Lake Effect Enclosures from Great Lakes
The Ultimate Cooling Enclosure - No Refrigerants, Liquids, or Modifications Required
Close Window
Lake Effect Enclosures from Great Lakes
This requires one or more of the following: javascript enabled, Flash Video Player, and Quicktime or Windows Media Player
|
|
- No infrastructure changes to install
- No water or refrigerants or any other liquid introduced into data center environment
- No additional piping, duct work or floor modifications necessary
- Will not invade under floor of cabinet
- Does not infringe on existing raised floor pressure
- Vanaxial fans

- Directional airflow of up to 1224 CFM to the intake of the servers
- Environmental monitoring available
- Wide range of PDU’s available
- Intake Ambient Air: 65° F
Enhancing Features :
- Local and remote monitoring
- Remote re-boot control
- Single or Dual Power Feed
- Digital Display
- User-Friendly Software
- Made in the

Thermal patented technology makes the Great Lakes Lake Effect Enclosure your solution for all your networking needs. This Enclosure eliminates the use of refrigerants or coolants in your data center environment. The use of vanaxial fans originally designed for the aerospace industry allows this enclosure to create a usable air environment which can satisfy up to a 10KW of computer load. A consistent 65 degree temperature in the front plenum chamber is maintained from top to bottom, there by protecting your equipment from hardware failure due to overheating. It contains a 44 RMU rack space, and all the same features as our Great Lakes Enhanced Series Enclosures.
This product has starred in our Product Showcase Blog! Click here to check it out.
- Dimensions: 84”H x 30”W x 48”D
- Rack Spaces: 44 RMU without fan box (37 RMU with fan box), 19” EIA 310-D Compliant
- Weight Capacity: 2,000 lbs. on levelers, bolted to floor, or on casters
- Shipping Weight: 575 lbs.
- Colors: Black
- Made of 14-16 gauge cold rolled steel
| PART # Click below to view images |
DESCRIPTION | SIZE | PRICE |
Custom Enclosure |
|||
| QGL-8401LE-3048 | Lake Effect Base Unit with two (2) pair of powder coated 19” universal M6 rails and M6 hardware, shipping pallet, and two (2) sets of power strip brackets | 84"H x 30"W x 48"D | |
| QGL-8402-LE | Plexi door with lower bottom mesh- front | for 84"H x 29"W Base Unit | |
| QGL-8402E-M29 | Mesh steel door with locking swing handle - rear | for 84"H x 29"W Base Unit | |
| QGL-8410-36ELS | Pair Locking Lift-off Solid Side Panels |
84"H x 36"D | |
| QGL-TPE-29P | Perforated Top Panel w/Two 4" Horseshoe Knock-outs | - | |
| QGL-LE-CM | Vertical cable management tray (2) | - | |
| QGL-LE-FB | Fan Box Kit, Patented Our patented technology achieves a positive air pressure environment, created by a 7 RMU fan box, 3 sided adjustable depth plenum both sealed to the front door. The servers/filler panels form the rear surface which yields a consistent temperature curtain at the front of the cabinet providing an environment that is the right temperature, the right air quality, delivering to the face of every computer in the cabinet. |
- | |
| QGL-LE-PL | Plenum kit, Patented | - | |
| Enclosure Kits (includes all the items above) | |||
| QGL-GL840LE-3048 | Lake Effect enclosure kit complete floor mount | 84"H x 30"W x 48"D | |
| QGL-GL840LE-3048-LG | Lake Effect enclosure kit complete with leveling glides | 84"H x 30"W x 48"D | |
| QGL-GL840LE-3048-LGC | Lake Effect enclosure kit complete with casters and levelers | 84"H x 30"W x 48"D | |
| Cabinet without Fan Box Kit and Plenum Kit | |||
| QGL-GL840LE-3048-MC | Lake Effect enclosure mesh contour front and rear doors without Fan Box and Plenum Kit | 84"H x 30"W x 48"D | |
| QGL-GL840LE-3048-MC-LG | Lake Effect enclosure with mesh contour front and rear doors without Fan Box and Plenum Kit (includes leveling glides) | 84"H x 30"W x 48"D | |
| QGL-GL840LE-MC-LGC | Lake Effect enclosure with mesh contour front and rear doors without Fan Box and Plenum Kit (includes leveling glides and casters) | 84"H x 30"W x 48"D | |
| GE-LIFT | *** If your delivery will require a LIFT GATE you must select this option. *** CableOrganizer.com, Inc reserves the right to bill for those actual charges incurred from the shipping companies for services not identified by the customer. These 'additional services/charges' include the following: A lift gate, inside delivery & storage. |
||
| PART # Click below to view item |
DESCRIPTION | SIZE | PRICE |
| Accessories | |||
| DOORS | |||
| QGL-8404E-M29 | Bevel mesh door (accepts 7217LE3 door fans) | for 84"H x 29"W Base Unit | |
| QGL-8404E-MC24 | Mesh Contour Steel Door | - | |
| QGL-8402E-29SM | Split mesh door | for 84"H x 29"W Base Unit | |
| QGL-8404E-29 | Plexiglas door with locking swing handle | for 84"H x 29"W Base Unit | |
| SIDE PANELS | |||
| QGL-8411-36ELL | Pair locking lift-off louvered side panels | for 84"H x 36"D Base Unit | |
| REMOVABLE TOP & BOTTOM PANELS | |||
| QGL-TPES-S | Solid Top Panel for ES & LE Racks | for 29"W Base Unit | |
| QGL-TPES-P | Perforated Top Panel for ES & LE Racks | for 29"W Base Unit | |
| QGL-TPES-F | Top Panel with Fan Assembly for ES & LE Racks | for 29"W Base Unit | |
| QGL-TPES-F10 | 550 CFM 10" Fan Top Panel for ES & LE Racks | for 29"W Base Unit | |
| QGL-TPES-2F10 | 2 x 550 CFM 10" Fan Top Panel for ES & LE Racks | for 29"W Base Unit | |
| CABLE MANAGEMENT | |||
| QGL-LE-CM | Vertical cable management tray (rear) | - | |
| QGL-HCM-W29ES | Waterfall cable management | - | |
| QGL-VLB-8436 | Vertical lacing bar kit (includes 1 vertical lacing bar, 2 horizontal lacing bars and 6 CM-01 cinch straps) | for 84”H x 36”D enclosures | |
| FILLER/BLANKING PANELS | |||
| QGL-875-FP19 | 8.75”H, 19” Rack Mounting | 5 RMU | |
| QGL-1400-FP19 | 9 14.00”H, 19” Rack Mounting | 8 RMU | |
| POWER OUTLET STRIPS, COPPER BUS BARS & COOLING EQUIPMENT | |||
| QGL-7215 View Specifications |
49" 16 Position Power Strip w/ Circuit Breaker, 5-15P plug, 5-15R Receptacle (16 outlets) | 49" Length | |
| QGL-7215-S View Specifications |
6 position power strip with circuit breaker (19" rack mounted) | 49" Length | |
| QGL-7215-20AR View Specifications |
49" 16 Position Power Strip w/ Circuit Breaker, 5-20P plug, 5-20R Receptacle (16 outlets) | 49" Length | |
| QGL-7215-30A View Specifications |
16 position power strip w/circuit breaker & 5-20P plug | 48" Length | |
| DOOR HANDLES | |||
| QGL-CH-01 | Four digit combination handle | - | |
| QGL-CH-02 | Three digit combination handle | - | |
| QGL-CH-03 | Pad lock handle with key | - | |
| QGL-CH-04 | Pad lock handle | - | |
| COOLING DEVICES | |||
| QGL-7217FT | Fan tray with three 75 CFM fans | - | |
| QGL-7217FT-3 | Front & rear mount, adjustable fan tray w/ three 75 CFM fans | - | |
| QGL-7217FT-6 | Front & rear mount, adjustable fan tray w/ six 75 CFM fans | - | |
| QGL-7217FT-9 | Front & rear mount, adjustable fan tray w/ nine 75 CFM fans | - | |
| QGL-7217-LE1 | Fan Assembly w/ fan adaptation plate (installs in rear top) | - | |
| QGL-FTBKT90 | Fan Bracket to mount the 7217-FT fan at a 90 degree angle | - | |
| QGL-FTC101 | Fan Thermostat Controller Thermostat controlled 15 amp duplex outlets, UL listed, CSA certified thermostat, 50° to 90°F / 10° to 30°C temperature range, 6 ft. cord |
- | |
| QGL-7217LE3 | Fan kit w/three 75 CFM fans (door fan for use with 8404E-M29) | - | |
| MISC. ACCESSESSORIES | |||
| QGL-LE-DP | Divider panels (separates power from data) | - | |
| QGL-LE-BKT | Top Bonnet (accepts remote display) | - | |
| QGL-HDW-105-25 | Package of 25 M6 Cage Nuts with Screws 1.7 to 2.7mm Cage Nut / 12mm Screw | - | |
| QGL-HDW-105-50 | Package of 50 M6 Nuts with Screws 1.7 to 2.7mm Cage Nut / 12mm Screw | - | |
This product has starred in our Product Showcase Blog! Click here to check it out.
MANUALS -
RELATED ARTICLES -
- Seismic Enclosures
- 10 Tips for Rack System Installation
- 5 Things to Consider When Purchasing a Rack System
- What I Need to Know About Racks
- Integrating Electronic Equipment and Power Into Rack Enclosures
- Optimize Your Space with the Great Lakes WE Server Side Wall Mount
- Cooling Off with Thermal Enclosures
- How to Prevent EPO Button Mishaps in Your Data Center
HOW-TO CORNER -



Facebook Comments