Home Networking Patch Cables, Modular Plugs, Boots Structured Cabling CAT5e/6 Network Cables
Bulk CAT 5e, CAT6 and CAT 6a Network Cable
Premium Quality Ethernet Cable for Voice and Data Communications
![]()
Close Window
Bulk CAT 5e, CAT6 and CAT 6a Network Cable
This requires one or more of the following: javascript enabled, Flash Video Player, and Quicktime or Windows Media Player |
Wiring a new/old construction for data capabilities, or connecting multiple servers to patch panels can be rather costly when doing it one cable at time. To help save installers both time and money, we now offer a wide range of affordable Cat5e and Cat6 networking cable in bulk sizes that accommodate any budget or job size. These high quality, 4-pair UTP networking cables are certified to meet and exceed today’s standards, provide superior performance, and withstand rugged conditions, while maintaining compatibility with the latest hardware and termination tools. |
- Cables are available with a PVC jacket for in-wall wiring and manufacturing and patch cables, or with a Plenum-rated jacket for needed for use in air returns, drop ceilings, air ducts, conduit, and in pubic establishments with strict building code regulations
- High-performance structured cabling is perfect for a wide range of applications such as 10Base-T, 100Base-TX, 1000Base-TX, Token Ring, TP-PMD, 350 Mbps CDDI, and 622Mps ATM 155
- Exceeds specifications for TIA/EIA 568A, so it can be terminated with most styles of RJ45 keystones and keystone jacks
- CAT 5e cable is rated to 350Mhz to provide outstanding performance and bandwidth over standard rated 100Mhz Cat5e UTP cable
- CAT 6 cable is certified to meet or exceed the 550Mhz (Cat6) and 600Mhz (Cat6a) requirements, ensuring optimal performance and gigabyte speeds
- CM, CMR, and CMP (Plenum-rated cable only) fire rated
- CSA approved
- UL listed
- ETL verified to ANSI/TIE/EIA568A
CAT5e Specs - Performance |
||||||||
Electrical Characteristics: |
Frequency | Return Loss | Attenuation | NEXT | PSNEXT | ELFEXT | PSELFEXT | DELAY |
| (MHz) | (dB) | (dB/100m) | (dB) | (dB) | (dB/100m) | (dB/100m) | (ns/100m) | |
| 1.00 | 20.00 | 2.04 | 65.30 | 62.30 | 64.00 | 61.00 | 570.00 | |
| 4.00 | 23.01 | 4.05 | 56.27 | 53.27 | 48.96 | 48.96 | 552.00 | |
| 8.00 | 24.52 | 5.77 | 51.75 | 48.75 | 42.94 | 42.94 | 546.73 | |
| 10.00 | 25.00 | 6.47 | 50.30 | 47.30 | 41.00 | 41.00 | 545.38 | |
| 16.00 | 25.00 | 8.25 | 47.24 | 44.24 | 36.92 | 36.92 | 543.00 | |
| 20.00 | 25.00 | 9.27 | 45.78 | 42.78 | 34.98 | 34.98 | 542.05 | |
| 25.00 | 24.32 | 10.42 | 44.33 | 41.33 | 33.04 | 33.04 | 541.20 | |
| 31.25 | 23.64 | 11.72 | 42.88 | 39.88 | 31.10 | 31.10 | 540.44 | |
| 62.50 | 21.54 | 16.99 | 38.36 | 35.36 | 24.88 | 24.88 | 538.55 | |
| 100.00 | 20.11 | 21.98 | 35.30 | 32.30 | 21.00 | 21.00 | 537.60 | |
| 200.00 | 18.92 | 32.42 | 30.78 | 27.78 | 14.78 | 14.78 | 537.02 | |
| 250.00 | 17.60 | 36.85 | 29.33 | 26.33 | 12.84 | 12.84 | 536.28 | |
| 350.00 | 16.30 | 44.85 | 27.14 | 24.14 | 9.92 | 9.92 | 535.92 | |
| 1.0 ~ 100.0MH Impedance ( ohms) |
100 ± 15 | |||||||
| 1.0 ~ 100.0MH Delay Skew ( ns/100m) |
<=45 | |||||||
| Pair-to-Ground Capacitance Unbalance ( pF/100m) |
<=330 | |||||||
| Max. Conductor DC Resistance 20ºC ( ohms/km) |
87.66 | |||||||
| Resistance Unbalance ( %) |
<=5 | |||||||
Mechanical Characteristics: |
Test Object | Jacket |
|---|---|---|
| Test Material | PVC | |
| Aging Condition | Before Tensile Strength ( Mpa) | |
| Aging Elongation ( %) | ||
| (ºCxhrs) | ||
| After Tensile Strength ( Mpa) | ||
| Aging Elongation ( %) | ||
Cold Bend ( -20 ± 2 ºCx4hrs )
|
No Crack | |
Marking: |
E198134 UL CMR CAT5e 4PR 24AWG UTP 75ºC---C-UL | |
Description |
Rated Temperature | 75ºC |
| Product Standard Certification | UL File E198134 | |
| Flammability Test | CM/CMR/CMP | |
| Reference Standard | YD/T1019-2001, UL Subject 444, EIA/TIA568 & ISO/IEC 11801 | |
Construction |
Conductor | Solid/Stranded Bare Copper |
| AWG | 24 | |
| Conductor Dia. ( ± 0.005 mm) | 0.485 | |
| Insulation | PE | |
| Average Thickness ( mm) | 0.21 | |
| Min. Point Thickness ( mm) | 0.2 | |
| Insulation Dia. ( ± 0.02 mm) | 0.92 | |
| Twisting Lay Length ( mm) | 30 underneath | |
| Cabling Lay Length ( ± 20 mm) | 100 | |
| Jacket | PVC | |
| Average Thickness ( mm) | 0.45 | |
| Min. Point Thickness ( mm) | 0.43 | |
| Outer Dia. ( ± 0.2 mm) | 4.8 | |
| Weight ( kg/km) | 31.4 | |
Insulation Color |
1st Pair | Blue, White/Blue |
| 2nd Pair | Orange, White/Orange | |
| 3rd Pair | Green, White/Green | |
| 4th Pair | Brown, White/Brown | |
| CAT6 Specs - Performance | ||||||||
| Electrical Characteristics: | Frequency | Return Loss | Attenuation | NEXT | PSNEXT | ELFEXT | PSELFEXT | DELAY |
| (MHz) | (dB) | (dB/100m) | (dB) | (dB) | (dB/100m) | (dB/100m) | (ns/100m) | |
| 1.00 | 20.00 | 2.03 | 74.30 | 72.30 | 67.80 | 64.80 | 570.00 | |
| 4.00 | 23.01 | 3.78 | 65.27 | 63.27 | 55.76 | 52.76 | 552.00 | |
| 10.00 | 25.00 | 5.95 | 59.30 | 57.30 | 47.80 | 44.80 | 545.38 | |
| 16.00 | 25.00 | 7.55 | 56.24 | 54.24 | 43.72 | 40.72 | 543.00 | |
| 20.00 | 25.00 | 8.47 | 54.78 | 52.78 | 41.78 | 38.78 | 542.05 | |
| 25.00 | 24.32 | 9.51 | 53.33 | 51.33 | 39.84 | 36.84 | 541.20 | |
| 31.25 | 23.64 | 10.67 | 51.88 | 49.88 | 37.90 | 34.90 | 540.44 | |
| 62.50 | 21.54 | 15.38 | 47.36 | 45.36 | 31.88 | 28.88 | 538.55 | |
| 100.00 | 20.11 | 19.80 | 44.30 | 42.30 | 27.80 | 24.80 | 537.60 | |
| 200.00 | 18.00 | 28.98 | 39.78 | 37.78 | 21.78 | 18.78 | 536.55 | |
| 250.00 | 17.32 | 32.85 | 38.33 | 36.33 | 19.84 | 16.84 | 536.28 | |
| 350.00 | 16.30 | 39.79 | 36.14 | 34.14 | 16.92 | 13.92 | 535.92 | |
| 550.00 | 14.92 | 51.76 | 33.19 | 31.19 | 12.99 | 9.99 | 535.54 | |
| 1.0 ~ 100.0MH Impedance (ohms) |
100 ± 15 | |||||||
| 100-250MHz Impedance (ohms) |
100 ± 22 | |||||||
| 250-550MHz Impedance (ohms) |
100 ± 25 | |||||||
| 1.0-550.0MHz Delay Skew (ns/100m) |
<=45 | |||||||
| Pair-to-Ground Capacitance Unbalance (pF/100m) |
<=330 | |||||||
| Max. Conductor DC Resistance 20ºC (ohms/km) |
73.2 | |||||||
| Resistance Unbalance (%) | <=5 | |||||||
Mechanical Characteristics: |
Test Object | Jacket | ||||||
|---|---|---|---|---|---|---|---|---|
| Test Material | PVC | |||||||
| Aging Condition | Before Tensile Strength ( Mpa) | >=13.8 | ||||||
| Aging Elongation ( %) | >=100 | |||||||
| (ºCxhrs) | 100x240 | |||||||
| After Tensile Strength ( Mpa) | >=85% Of Unaged | |||||||
| Aging Elongation ( %) | >=50% Of Unaged | |||||||
| Cold Bend ( -20 ± 2 ºCx4hrs) | No Crack | |||||||
Description: |
Flammability Test | CM/CMG/CMP |
|---|---|---|
| Reference Standard | YD/T1019-2001 UL Subject 444,EIA/TIA568 & ISO/IEC 11801;IEC61156-6 | |
Construction: |
Conductor | Solid/Stranded Bare Copper |
| AWG | 23 | |
| Insulation | Polyethylene | |
| Twisting Lay Length ( mm) | 30 underneath | |
| Cabling Lay Length ( ± 20 mm) |
200 | |
| Jacket | PVC | |
| Outer Dia. ( ± 0.2 mm) | 6.2 | |
| Weight ( kg/km) | 41 |
Insulation Color: |
1st Pair | Blue, White/Blue | |||
|---|---|---|---|---|---|
| 2nd Pair | Orange, White/Orange | ||||
| 3rd Pair | Green, White/Green | ||||
| 4th Pair | Brown, White/Brown | ||||
RELATED ARTICLES -
- The Facts on American Wire Gauge (AWG)
- What’s the Difference Between T568A and T568B?
- Using Cat5e and Cat6 Patch Cords
- What's the Difference Between Cat6 and Cat6a?
HOW-TO CORNER -
REVIEW SNAPSHOT®
by PowerReviewsPros
Cons
Best Uses
- Small offices (3)
- Reviewer Profile:
- High bandwidth user (3)
Reviewed by 4 customers
Sort by
Displaying reviews 1-4
Pros
- Highly Compatible
Cons
Best Uses
- Highly Secure Networks
- High Volume
- Home Networks
- Small Offices
Comments about CAT-6 PVC SOLID PVC CABLE:
Excellent Product for a low price.
- Primary use:
- Business
Pros
- Easy to Pull
Cons
Best Uses
- Small Offices
Comments about CAT-6 PVC SOLID PVC CABLE:
Found this cable very easy to pull and had very few kinks out of the box.
- Primary use:
- Business
Pros
- Highly Compatible
Cons
Best Uses
- Home Networks
- Small Offices
Comments about CAT-6 PVC SOLID PVC CABLE:
I have installed several cables made from this spool and have had no problems.
- Primary use:
- Personal
Pros
- Easy To Set Up
Cons
Best Uses
- Highly Secure Networks
- High Volume
Comments about CAT-6 PVC SOLID PVC CABLE:
Great product. Very easy to use in it's packaging. The cable is very easy to strip with the basic UTP stripper/punchdown tool. Amazed with the simplicity! [...]. Very happy!
Displaying reviews 1-4