Home > Fire Protection > Water Based Caulks > Fire Barrier CP 25WB+Caulk
3M™ Fire Barrier CP 25WB+ Caulk
Intumescent Latex Caulk Seals Out Fire, Water, Smoke, and Noxious Gases
![]()
3M Fire Barrier CP 25WB+ Caulk
This requires one or more of the following: javascript enabled, Flash Video Player, and Quicktime or Windows Media Player |
What's special about this caulk?
3M™ Fire Barrier CP 25WB+ Caulk is a premium elastomeric latex caulk designed for use as a one-part fire, smoke, noxious gas and water sealant. In addition, the unique intumescent property of this material (expands when heated) means that as cable or pipe insulation is consumed by fire, CP 25WB+ Caulk expands to maintain the penetration seal. |
- Halogen-free
- Fast dry : Tack-free in approximately 10-15 minutes
- Paintable (Best results obtained after 72 hour cure)
- Minimal shrinkage
- Brown color
- Water seal: Seals against inadvertent water spills in the unexpanded state
- High caulk rate: 1000 g/min. with in. nozzle
- Point contact allowed
- Continuous Operating Temperature not to exceed 120°F (48°C)
- Made in the USA
CP 25WB+ Caulk features superior adhesion strength, caulk rate and no sag application with expanded UL Classified fire protection systems plus a halogen-free formula.
3M Fire Barrier CP 25WB+ Caulk can be installed with a standard caulking gun, pneumatic pumping equipment or it can be easily applied with a putty knife or trowel. CP 25WB+ Caulk will bond to concrete, metals, wood, plastic and cable jacketing. No mixing is required.
Applications
Use to seal construction openings, blank openings and penetrating items against the passage of flame, noxious gas, smoke and water. Restores fire rated construction to original integrity. Also for use with 3M Brand Fire Barrier FS195+ Wrap/Strip and CS-195+ Composite Sheet.

FILL, VOID OR CAVITY MATERIALS FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS.
SEE UL DIRECTORY OF PRODUCTS CERTIFIED FOR CANADA AND UL FIRE RESISTANCE DIRECTORY 50L6.
Product
The firestopping caulk shall be a one-part, intumescent, latex elastomer. The caulk shall be capable of expanding a minimum of 3 times at 1000°F. The material shall be thixotropic and be applicable to overhead, vertical and horizontal firestops. The caulk shall be listed by independent test agencies such as UL or FM and be tested to, and pass the criteria of, ASTM E 814 Fire Test, tested under positive pressure. It shall comply with the requirements of the NEC (NFPA-70), BOCA, ICBO, SBCCI and NFPA Code #101.
| Typically Specified Divisions | |
|---|---|
| Division 7 07270 |
Thermal and Moisture Protection Firestopping |
| Division 13 13900 |
Special Construction Fire Suppression and Supervisory Systems |
| Division 15 15250 15300 |
Mechanical Mechanical Insulation Fire Protection |
| Division 16 Electrical 16050 |
Electrical Basic Electrical Materials and Methods |
| Performance | ||
| Unit | Value | |
Tack Free Time (ASTM C679-87) |
Minutes at 72°F (22°C) | 10-15 |
Expansion at 662°F (350°C) |
X | 2.0-3.0 |
Color |
– | Reddish Brown |
Density |
Lb./gal. (Kg/l) | 11.2 (1,35) |
Adhesion |
All construction substrates | Very Good |
Application |
Method | Caulk guns, trowel, spatula pressurized pumps |
Durometer (hardness) |
Shore A | 70 |
ASTM E 84 |
– – |
5 0 |
Solids |
Percent (%) by weight | 79 |
VOC |
Percent (%) by weight | 0 |
Odor |
– | Pleasant, non-irritating |
Flow Rate 1/4 in. (6,35 mm) nozzle at 50 psi |
Grams/min. | 1000 |
Boeing Flow (Sag Characteristics) |
Inches | 0 |
Firestopping Properties
Meets the criteria of ASTM E 814 Fire Test, tested under positive pressure.
Consult current UL Fire Resistance Directory for systems listed under 3M Product CP 25WB+ Caulk.
Firestopping Code Requirements
| ICBO Uniform Building Code (1997 Edition) |
SBCCI Standard Building Code (1997 Edition) |
BOCA Basic/National Building Code(1996 Edition) | NFPA Life Safety Code 101 (1997 Edition) | |
702 |
104.2.4 PLANS MUST SHOW HOW INTEGRITY IS MAINTAINED FOR ASSEMBLIES PENETRATED 202 DEFINITIONS 705.3 WOOD FRAME CONSTRUCTION FIREBLOCKING 705.3.1.5 CURTAIN WALL GAP 705.4 (GENERAL) PENETRATIONS OF FIRE RATED ASSEMBLIES 705.5 (WALLS) 705.6 (FLOORS) 705.7 FIRE RESISTANT JOINT SYSTEMS |
702.0 REVISED AND EXPANDED DEFINITIONS FOR PENETRATIONS AND JOINTS 703.1 CONSTRUCTION DOCUMENTS SHALL INDICATE DETAILS AND MATERIALS FOR PROVIDING RATINGS AT JOINTS AND PENETRATIONS 703.1.1 PENETRATIONS AND JOINTS SHALL NOT BE CONCEALED FROM VIEW BEFORE INSPECTION 703.2 BUILDINGS FOR MORE THAN TWO STORIES SHALL INDICATE ALL PENETRATIONS 704.1.1 SUFFICIENT DATA SHALL BE AVAILABLE TO JUSTIFY UNTESTED MATERIALS USED FOR RESTORATION OF FIRE RATINGS 707.0 FIRE WALLS AND PARTY WALLS 707.10 PENETRATIONS - REFERS TO 714 707.8 JOINTS - REFERS TO 709.7 709.0 FIRE SEPARATION ASSEMBLIES |
709.6 PENETRATIONS - REFER TO 714 709.7 JOINTS 711.0 FIRE PARTITIONS 711.6 PENETRATIONS - REFERS TO 714 711.7 JOINTS - REFER TO 709.7 713.0 FLOOR/CEILING AND ROOF/CEILING ASSEMBLIES 713.2 CURTAIN WALL GAP 713.4 PENETRATIONS - REFERS TO 714 713.5 JOINTS - REFERS TO 709.7 714.0 PENETRATIONS - ALL REQUIREMENTS (GENERAL) 714.1 THROUGH 714.1.6.2 WALL ASSEMBLIES 714.2 THROUGH 714.2.6.5 FLOOR/CEILING AND ROOF/CEILING ASSEMBLIES 714.3 THROUGH 714.3.2 NONRATED ASSEMBLIES 721.0 FIREBLOCKING AND DRAFTSTOPPING |
6-2.3.2.4 PENETRATIONS AND MISC. OPENINGS&FIRE BARRIERS 6.2.4.2, EXCEPTION 5 OPENINGS (EXPANSION OR SEISMIC JOINTS) IN FLOORS APPENDIX A-6-2.4.2 6-3.6.1 PENETRATIONS AND MISC. OPENINGS IN FLOORS AND SMOKE BARRIERS NFPA #221 FIRE WALLS AND |
NFPA
|
||||
CABO |
||||

FILL, VOID OR CAVITY MATERIALS FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS.
SEE UL DIRECTORY OF PRODUCTS CERTIFIED FOR CANADA AND UL FIRE RESISTANCE DIRECTORY 50L6.
Please Note: There is a 5 Day Lead Time on orders for Pails.
| PART # | PACKAGE SIZE | USAGE | PRICE |
| FP-3M-CP25WB-T | 10.1 oz. Tube | Lightweight easy to handle. Perfect for smaller jobs. | |
| FP-3M-CP25WB-P | 5 gallon Pail | Great for bulk loading on large jobs. The most cost-effective way to caulk large areas. |
|
Installation Techniques
Warranty and Limited Remedy Warranty and Limited Remedy Limitation of Liability |
RELATED ARTICLES -
- Creating a Fire Protection Plan for Your Business
- Which Firestop Product Should I Use for My Application?
- CableOrganizer.com’s Top 10 Products for Fire Protection
- How to Fireproof Your Server Room
- History of 3M Corporation