Fluke Networks TS®100 and TS®90 Cable Fault Finders

Measure and Identify Cable Length

Fluke cable fault finders, 26500000, 26500090

Close Window

Fluke Networks TS®100 and TS®90 Cable Fault Finders

    Additional Images
  • Fluke Networks TS Cable Fault Finders - icon
  • Fluke TS90 Cable Fault Finder - icon
  • Fluke TS100 Cable Fault Finder with line cord - icon
  • Fluke TS100 Cable Fault Finder with line cord - icon
  • Line Cord with BNC to banana clips - icon
  • Line Cord with BNC to f male - icon

This requires one or more of the following: javascript enabled, Flash Video Player, and Quicktime or Windows Media Player
Copyright ©2014 CableOrganizer.com

CE  UL and CSA

Low Price GuaranteeWhat's special about these cable fault locators?

  • Allows you measure the distance to a cable fault, and helps to easily identify the source of cable connectivity problems
  • Quick and easy one-button operation gives accurate results up to 2500 ft (TS®90) to 3000 ft (TS®100)
  • Equipped with SmartTone™ technology to work as a tone generator and assist in identifying pairs
  • Click for More Features

Fluke’s TS®90 and TS®100 Cable Fault Locators are ideal for quick and easy cable analysis on the spot. The simple to use design gives fast results without any complicated wording or additional buttons to press.

  • Allows you to test other types of cabling, including coax, with the F-Connector line cord
  • Provides the ability to measure the amount of cable on a spool or in a cable run before installation, so you can be fully equipped on the jobsite
  • Large LED screen displays results in an easy to read numerical format instead of TDR, which can be difficult to read
  • Results are given instantly and continuously once the tester is turned on to help find intermittent faults
  • Also works well for high voltage detection, so you can test a cable before working on it
  • Saves time on installation and repair, since you can now “see” the area where a cable has a fault instead of cutting into walls or running all new cable
  • Moisture-proof, so unit will still operate in damp conditions
  • Can also be used as a tool to assist in checking cable inventory in your truck or warehouse

 

  TS90 TS100
Price
Qty:  
Qty:  
Part # FL-26500090 FL-26500000
Power of operation 4 AA alkaline batteries provide 50 hours of operation 4 AA alkaline batteries provide 50 hours of operation
Reverse Battery Protection No damage to the tester will occur if the batteries are installed backward No damage to the tester will occur if the batteries are installed backward
Input Protection 250 V RMS AC, continuous or intermittent 250 V RMS AC, continuous or intermittent
Moisture If the tester is exposed to water, some may get inside, but it will suffer NO DAMAGE. See the moisture notes in the Maintenance section. If the tester is exposed to water, some may get inside, but it will suffer NO DAMAGE. See the information on moisture under “Maintenance”.
Impedance Range 35 Ω to 330 Ω with auto-compensation within this range. Cables with an impedance outside this range will not be properly tested and may produce erratic or incorrect readings. 35 Ω to 330 Ω with auto-compensation within this range. Cables with an impedance outside this range will not be properly tested and may produce erratic or incorrect readings.
Maximum Length 2500 feet on most cable types, and 500 feet on very lossy cables. The tester will display -ERR if the cable is too long to be correctly measured 2500 feet on certain cable types, 2000 feet on most cable types, and 500 feet on very lossy cables. The tester will display –ERR if the cable is too long to be correctly measured
Representative Maximum 2500 feet [770 m]: CAT5 Twisted Pair 3000 feet [770 m]: CAT5 Twisted Pair
Cable Length 2000 feet [610m]: 12/2 AC Wire 2000 feet [610m]: 12/2 AC Wire
1000 feet [300 m]: RG-6/U TV Coax 1000 feet [300 m]: RG-6/U TV Coax
500 feet [150 m]: RG-174/U Coax 500 feet [150 m]: RG-174/U Coax
Minimum Length No minimum length; minimum non-zero reading is 2 feet No minimum length; minimum non-zero reading is 2 feet
Length Accuracy ±2 feet for cables less than 10 feet; ±5 feet for cables longer than 10 feet and shorter than 200 feet; ±3% and ±5 feet for cables longer than 200 feet ±2 feet for cables less than 10 feet; ±5 feet for cables longer than 10 feet and shorter than 200 feet; ±3% and ±5 feet for cables longer than 200 feet
High Voltage Detection An AC voltage of more than 5 V RMS will trigger the High Voltage Warning. An AC voltage of more than 5 V RMS will trigger the High Voltage Warning.
Measurement Rate Maximum of 4 complete measurements per second, decreasing to 2 seconds per measurement based on cable size and uniformity. Maximum of 4 complete measurements per second, decreasing to 2 seconds per measurement based on cable size and uniformity.
VOP Adjustable from -20- to -99-, retained during power off. Default to -66- when batteries are changed. Adjustable from -20- to -99-, retained during power off. Default to -66- when batteries are changed
Measurement Technology Time Domain Reflectometry (TDR) with 50 Ω drive impedance, 6 V maximum pulse height. Time Domain Reflectometry (TDR) with 50 Ω drive impedance, 6 V maximum pulse height
Low Battery Indicator flashes when battery voltagefalls below 4.1 V Indicator flashes when battery voltage falls below 4.1 V
Tone Injection Approximately 1 kHz at an amplitude of 80% of battery voltage. Variable frequency and cadence. Tone characteristic is changed as cable condition changes to “normal-open” from any other condition. Approximately 1 kHz at an amplitude of 80% of battery voltage. Variable frequency and cadence. Tone characteristic is changed as cable condition changes to “normal-open” from any other condition.
Cable Type Virtually all two or more conductor cables Virtually all two or more conductor cables
Temperature
Operating 32° F to 131° F (0° C to 55° C) 32° F to 131° F (0° C to 55° C)
Storage  -40° F to 158° F (-40° C to 70° C)  -40° F to 158° F (-40° C to 70° C)
Humidity
Operating 0% to 80% 0% to 80%
Storage 0% to 100% 0% to 100%
Weight 1 lb with batteries and clip leads 1 lb
Dimensions 7.4"H x 2.75"W x 1.5"D 7.4"H x 2.75"W x 1.5"D
Operating Altitude 10,000 ft max 10,000 ft max
Certifications and Compliance Conformité Européenne. Conforms to relevant European Union directives. CAN/CSA-C22.2 No. 60950-1-03 CAN/CSA-C22.2 No. 1010.1-92 CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1 Conformité Européenne. Conforms to relevant European Union directives. CAN/CSA-C22.2 No. 60950-1-03 CAN/CSA-C22.2 No. 1010.1-92 CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1

 

Patent Number(s): 6160405, 6285195, 6323654, 6509740

 

PART # DESCRIPTION RANGE PRICE
FL-26500090 TS90 Cable Fault Finder w/ BNC to alligator clips 2500 ft CAT5 (max)
Qty:  
FL-26500000 TS100 Cable Fault Finder w/ BNC to alligator clips 3000 ft CAT5 (max)
Qty:  
FL-26500390 TS100 with long linecord, ABN/PP clip (general) 3000 ft CAT5 (max)
Qty:  
FL-26500500 TS100 with BNC to banana to ABN 3000 ft CAT5 (max)
Qty:  
FL-26500610 TS100 Metric Cable Fault Finder with BNC to alligator clips 3000 ft CAT5 (max)
Qty:  

 

Accessories

PART # DESCRIPTION PRICE
FL-26501160 TS100/TS90 pouch with belt clip
Qty:  
FL-26501200 TS100/TS90 line cord, BNC to F(MALE)
Qty:  
FL-26501600 TS100/TS90 line cord, banana
Qty:  

REVIEW SNAPSHOT®

by PowerReviews
TS90 cable fault finder with BNC to alligator clips(testing up to 2500ft)
 
4.0

(based on 1 review)

Ratings Distribution

  • 5 Stars

     

    (0)

  • 4 Stars

     

    (1)

  • 3 Stars

     

    (0)

  • 2 Stars

     

    (0)

  • 1 Stars

     

    (0)

Reviewed by 1 customer

Displaying review 1

Back to top

 
4.0

I've bought one, then two more.

By Bob

from Middleburg, FL

Verified Buyer

Pros

  • Good for cable on reels
  • Small

Cons

    Best Uses

    • Measuring cable lenghts

    Comments about TS90 cable fault finder with BNC to alligator clips(testing up to 2500ft):

    I intend to buy more as the company grows.

    Displaying review 1

    Back to top

    JackRapid Punchdown ToolFluke JackRapid Punch Down Tool
    From
    JackRapid allows you to terminate jacks eight times faster than traditional impact tools - with accuracy that's unmatched. The patented jack termination tool seats and terminates all wires simultaneously. With JackRapid, you’ll never punch into the palm of your hand or through drywall again.
    cable fault finderTDR Cable Fault Finder
    Price
    This TDR is a hand-held Digital Cable Length Meter / TDR Fault Locator designed to both measure the length of copper communication cables and distance to a fault. Advanced signal processing techniques enable it to identify opens and short circuits, and directly indicate the fault distance on an alpha-numeric LCD.
     
    Fluke CableIQFluke CableIQ™ Qualification Tester
    From
    Do you need to determine whether your existing cabling setup supports your 1000 BASE-T (Gigabit) network? A qualification tester is all you need. Basically, if you're looking to differentiate between cabling problems and network problems, a qualification tester is all you need.
    Fluke Digital MultimeterFluke Digital Multimeter
    From
    More accurate measurements of voltage and current. With unique features such as a built in thermometer, Auto ranging and manual ranging for increase flexibility, an analog bar graph for unstable signals, and a lifetime warranty.
     
    wire markersWire Markers, Labels
    From
    Variety of ways to help you get those wires and cables identified.
     

    What can make this page better?

    We do everything we can think of to provide you with the product specs, images and ordering info you need, but if were missing something or still have room to improve, please let us know. Your comments, suggestions and questions are the best tools we have for serving you better!