CCT® Category 5e UTP Ethernet Cable

Quality Made, Affordable Networking Cables

Low Price Guarantee

CCT-CAT5EP4   

What's special about these data cables?

  • Meets or exceeds ANSI/TIA/EIA, UL, and ETL standards for highly efficient Cat5e performance and quality construction
  • Choice of blue or white jacket color for easy identification of different cable runs
  • Available in several jacket types and conductor gauges to suit your application, including plenum, riser, flame retardant and gel-filled for outdoors
  • Click for More Features
RoHS CompliantULETL Listed

Category 5e cables by CCT® are made with top quality copper and insulative materials to insure high performance in your networking application. All cables meet or exceed ANSI/TIA/EIA standards for efficient data transfer, and most are made in the USA for use in GSA applications.

CCT Cables

Images

Part # DESCRIPTION JACKET PAIR/AWG QUANTITY COLORS PRICE / 1000 FT
Plenum
CCT-CAT5EP4 Unshielded Plenum Flame Retardant PVC 4/24 1000 ft (308m) Black
Qty:  
CCT-CAT5ESP4 Shielded Plenum 4/23
Qty:  
Riser
CCT-CAT5ENP4 Unshielded Enhanced Riser PVC 4/24 1000 ft (308m) Black
Qty:  
CCT-CAT5ENP4AM Unshielded Enhanced Riser (Made in USA) 4/24
Qty:  
CCT-CAT5ENP25 Unshielded 25-Pair Enhanced Riser 25/24
Qty:  
Outdoor and CM
CCT-CAT5ENP4DBF Gel-filled Enhanced (Outdoor) Polyethylene 4/24 1000 ft (308m) Black
Qty:  
CCT-CAT5ESNP4 Shielded CM PVC 4/24
Qty:  

  • Several Configurations to fit your particular application:
    • CCT-CAT5ENP (CMR):
      Unshielded, twisted 4-pair Cat5e with 24 AWG conductors and PVC Jacket. Rated UL 1666 for Riser applications
    • CCT-CAT5ENP4AM (CMR):
      Unshielded twisted 4-pair Enhanced Cat5e with 24AWG conductors and PVC Jacket. Rated UL 1666 for Riser applications made in usa
    • CCT-CAT5ENP4DBF (Outdoor):
      Unshielded, twisted 4-pair Cat5e with high heat 140°F (60°C) polyethylene jacket. Flooded with water-blocking gel for outdoor installation (Not RoHS Compliant)
    • CCT-CAT5ENP25 (CMR):
      Unshielded, twisted 25-pair Cat5e with 24 AWG conductors and PVC jacket. Rated UL 1666 for Riser applications
    • CCT-CAT5ENP4 (CMP):
      Unshielded twisted 4-pair Enhanced Cat5e with 24AWG conductors and flame retardant PVC Jacket. UL 910 Rated for installation in Plenum spaces
    • CCT-CAT5ESNP4:
      Shielded, twisted 4-pair Cat5e with 24 AWG conductors and PVC jacket. Aluminum/Polyester shield with tin/copper drain. UL 1581 Rated for use in CM applications
    • CCT-CAT5ESP4 (CMP):
      Shielded, twisted 4-pair Cat5e with 23 AWG conductors and flame retardant PVC jacket. Aluminum/Polyester shield with tin/copper drain.UL 910 Rated for installation in Plenum spaces
  • RoHS Compliant for safe use in any facility with little outgassing

 

PLENUM
  CCT-CAT5EP4 CCT-CAT5ESP4
Conductors 24 AWG Solid Bare Copper 23 AWG Solid Bare Copper
Number of Pairs 4 Pair 4 Pair
Inner Jacket Material Polyvinyl Chloride Flame Retardant Polyvinyl Chloride
Shield n/a Aluminum/Polyester Tape
Drain n/a Solid Tin Copper
Outer Jacket Material Polyvinyl Chloride Flame Retardant Polyvinyl Chloride
Nominal Overall Cable Diameter 0.255 inch (6.477 mm) 0.245 inch (6.223 mm)
Approximate Cable Weight 33 lb/1,000 ft. 39 lb/1,000 ft.
Temperature Rating Installation: 0°C to 50°C
Operation: -10°C to 60°C
Installation: 0°C to 50°C
Operation: -10°C to 60°C
Velocity of Propagation 70% 70%
Mutual Capacitance 14 pF/ft Nominal 14 pF/ft Nominal
Capacitance Unbalance 330 pF/ft Maximum 330 pF/ft maximum
Maximum Conductor D.C.R. 28.6Ω/1,000 ft. 28.6Ω/1,000 ft.
Maximum D.C.R. Unbalance 5% 5%
Maximum Delay Skew 45.0ns/100m 45.0ns/100m
Maximum Propagation Delay Skew 5.7ns/100m 5.7ns/100m
Characteristic Impedance 0.772 MHz to 100 MHz 100 ± 15%
101 MHz to 250 MHz 100 ± 22%
0.772 MHz to 100 MHz 100 ± 15%
101 MHz to 250 MHz 100 ± 22%
From 201 MHz to 350 MHz
Maximum Installing Tension 25 lb 25 lb
Minimum Bending Radius 1.0 inch 1.0 inch
Standards ANSI/TIA/EIA 568C.2ISO/IEC 11801
NEC Article 800
UL 910
ETL Verified
cETLus CMP
RoHS Compliant
ANSI/TIA/EIA 568C.2ISO/IEC 11801
NEC Article 800 UL 910: CMP FT6
ETL Verified
cETLus CMP
RoHS Compliant

 

 

RISER
CCT-CAT5ENP4 CCT-CAT5ENP4AM CCT-CAT5ENP25
Conductors 24 AWG Solid Bare Copper 24 AWG Solid Bare Copper 24 AWG Solid Bare Copper
Number of Pairs 4 Pair 4 Pair 25 Pair
Inner Jacket Material Polyvinyl Chloride Polyvinyl Chloride Polyvinyl Chloride
Shield n/a n/a Aluminum/Polyester Tape
Drain n/a n/a Solid Tin Copper
Outer Jacket Material Polyvinyl Chloride Polyvinyl Chloride Polyvinyl Chloride
Nominal Overall Cable Diameter 0.185 inch (4.699 mm) 0.185 inch (4.699 mm) 0.500 inch (17.700 mm)
Approximate Cable Weight 20 lb/1,000 ft. 20 lb/1,000 ft. 106 lb/1,000 ft.
Temperature Rating Installation: 0°C to 50°C
Operation: -10°C to 60°C
Installation: 0°C to 50°C
Operation: -10°C to 60°C
Installation: 0°C to 50°C
Operation: -10°C to 60°C
Velocity of Propagation 70% 70% 70%
Mutual Capacitance 14 pF/ft Nominal 14 pF/ft Nominal 14 pF/ft Nominal
Capacitance Unbalance 330 pF/ft maximum 330 pF/ft maximum 330 pF/ft maximum
Maximum Conductor D.C.R. 28.6Ω/1,000 ft 28.6Ω/1,000 ft 28.6Ω/1,000 ft
Maximum D.C.R. Unbalance 5% 5% 5%
Maximum Delay Skew 45.0ns/100m 45.0ns/100m 45.0ns/100m
Maximum Propagation Delay Skew 5.7ns/100m 5.7ns/100m 5.7ns/100m
Characteristic Impedance 0.772 MHz to 100 MHz 100 ± 15%
101 MHz to 250 MHz 100 ± 22%
From 201 MHz to 350 MHz
0.772 MHz to 100 MHz 100 ± 15%
101 MHz to 250 MHz 100 ± 22%
From 201 MHz to 350 MHz
0.772 MHz to 100 MHz 100 ± 15%
101 MHz to 250 MHz 100 ± 22%
From 201 MHz to 350 MHz
Maximum Installing Tension 25 lb 25 lb 25 lb
Minimum Bending Radius 1.0 inch 1.0 inch 1.0 inch
Standards ANSI/TIA/EIA 568B.2.1
ISO/EIC 11801
NEC Article 800
UL 1666: CMR Riser
ETL Verified
568B.2.1
C(ETL)US CMR
RoHS Compliant
ANSI/TIA/EIA 568B.2.1
ISO/EIC 11801
NEC Article 800
UL 1666: CMR Riser
ETL Verified
cETLus CMR
RoHS Compliant
ANSI/TIA/EIA 568B.2.1
ISO/EIC 11801
NEC Article 800
UL 1666
ETL Verified
cETLus CMR
RoHS Compliant

 

 

OUTDOOR & CM
  CCT-CAT5ESNP4 CCT-CAT5ENP4DBF
Conductors 24 AWG Solid Bare Copper 24 AWG Solid Bare Copper
Number of Pairs 4 Pair 4 Pair
Inner Jacket Material Polyvinyl Chloride Polyvinyl Chloride
Shield Aluminum/Polyester Tape n/a
Drain Solid Tin Copper n/a
Outer Jacket Material Polyvinyl Chloride Polyvinyl Chloride
Nominal Overall Cable Diameter 0.255 inch (6.477 mm) 0.185 inch (4.699 mm)
Approximate Cable Weight 33 lb/1,000 ft. 20 lb/1,000 ft.
Temperature Rating Installation: 0°C to 50°C
Operation: -10°C to 60°C
Installation: 0°C to 50°C
Operation: -10°C to 60°C
Velocity of Propagation 70% 70%
Mutual Capacitance 14 pF/ft Nominal 14 pF/ft Nominal
Capacitance Unbalance 330 pF/ft maximum 330 pF/ft maximum
Maximum Conductor D.C.R. 28.6Ω/1,000 ft. 28.6Ω/1,000 ft.
Maximum D.C.R. Unbalance 5% 5%
Maximum Delay Skew 45.0ns/100m 45.0ns/100m
Maximum Propagation Delay Skew 5.7ns/100m 5.7ns/100m
Characteristic Impedance 0.772 MHz to 100 MHz 100 ± 15%
101 MHz to 250 MHz 100 ± 22%
From 201 MHz to 350 MHz
0.772 MHz to 100 MHz 100 ± 15%
101 MHz to 250 MHz 100 ± 22%
From 201 MHz to 350 MHz
Maximum Installing Tension 25 lb 25 lb
Minimum Bending Radius 1.0 inch 1.0 inch
Standards ANSI/TIA/EIA 568C.2
ISO/EIC 11801
NEC Article 800
UL 1581: CM
ETL Verified
cETLus CM
RoHS Compliant
ANSI/TIA/EIA 568B.2.1

PLENUM SPECS -

 

RISER SPECS -

 

OUTDOOR & CM SPECS -



RELATED ARTICLES -

 

VIEW OUR GLOSSARY

 

Do you have any question about this product?
Let our experts and customers resolve all your doubts

Did you know that we can give you a quote for most of our products, including shipping?


You can also call us toll free 866.222.0030

What can make this page better?