Home Racks, Cabinets, Enclosures Enclosures Outdoor Cabinets Rittal CS Outdoor Enclosures
Rittal® CS Pre-Configured Modular Outdoor Enclosures
Quality Outdoor Protection for Electronic, Networking, Control System and Telecommunications Equipment
![]()
Close Window
Rittal CS Pre-Configured Modular Outdoor Enclosures
This requires one or more of the following: javascript enabled, Flash Video Player, and Quicktime or Windows Media Player |
Rittal® CS Pre-Configured Modular Outdoor Enclosures provide a basic setup with plenty of room to grow for future accessories and equipment. These freestanding enclosures utilize welded unibody construction with all-around double-wall aluminum panels for extreme environmental protection and optimum vandalism deterrence. |
- Modular design accommodates a wide range of optional accessories and mounting solutions to facilitate fast, universal interior installation
- Enclosure module utilizes ten-fold profiling for excellent stability and lasting durability
- Side panels, door, base, and rain canopy are screw-fastened and only visible from the inside to deter unwanted access or vandalism
- Double layered aluminum paneling provides all-around solar-shield and heat protection
- Foamed-in-place polyurethane gasket seals off the front door to prevent outside elements and contaminants from penetrating through when closed
- Gas pressurized spring holds the door securely open even in windy conditions to provide increased safety during maintenance and installation
- Flush-mount door latch provides easy and convenient access for authorized personnel, and utilizes a 3-point locking system for increased vandalism protection and security
- Complies with NEMA 3R
- IP 55 to EN 60 529/10.91 Rated

| RL-9751-125 | RL-9751-145 | RL-9752-125 | RL-9751-165 | |
| PRICE | ||||
| Height (H1) | 47.2" | 47.2" | 47.2" | 63.0" |
| Width (B1) | 23.6" | 31.5" | 47.2" | 31.5" |
| Depth (T1) | 23.6" | 19.7" | 23.6" | 23.6" |
| Clearance Height (H2) | 43.8" | 43.8" | 43.8" | 59.5" |
| Clearance Width (B2) | 20.1" | 28.0" | 20.1" | 28.0" |
| Clearance Depth (T2) | 21.8" | 17.9" | 21.8" | 21.8" |
| Rain Canopy Height (H3) | 3.00" | 3.00" | 3.00" | 3.00" |
| Rain Canopy Width (B3) | 27.6" | 35.4" | 51.1" | 35.4" |
| Rain Canopy Depth (T3) | 25.6" | 21.6" | 25.6" | 25.6" |
| Base/Plinth Height (H4) | 3.90" | 3.90" | 3.90" | 3.90" |
| Overall Height (H5) | 54.1" | 54.1" | 54.1" | 69.9" |
Material: |
||||
Enclosure, Roof and Sidewall: |
0.08″ aluminum AlMg3 |
|||
Base/Plinth: |
0.1″ aluminum AlMg3 |
|||
Color: |
RAL 7035 (light gray) |
|||
Protection Category: |
IP 55 to EN 60 529/10.91, NEMA Type 3R |
|||
Configuration: |
Double-walled, fully assembled enclosure, consisting of basic module, roof, sidewalls and base/plinth. |
|||
Patent Information:
- German Patents no. 196 09 699 and 196 09 704
- European Patents no. 0 886 899 and 0 886 900 with validity for FR, IT, GB, SE
- US Patents no. 6,109,053 and 5,971,511
- South Korean Patents No. 0 334 548 and 0 325 930
- Japan Patent no. 3 401 015
Please Allow up to 6-10 Weeks for Delivery
RL-9751-125 Single Door
| PART # | DESCRIPTION | DOOR TYPE | DIMENSIONS | WEIGHT | PRICE |
| RL-9751-125 | Rittal CS PreConfigured Enclosure with Basic Module, Roof, Sidewalls and Base/Plinth | Single | 47.2"H x 23.6"W x 23.6"D | 157 lbs. | |
| RL-9751-125 Accessories | |||||
| RL-9765-083 | Concrete Base/Plinth 23.6" Wide x 23.6" Deep x 39.37" High | 485 lbs. | |||
| RL-9765-092 | Aluminum Mounting plate 23.6" Wide x 47.2" High | 25 lbs. | |||
| RL-7688-000 | 24U Vertical Mounting Angles for Standard 19" Mounting | 7 lbs. | |||
| RL-7696-000 | Rittal Depth Stay Installation Brackets for 19" Mounting Angles in 24" Wide Enclosure | 4 lbs. | |||
| RL-2562-500 | Plastic Gland Plate for IP 65 Cable Entry | 2 lbs. | |||
| RL-2562-100 | PrePunched Metal Gland Plate for Cable Entry | 2 lbs. | |||
| RL-4396-000 | Rittal Slotted Enclosure Support Rails 23.6" | 16 lbs. | |||
| RL-9769-080 | Rittal Enclosure Heater 800W | 2 lbs. | |||
| RL-3110-000 | Rittal Internal Enclosure Thermostat | 1 lbs. | |||
| RL-9765-150 | Rittal Vertical or Horizontal Enclosure Light 48V DC | 2 lbs. | |||
RL-9751-145 Single Door
| PART # | DESCRIPTION | DOOR TYPE | DIMENSIONS | WEIGHT | PRICE |
| RL-9751-145 | Rittal CS PreConfigured Enclosure with Basic Module, Roof, Sidewalls and Base/Plinth | Single | 47.2"H x 31.5"W x 19.7"D | 132 lbs. | |
| RL-9751-145 Accessories | |||||
| RL-9765-084 | Concrete Base/Plinth 31.5" Wide x 19.7" Deep x 39.37" High | 507 lbs. | |||
| RL-9765-095 | Aluminum Mounting plate 31.5" Wide x 47.2" High | 34 lbs. | |||
| RL-7688-000 | 24U Vertical Mounting Angles for Standard 19" Mounting | 7 lbs. | |||
| RL-7698-000 | Rittal Depth Stay Installation Brackets for 19" Mounting Angles in 32" Wide Enclosure | 6 lbs. | |||
| RL-7000-240 | 24U T Slot Vertical Mounting Angles for Standard 19" Mounting | 3 lbs. | |||
| RL-7000-100 | Rittal Depth Stay Installation Bracket for T Slot Metric Angles | 5 lbs. | |||
| RL-2562-500 | Plastic Gland Plate for IP 65 Cable Entry | 2 lbs. | |||
| RL-2562-100 | PrePunched Metal Gland Plate for Cable Entry | 2 lbs. | |||
| RL-4395-000 | Slotted Enclosure Support Rails 19.7" | 12 lbs. | |||
| RL-9769-080 | Rittal Enclosure Heater 800W | 2 lbs. | |||
| RL-3110-000 | Rittal Internal Enclosure Thermostat | 1 lbs. | |||
| RL-9765-150 | Rittal Vertical or Horizontal Enclosure Light 48V DC | 2 lbs. | |||
RL-9751-165 Single Door
| PART # | DESCRIPTION | DOOR TYPE | DIMENSIONS | WEIGHT | PRICE |
| RL-9751-165 | Rittal CS PreConfigured Enclosure with Basic Module, Roof, Sidewalls and Base/Plinth | Single | 63"H x 31.5"W x 23.6"D | 168 lbs. | |
| RL-9751-165 Accessories | |||||
| RL-9765-085 | Concrete Base/Plinth 31.5" Wide x 23.6" Deep x 39.37" High | 551 lbs. | |||
| RL-9765-096 | Aluminum Mounting plate 31.5" Wide x 63" High | 44 lbs. | |||
| RL-7690-000 | 33U Vertical Mounting Angles for Standard 19" Mounting | 9lbs. | |||
| RL-7698-000 | Rittal Depth Stay Installation Brackets for 19" Mounting Angles in 32" Wide Enclosure | 6 lbs. | |||
| RL-7000-330 | 33U T Slot Vertical Mounting Angles for Standard 19"Mounting | 4 lbs. | |||
| RL-7000-100 | Rittal Depth Stay Installation Bracket for T Slot Metric Angles | 5 lbs. | |||
| RL-2562-500 | Plastic Gland Plate for IP 65 Cable Entry | 2 lbs. | |||
| RL-2562-100 | PrePunched Metal Gland Plate for Cable Entry | 2 lbs. | |||
| RL-4396-000 | Rittal Slotted Enclosure Support Rails 23.6" | 16 lbs. | |||
| RL-9769-080 | Rittal Enclosure Heater 800W | 2 lbs. | |||
| RL-3110-000 | Rittal Internal Enclosure Thermostat | 1 lbs. | |||
| RL-9765-150 | Rittal Vertical or Horizontal Enclosure Light 48V DC | 2 lbs. | |||
RL-9752-125 Double Door
| PART # | DESCRIPTION | DOOR TYPE | DIMENSIONS | WEIGHT | PRICE |
| RL-9752-125 | Rittal CS PreConfigured Enclosure with Basic Module, Roof, Sidewalls and Base/Plinth | Double | 47.2"H x 47.2"W x 23.6" D | 182 lbs | |
| RL-9752-125 Accessories | |||||
| RL-9765-087 | Concrete Base/Plinth 47.2" Wide x 23.6" Deep x 39.37" High | 628 lbs. | |||
| RL-9765-191 | Aluminum Mounting plate 47.2" Wide x 47.2" High | 40 lbs. | |||
| RL-7688-000 | 24U Vertical Mounting Angles for Standard 19" Mounting | 7 lbs. | |||
| RL-7696-000 | Rittal Depth Stay Installation Brackets for 19" Mounting Angles in 24" Wide Enclosure | 4 lbs. | |||
| RL-7000-240 | 24U T Slot Vertical Mounting Angles for Standard 19" Mounting | 3 lbs. | |||
| RL-7000-100 | Rittal Depth Stay Installation Bracket for T Slot Metric Angles | 5 lbs. | |||
| RL-2562-500 | Plastic Gland Plate for IP 65 Cable Entry | 2 lbs. | |||
| RL-2562-100 | PrePunched Metal Gland Plate for Cable Entry | 2 lbs. | |||
| RL-4396-000 | Slotted Support Rails 23.6" | 16 lbs. | |||
| RL-9769-080 | Rittal Enclosure Heater 800W | 2 lbs. | |||
| RL-3110-000 | Rittal Internal Enclosure Thermostat | 1 lbs. | |||
| RL-9765-150 | Rittal Vertical or Horizontal Enclosure Light 48V DC | 2 lbs. | |||
Comparison Chart
MANUALS & USER GUIDES -
- CS Outdoor Solutions - Brochure (PDF)

- Thermostat Manual (PDF)

- CS Outdoor Enclosure Specs (PDF)

RELATED ARTICLES -
- Smart and Easy Rack Cable Management with Neat Patch
- Open Racks versus Cabinets
- Setting Up Fiber Optic Technology
- How to Fireproof Your Server Room
HOW-TO CORNER -
- Thermal Management Best Practices - How to Calculate Ventilation Required to Provide an Interior Rack Temperature of 85°F
- How to Prepare for Your Rack System Installation




Facebook Comments