Gigabit) network? A qualification tester is all you need. Basically, if you're looking to differentiate between cabling problems and network problems, a qualification tester is all you need.

Q:

is there anyway to change in entry into the database after stored testing result without having to delete the item in the database and you do a new entry Friend Stream changing a room number in a story database entry in the folder?

Asked by Anonymous user on

Do you have any question about this product?
Let our experts and customers resolve all your doubts

Did you know that we can give you a quote for most of our products, including shipping?


You can also call us toll free 866.222.0030

REVIEW SNAPSHOT®

by PowerReviews
Fluke DTX 1200 Cat 6 Cable Tester
 
4.0

(based on 1 review)

Ratings Distribution

  • 5 Stars

     

    (0)

  • 4 Stars

     

    (1)

  • 3 Stars

     

    (0)

  • 2 Stars

     

    (0)

  • 1 Stars

     

    (0)

Reviewed by 1 customer

Displaying review 1

Back to top

(2 of 5 customers found this review helpful)

 
4.0

Very good

By Peter Lincol

from Miami. Florida

About Me High bandwidth user

Pros

  • Easily Expanded
  • Highly Compatible
  • Secure

Cons

  • Bulky

Best Uses

  • Highly Secure Networks
  • High Volume

Comments about Fluke DTX 1200 Cat 6 Cable Tester:

From very useful in corporate networks. for a rapid diagnosis and reliable. Highly recommended.

  • Primary use:
  • Business

Displaying review 1