Home Power & Data Distribution Power Distribution Strips APC Power Distribution Unit
APC Metered & Switched Power Distribution Units (PDU)
Complete Control With Legendary Reliability
![]()
Close Window
APC Metered & Switched Power Distribution Units (PDU)
This requires one or more of the following: javascript enabled, Flash Video Player, and Quicktime or Windows Media Player 7830 | 7862 | 7960 | 7990 |
The APC Metered Rack Power Distribution Unit (PDU) provides power distribution, and, the ability to monitor the aggregate current draw as equipment is connected to the unit. The APC Switched Rack Power Distribution Unit (PDU) is a premium solution to many power management problems, including unauthorized use of power outlets, locked-up equipment, in-rush current, overloaded circuits, and the need of remote access to power outlets in the rack. |
Metered Rack Power Distribution Unit
The APC Metered Rack Power Distribution Unit (PDU) provides power distribution, and, the ability to monitor the aggregate current draw as equipment is connected to the unit. The Metered Rack PDU also has alarm thresholds that will alert users of potential power problems. These features help eliminate the possibility of an overloaded circuit.
Switched Rack Power Distribution Unit
The APC Switched Rack Power Distribution Unit (PDU) is a premium solution to many power management problems, including unauthorized use of power outlets, locked-up equipment, in-rush current, overloaded circuits, and the need of remote access to power outlets in the rack. The Switched Rack PDU addresses these problems through individual outlet control, power on and off delays, current monitoring, alarm thresholds, and network management. Individual outlet control allows users to turn outlets on, turn outlets off, or recycle power to equipment to reboot locked-up equipment and avoid unauthorized use of outlets. Power delays determine the order in which equipment is powered up or down to avoid in-rush current and overloads. Monitoring the current draw at the rack level is key to avoiding downtime due to overloaded circuits. The Switched Rack PDU provides an aggregate current draw, which can be viewed remotely or locally, via digital display. In addition, alarms will be generated based on user-defined thresholds to alert users of potential circuit overloads. Users can access, configure, and control the Switched Rack PDU through Web, SNMP, or Telnet Interfaces.
- Vertical mounting capability takes up 0 RU
- Single input source for more efficiency
- Includes: cord retention brackets, rack mounting brackets, tool-less mounting kit, user manual
- Alarm thresholds for reliable control
- Flash upgradeable
- Meets UL requirements
AP7830 Technical Specifications | AP7862 Technical Specifications | AP7960 Technical Specifications | AP7990 Technical Specifications
AP7830 Specifications
| Part # | PDR-AP7830 |
|---|---|
| Price | |
| Input | |
| Nominal input voltage | 120V |
| Input frequency | 47 - 63 Hz |
| Regulatory Derated Input Current | 16A |
| Input Connection Type | NEMA L5-20P |
| Cord Length | 10 feet |
| Maximum Input Current per phase | 20 A |
| Load Capacity | 1920 VA |
| Physical | |
| Net weight | 15.00 lbs. (6.82 kg) |
| Maximum height | 63.75 inches (1619 mm) |
| Maximum width | 2.19 inches (56 mm) |
| Maximum depth | 1.73 inches (44 mm) |
| Shipping Weight | 17.00 lbs. (7.73 kg) |
| Shipping Height | 84.00 inches (2134 mm) |
| Shipping Width | 6.00 inches (152 mm) |
| Shipping Depth | 5.00 inches (127 mm) |
| Color | Black |
| Environmental | |
| Operating Environment | -5 - 45 °C (23 - 113 °F) |
| Operating Relative Humidity | 0 - 95 % |
| Operating Elevation | 0-10,000 feet (0-3,000 meters) |
| Storage Temperature | -25 - 65 °C (-13 - 149 °F) |
| Storage Relative Humidity | 0 - 95 % |
| Storage Elevation | 0-50,000 feet (0-15,000 meters) |
| Conformance | |
| Approvals | cUL Recognized , FCC Part 15 Class A , ICES-003 , UL 60950 |
| Standard warranty | 2 years repair or replace |
AP7862 Specifications
| Part # | PDR-AP7862 |
|---|---|
| Price | |
| Output | |
| Nominal input voltage | 120V |
| Maximum Total Current Draw per Phase | 16A |
| Output Connections | (42) NEMA 5-20R |
| Input | |
| Nominal input voltage | 208V 3PH |
| Maximum Total Current Draw per Phase | 50/60 Hz |
| Output Connections | NEMA L21-20P |
| Cord Length | 3 feet |
| Maximum Input Current per phase | 16 A |
| Load Capacity | 5700 A |
| Physical | |
| Net weight | 12.00 lbs. (5.45 kg) |
| Maximum height | 70.00 inches (1778 mm) |
| Maximum width | 2.19 inches (56 mm) |
| Maximum depth | 1.73 inches (44 mm) |
| Shipping Weight | 19.50 lbs. (8.86 kg) |
| Shipping Height | 84.00 inches (2134 mm) |
| Shipping Width | 6.00 inches (152 mm) |
| Shipping Depth | 5.00 inches (127 mm) |
| Color | Black |
| Environmental | |
| Operating Environment | 0 - 45 °C (32 - 113 °F) |
| Operating Relative Humidity | 0 - 95% |
| Operating Elevation | 0-10,000 feet (0-3,000 meters) |
| Storage Temperature | -25 - 65 °C (-13 - 149 °F) |
| Storage Relative Humidity | 0 - 95 % |
| Storage Elevation | 0-50,000 feet (0-15,000 meters) |
| Conformance | |
| Approvals | cUL Listed , FCC Part 15 Class A , ICES-003 , UL 60950 , UL Listed |
| Standard warranty | 2 years repair or replace |
AP7960 Specifications
| Part # | PDR-AP7960 |
|---|---|
| Price | |
| Output | |
| Nominal input voltage | 120V |
| Maximum Total Current Draw per Phase | 16A |
| Output Connections | (24) NEMA 5-20R |
| Input | |
| Nominal input voltage | 208V 3PH |
| Input frequency | 50/60 Hz |
| Input Connection Type | NEMA L21-20P |
| Cord Length | 3 feet |
| Maximum Input Current per phase | 16 A |
| Load Capacity | 5700 A |
| Physical | |
| Net weight | 13.00 lbs. (5.91 kg) |
| Maximum height | 63.75 inches (1619 mm |
| Maximum width | 2.19 inches (56 mm) |
| Maximum depth | 1.73 inches (44 mm) |
| Shipping Weight | 15.00 lbs. (6.82 kg) |
| Shipping Height | 84.00 inches (2134 mm) |
| Shipping Width | 6.00 inches (152 mm) |
| Shipping Depth | 5.00 inches (127 mm) |
| Color | Black |
| Environmental | |
| Operating Environment | 0 - 45 °C (32 - 113 °F) |
| Operating Relative Humidity | 5 - 95 % |
| Operating Elevation | 0-10,000 feet (0-3,000 meters) |
| Storage Temperature | -25 - 65 °C (-13 - 149 °F) |
| Storage Relative Humidity | 5 - 95 % |
| Storage Elevation | 0-50,000 feet (0-15,000 meters) |
| Conformance | |
| Approvals | cUL Listed , FCC Part 15 Class A , ICES-003 , UL Listed |
| Standard warranty | 2 years repair or replace |
AP7990 Specifications
| Part # | PDR-AP7990 |
|---|---|
| Price | |
| Output | |
| Output Connections | (24) NEMA 5-20R |
| Input | |
| Nominal input voltage | 208V 3PH |
| Input frequency | 50/60 Hz |
| Input Connection Type | NEMA L21-20P |
| Cord Length | 3 feet |
| Load Capacity | 5700 VA |
| Physical | |
| Net weight | 13.00 lbs. (5.91 kg) |
| Maximum height | 63.75 inches (1619 mm |
| Maximum width | 2.19 inches (56 mm) |
| Maximum depth | 1.73 inches (44 mm) |
| Shipping Weight | 15.00 lbs. (6.82 kg) |
| Shipping Height | 84.00 inches (2134 mm) |
| Shipping Width | 6.00 inches (152 mm) |
| Shipping Depth | 5.00 inches (127 mm) |
| Color | Black |
| Environmental | |
| Operating Environment | 0 - 45 °C (32 - 113 °F) |
| Operating Relative Humidity | 5 - 95 % |
| Operating Elevation | 0-10,000 feet (0-3,000 meters) |
| Storage Temperature | -25 - 65 °C (-13 - 149 °F) |
| Storage Relative Humidity | 5 - 95 % |
| Storage Elevation | 0-50,000 feet (0-15,000 meters) |
| Conformance | |
| Approvals | cUL Listed , FCC Part 15 Class A , ICES-003 , UL Listed |
| Standard warranty | 2 years repair or replace |
| PART # | DESCRIPTION | PRICE |
| PDR-AP7830 | Metered Rack PDU 120V, 20A | |
| PDR-AP7862 | Metered Rack PDU 120V output, 208V - 3PH input | |
| PDR-AP7960 | Switched Rack PDU 120V output, 208V - 3PH input | |
| PDR-AP7990 | Switched Rack PDU 120V output, 208V - 3PH input with 10' Cord |
MANUALS -
- APC Metered Rack PDU Installation Manual (PDF)

- APC Switched Rack PDU Installation Manual (PDF)

- APC AP7830 Manual (PDF)

- APC AP7862 Manual (PDF)

- APC AP7960 Manual (PDF)

- APC AP7990 Manual (PDF)

- Bracket Kit for Vertical Rack PDUs (PDF)

- Deep Toolless Mount Kit (PDF)

RELATED ARTICLES -
- Introduction to Power Distribution and System Grounding
- Integrating Electronic Equipment and Power Into Rack Enclosures (PDF)

HOW-TO CORNER -